Development of a new palpation method using alternative landmarks for the determination of thoracic transverse processes: An in vitro study

被引:6
|
作者
Page, Isabelle [1 ,3 ]
Descarreaux, Martin [2 ,3 ]
Sobczak, Stephane [1 ,3 ]
机构
[1] Univ Quebec Trois Rivieres, Dept Anat, 3351 Boul Forges,CP 500, Trois Rivieres, PQ G9A 5H7, Canada
[2] Univ Quebec Trois Rivieres, Dept Sci Activite Phys, 3351 Boul Forges,CP 500, Trois Rivieres, PQ G9A 5H7, Canada
[3] Univ Quebec Trois Rivieres, GRAN, 3351 Boul Forges,CP 500, Trois Rivieres, PQ G9A 5H7, Canada
基金
加拿大健康研究院;
关键词
Thoracic spine; Palpation; Transverse process; Validity; SPINOUS PROCESSES; SPINAL LEVELS; THIEL; IDENTIFICATION; ACCURACY; LEVEL; MODEL; SITE;
D O I
10.1016/j.math.2016.09.005
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Palpation methods (PMs) have been proposed to guide clinicians in locating the thoracic transverse processes (TTPs). However, no studies have assessed the validity of TTPs palpation or the added value of musculoskeletal ultrasound (MSU). The objectives of the present study were (1) to explore the validity of TTPs location using palpation as commonly performed by clinicians, (2) to develop an accurate and valid PM, and (3) to assess the added value of MSU. A standardized procedure was used on six cadavers. It consisted in the insertion of markers through the T3, T5, T6 and T8 TTPs and spinous processes, which were identified using palpation and MSU. First, a fresh cadaver was used to explore the validity of the common palpation method. Since poor validity was observed, one intermediate and a final PMs were tested on a total of five Thiel-embalmed specimens. A descriptive analysis was performed and agreement between MSU and the final PM was determined. The final PM led to the proper determination of all TTPs on three specimens with a mean error of 4 +/- 1.8 mm in relation to the TTPs center. The coefficient of variations and root mean square errors were <= 0.15 and 0.21 mm, respectively. Bland-Altman plot showed no differences between palpation and MSU. In conclusion, this study reports the validity of a new PM using multiple landmarks to guide TTPs determination and for which MSU does not seem to add value in accuracy. These results may have important clinical implications for clinicians using palpation. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:142 / 149
页数:8
相关论文
共 50 条
  • [1] A new model to facilitate palpation of the level of the transverse processes of the thoracic spine
    Geelhoed, Michael A.
    McGaugh, Janna
    Brewer, Patricia A.
    Murphy, Douglas
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2006, 36 (11): : 876 - 881
  • [2] DEVELOPMENT OF A NEW METHOD FOR THE DETERMINATION OF ARSENIC IN BABY FORMULAS BY USING EXTRACTION METHOD
    Gundogdu, Omer
    Ay, Umit
    FRESENIUS ENVIRONMENTAL BULLETIN, 2013, 22 (12): : 3584 - 3587
  • [3] A novel and alternative in vitro method using microwave to study the epithelial-stromal interactions
    Alejandra Sacca, Paula
    Pistone Creydt, Virginia
    Julieta Tesone, Amelia
    Carlos Calvo, Juan
    SCIENTIFIC RESEARCH AND ESSAYS, 2009, 4 (12): : 1487 - 1495
  • [4] A method for determination of equine hoof strain patterns using photoelasticity:: an in vitro study
    Dejardin, LM
    Arnoczky, SP
    Cloud, GL
    EQUINE VETERINARY JOURNAL, 1999, 31 (03) : 232 - 237
  • [5] In vitro determination of disintegration time of quick-dissolve tablets using a new method
    Dor, PJM
    Fix, JA
    PHARMACEUTICAL DEVELOPMENT AND TECHNOLOGY, 2000, 5 (04) : 575 - 577
  • [6] In vitro degradation study of polyester microspheres by a new HPLC method for monomer release determination
    Giunchedi, P
    Conti, B
    Scalia, S
    Conte, U
    JOURNAL OF CONTROLLED RELEASE, 1998, 56 (1-3) : 53 - 62
  • [7] Development of an Alternative Socket Fabrication Method Using Hydrostatic Cast System: A Preliminary Study
    Shikh, S. S. Syed
    Abu Osman, N. A.
    Latif, L. Abdul
    4TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2008, VOLS 1 AND 2, 2008, 21 (1-2): : 766 - +
  • [8] A new method to validate thoracic CT-CT deformable image registration using auto-segmented 3D anatomical landmarks
    Nielsen, Martin S.
    Ostergaard, Lasse R.
    Carl, Jesper
    ACTA ONCOLOGICA, 2015, 54 (09) : 1515 - 1520
  • [9] Preliminary study of an in vitro development of new tissue applying mechanical stimulation with a bioreactor as an alternative for ligament reconstruction
    Bourdon-Santoyo, Marlene
    Quinones-Uriostegui, Ivett
    Martinez-Lopez, Valentin
    Sanchez-Arevalo, Francisco
    Alessi-Montero, Aldo
    Velasquillo, Cristina
    Ibarra-Ponce de Leon, Clemente
    REVISTA DE INVESTIGACION CLINICA-CLINICAL AND TRANSLATIONAL INVESTIGATION, 2014, 66 : S100 - S110
  • [10] Accuracy of thoracic pedicle screw placement in adolescent idiopathic scoliosis patients using the entry point identified by new landmarks: a computed tomography study
    Jun Jiang
    Xu Chen
    Yong Qiu
    Bin Wang
    Ze-zhang Zhu
    Yang Yu
    BMC Surgery, 22