Development of a new palpation method using alternative landmarks for the determination of thoracic transverse processes: An in vitro study

被引:6
|
作者
Page, Isabelle [1 ,3 ]
Descarreaux, Martin [2 ,3 ]
Sobczak, Stephane [1 ,3 ]
机构
[1] Univ Quebec Trois Rivieres, Dept Anat, 3351 Boul Forges,CP 500, Trois Rivieres, PQ G9A 5H7, Canada
[2] Univ Quebec Trois Rivieres, Dept Sci Activite Phys, 3351 Boul Forges,CP 500, Trois Rivieres, PQ G9A 5H7, Canada
[3] Univ Quebec Trois Rivieres, GRAN, 3351 Boul Forges,CP 500, Trois Rivieres, PQ G9A 5H7, Canada
基金
加拿大健康研究院;
关键词
Thoracic spine; Palpation; Transverse process; Validity; SPINOUS PROCESSES; SPINAL LEVELS; THIEL; IDENTIFICATION; ACCURACY; LEVEL; MODEL; SITE;
D O I
10.1016/j.math.2016.09.005
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Palpation methods (PMs) have been proposed to guide clinicians in locating the thoracic transverse processes (TTPs). However, no studies have assessed the validity of TTPs palpation or the added value of musculoskeletal ultrasound (MSU). The objectives of the present study were (1) to explore the validity of TTPs location using palpation as commonly performed by clinicians, (2) to develop an accurate and valid PM, and (3) to assess the added value of MSU. A standardized procedure was used on six cadavers. It consisted in the insertion of markers through the T3, T5, T6 and T8 TTPs and spinous processes, which were identified using palpation and MSU. First, a fresh cadaver was used to explore the validity of the common palpation method. Since poor validity was observed, one intermediate and a final PMs were tested on a total of five Thiel-embalmed specimens. A descriptive analysis was performed and agreement between MSU and the final PM was determined. The final PM led to the proper determination of all TTPs on three specimens with a mean error of 4 +/- 1.8 mm in relation to the TTPs center. The coefficient of variations and root mean square errors were <= 0.15 and 0.21 mm, respectively. Bland-Altman plot showed no differences between palpation and MSU. In conclusion, this study reports the validity of a new PM using multiple landmarks to guide TTPs determination and for which MSU does not seem to add value in accuracy. These results may have important clinical implications for clinicians using palpation. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:142 / 149
页数:8
相关论文
共 50 条
  • [21] Development of a new method for the enantiomer specific determination of HBCD using an ion trap mass spectrometer
    Gomara, Belen
    Lebron-Aguilar, Rosa
    Quintanilla-Lopez, Jesus Eduardo
    Jose Gonzalez, Maria
    ANALYTICA CHIMICA ACTA, 2007, 605 (01) : 53 - 60
  • [22] Development and Validation of a New Analytical Method for the Determination of Related Components in Tolterodine Tartarate Using LC
    A. Madhavi
    G. S. Reddy
    M. V. Suryanarayana
    A. Naidu
    Chromatographia, 2008, 68 : 399 - 407
  • [23] Numerical Simulation Study on the Microphysical Processes of Typhoon Wipha Using a New Moisture Conditioning Method
    Yang, Wenxia
    Hu, Zhaoxia
    Lei, Hengchi
    Li, Baodong
    JOURNAL OF COASTAL RESEARCH, 2020, : 156 - 159
  • [24] The development of a new method for the determination of concentrations of carbonaceous gases using a non-dispersive infrared sensor
    Liu, Haibo
    Chen, Tianhu
    Chen, Dong
    Chang, Dongyin
    Frost, Ray L.
    FUEL, 2013, 104 : 749 - 751
  • [25] Development of a new chromatographic method for the determination of antidepressants in human plasma using microextraction by packed sorbent (MEPS®)
    Regenjo Vazquez, M.
    Carro Diaz, A. M.
    Lorenzo Ferreira, R. A.
    Alvarez Freire, I.
    Fernandez Gomez, P.
    TOXICOLOGY LETTERS, 2015, 238 (02) : S154 - S154
  • [26] SERUM ISOAMYLASES DETERMINATION - ANALYTICAL AND CRITICAL-STUDY OF A NEW METHOD USING AN INHIBITOR PROTEIN
    BENOIT, MO
    JAFFRAY, P
    CAILLENS, H
    SOUCIET, C
    EKINDJIAN, OG
    DOURIS, RG
    PATHOLOGIE BIOLOGIE, 1981, 29 (04): : 223 - 228
  • [27] ALKALINE HEMATIN D-575, A NEW TOOL FOR THE DETERMINATION OF HEMOGLOBIN AS AN ALTERNATIVE TO THE CYANHEMIGLOBIN METHOD .2. STANDARDIZATION OF THE METHOD USING PURE CHLOROHEMIN
    WOLF, HU
    LANG, W
    ZANDER, R
    CLINICA CHIMICA ACTA, 1984, 136 (01) : 95 - 104
  • [28] A new method for the study of processes at the liquid-liquid interface using an array of microdroplets on a Au electrode
    Simm, Andrew O.
    Chevallier, Francois G.
    Ordeig, Olga
    del Campo, F. Javier
    Munoz, Francesc X.
    Compton, Richard G.
    CHEMPHYSCHEM, 2006, 7 (12) : 2585 - 2592
  • [29] Accuracy of full-arch scans using intraoral and extraoral scanners: an in vitro study using a new method of evaluation
    Muallah, J.
    Wesemann, C.
    Nowak, R.
    Robben, J.
    Mah, J.
    Pospiech, P.
    Bumann, A.
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2017, 20 (02) : 151 - 164
  • [30] A new tractable method for generating human alveolar macrophage-like cells in vitro to study lung inflammatory processes and diseases
    Pahari, Susanta
    Arnett, Eusondia
    Simper, Jan
    Azad, Abul
    Guerrero-Arguero, Israel
    Ye, Chengjin
    Zhang, Hao
    Cai, Hong
    Wang, Yufeng
    Lai, Zhao
    Jarvis, Natalie
    Lumbreras, Miranda
    Maselli, Diego Jose
    Peters, Jay
    Torrelles, Jordi B. B.
    Martinez-Sobrido, Luis
    Schlesinger, Larry S. S.
    MBIO, 2023, 14 (04): : e0083423