Optimal timing of contrast-enhanced three-dimensional magnetic resonance left atrial angiography before pulmonary vein ablation

被引:5
|
作者
Loebe, Susanne [1 ]
Leuthaeusser, Claudia [1 ]
Poelkow, Alexander [1 ]
Hilbert, Sebastian [1 ]
Sommer, Philipp [1 ]
Bollmann, Andreas [1 ]
Hindricks, Gerhard [1 ,2 ]
Paetsch, Ingo [1 ]
Jahnke, Cosima [1 ]
机构
[1] Univ Leipzig, HELIOS Heart Ctr Leipzig, Dept Electrophysiol, Struempellstr 39, D-04289 Leipzig, Germany
[2] Leipzig Heart Inst, Leipzig, Germany
关键词
cardiovascular magnetic resonance imaging; angiography; pulmonary vein; atrial fibrillation; catheter ablation; CATHETER ABLATION; ECHOCARDIOGRAPHIC-ASSESSMENT; EUROPEAN ASSOCIATION; FIBRILLATION;
D O I
10.5603/CJ.a2019.0112
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: To achieve high image quality of cardiovascular magnetic resonance (CMR) pulmonary vein (PV) angiography prior catheter ablation in patients with atrial fibrillation, optimal timing of the angiographic sequence during contrast agent passage is important. The present study identified influential cardiovascular parameters for prediction of contrast agent travel time. Methods: One hundred six consecutive patients underwent a CMR examination including three-dimensional (3D) contrast-enhanced PV angiography with real-time bolus tracking prior to catheter ablation. Correct scan timing was characterized by relative signal enhancement measurements in the pulmonary artery, left atrium (LA), and ascending aorta. Furthermore, left- and right-ventricular function, left- and right-atrial dimensions, presence of mitral or tricuspid insufficiencies, and main pulmonary artery diameter were determined. Results: The highest relative signal enhancement in LA demonstrated optimal scan timing. Contrast agent travel time showed wide variability (range: 12-42 s; mean: 18 +/- 4 s). On univariate analysis, most cardiovascular parameters correlated with contrast agent travel time while on multivariate analysis left- and right-ventricular function remained the only independent predictors, but overall a poor fit to the data (adjusted R-2, 27.5%) was found. Conclusions: Contrast agent travel time was mainly influenced by left- and right-ventricular function but prediction models poorly fitted the data. Thus, 3D PV angiography prior to PV ablation procedures necessitates real-time assessment, with visual determination of individual contrast agent passage time to ensure consistently high CMR image quality.
引用
收藏
页码:558 / 565
页数:8
相关论文
共 50 条
  • [1] Pulmonary vein and left atrial invasion by lung cancer: Assessment with contrast-enhanced three-dimensional MR angiography
    Takahashi, K
    Kamishima, T
    Furuse, M
    Satoh, S
    Saitoh, K
    Aburano, T
    RADIOLOGY, 1998, 209P : 451 - 451
  • [2] Three-dimensional contrast-enhanced magnetic resonance angiography of the thoracic vasculature
    Leung, DA
    Debatin, JF
    EUROPEAN RADIOLOGY, 1997, 7 (07) : 981 - 989
  • [3] Contrast-enhanced three-dimensional magnetic resonance angiography of the mesenteric vasculature
    Baden, JG
    Racy, DJ
    Grist, TM
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 10 (03): : 369 - 375
  • [4] Three-dimensional contrast-enhanced magnetic resonance angiography of the thoracic vasculature
    D. A. Leung
    J. F. Debatin
    European Radiology, 1997, 7 : 981 - 989
  • [5] Three-dimensional contrast-enhanced magnetic resonance angiography in a patient with chronic thromboembolic pulmonary hypertension before and after thromboendarterectomy
    Kreitner, KF
    Mayer, E
    Voigtlaender, T
    Thelen, M
    Oelert, H
    CIRCULATION, 1999, 99 (08) : 1101 - 1101
  • [6] Three-dimensional contrast-enhanced magnetic resonance angiography of the pulmonary artery in congenital cardiovascular defects
    Kondo, C
    Sakal, F
    Takada, K
    Yokoyama, U
    Momma, K
    CIRCULATION, 1999, 100 (18) : 394 - 394
  • [7] Pulmonary vein diameter reduction after radiofrequency catheter ablation for paroxysmal atrial fibrillation evaluated by contrast-enhanced three-dimensional magnetic resonance Imaging
    Dill, T
    Neumann, T
    Ekinci, O
    Breidenbach, C
    John, A
    Erdogan, A
    Bachmann, G
    Hamm, CW
    Pitschner, HF
    CIRCULATION, 2003, 107 (06) : 845 - 850
  • [8] Pulmonary vein diameter reduction after radiofrequency catheter ablation for paroxysmal atrial fibrillation evaluated by contrast-enhanced three-dimensional magnetic resonance imaging
    Anselme, F
    Savouré, A
    Gerbaud, E
    Gahide, G
    Cribier, A
    Dacher, JN
    EUROPEAN HEART JOURNAL, 2004, 25 : 147 - 147
  • [9] Three-dimensional demonstration of the artery of Adamkiewicz with contrast-enhanced magnetic resonance angiography
    Yoshioka, K
    Niinuma, H
    Kawakami, T
    Nakajima, T
    Kawazoe, K
    Ehara, S
    ANNALS OF THORACIC SURGERY, 2005, 79 (05): : 1785 - 1785
  • [10] Three-dimensional contrast-enhanced magnetic resonance angiography of the abdominal arterial system
    Leung, DA
    Hany, TF
    Debatin, JF
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 21 (01) : 1 - 10