Computational analysis of spray type counter flow liquid desiccant dehumidifier

被引:0
|
作者
Ahmed, M. Ijas [1 ]
Vignesh, R. [1 ]
Kumar, L. Gangadhara Kiran [1 ]
机构
[1] NIT Calicut, Dept Mech Engn, Calicut 673601, Kerala, India
关键词
Liquid desiccant; 3D model; Spray type; Counter flow; Mass transfer; PERFORMANCE;
D O I
10.1016/j.matpr.2020.10.888
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The liquid desiccant air conditioning system (LDAC) is considered as the substitute for the conventional air conditioning system mainly because of its energy-saving characteristics. The dehumidifier is one of the most important components in LDAC, therefore, it is chosen as the system for analysis. A 3D computational model of the spray type dehumidifier with counter flow configuration was created and analysed its mass transfer characteristics for two different cases. 2D CFD models studied by various researchers failed to elaborate on the actual flow process. In order to fill this gap 3D model was created and the analysis was conducted to investigate the influence of flow rate of air and desiccant on the mass transfer performance of the dehumidifier. Air and desiccant flow rate have direct influence on the mass transfer performance of the dehumidifier. In this study, the dehumidification performance is evaluated through the simulation by increasing the desiccant flow rate and simultaneously reducing the airflow rate and the results are observed. ANSYS-FLUENT (R) software is used for the current analysis. The increase in desiccant flow rate and decrease in air flow rate tends to improve the change in humidity ratio (specific moisture removal) from 4.2 to 6.3 g/kg of dry air. The temperature variation of solution keeps increasing as the moisture transfer increases. The rise in temperature of the solution is higher than the air during moisture transfer due to exothermic process. Similarly the equilibrium humidity ratio of solution increased due to moisture absorption during dehumidification, which indicates the decrease in solution concentration during dehumidification. The heating of solution and air during dehumidification will affect the moisture transfer rate, which can be avoided by adding a cooling unit to the liquid desiccant system. (c) 2019 Elsevier Ltd. Selection and Peer-review under responsibility of the scientific committee of the International Mechanical Engineering Congress 2019: Materials Science.
引用
收藏
页码:9820 / 9826
页数:7
相关论文
共 50 条
  • [1] Thermodynamic analysis of a counter flow adiabatic dehumidifier with different liquid desiccant materials
    Koronaki, I. P.
    Christodoulaki, R. I.
    Papaefthimiou, V. D.
    Rogdakis, E. D.
    APPLIED THERMAL ENGINEERING, 2013, 50 (01) : 361 - 373
  • [2] An experimental study on the dehumidification performance of a counter flow liquid desiccant dehumidifier
    Wang, Lingshi
    Xiao, Fu
    Zhang, Xuejun
    Kumar, Ritunesh
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 70 : 289 - 301
  • [3] Experimental investigation and performance analysis of a spray-type ionic liquid desiccant dehumidifier
    Liang, Jyun-De
    Kao, Chia-Lin
    Chen, Chih-Hao
    Ho, Hong-Yi
    Huang, Chih-Hsueh
    Chen, Sih-Li
    APPLIED THERMAL ENGINEERING, 2024, 254
  • [4] Performance of a proposed complete wetting surface counter flow channel type liquid desiccant air dehumidifier
    Hassan, M. Salah
    Hassan, A. A. M.
    RENEWABLE ENERGY, 2009, 34 (10) : 2107 - 2116
  • [5] Dynamic and microscopic simulation of the counter-current flow in a liquid desiccant dehumidifier
    Luo, Yimo
    Yang, Hongxing
    Lu, Lin
    APPLIED ENERGY, 2014, 136 : 1018 - 1025
  • [6] CFD simulation of the liquid flow on structured packing in the liquid desiccant dehumidifier
    Luo, Yimo
    Yang, Hongxing
    Lu, Lin
    INTERNATIONAL CONFERENCE ON APPLIED ENERGY, ICAE2014, 2014, 61 : 180 - 183
  • [7] Dynamic Analysis of Mass Transfer in a Liquid Desiccant Dehumidifier
    Wu, Qiong
    Cai, Wenjian
    Wang, Xinli
    Wang, Lei
    PROCEEDINGS OF THE 2015 10TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, 2015, : 28 - 33
  • [8] Macroscopic parameters investigation and transfer characteristics assessment of counter flow packed tower liquid desiccant dehumidifier/regenerator
    Nandkishor S. Deshmukh
    Bajirao S. Gawali
    B. Kiran Naik
    Mahmadrafik S. Choudhari
    Rustum S. Dhalait
    Heat and Mass Transfer, 2023, 59 : 1185 - 1207
  • [9] Macroscopic parameters investigation and transfer characteristics assessment of counter flow packed tower liquid desiccant dehumidifier/regenerator
    Deshmukh, Nandkishor S.
    Gawali, Bajirao S.
    Naik, B. Kiran
    Choudhari, Mahmadrafik S.
    Dhalait, Rustum S.
    HEAT AND MASS TRANSFER, 2023, 59 (07) : 1185 - 1207
  • [10] Analysis of parallel flow type internally cooled membrane based liquid desiccant dehumidifier using neural networks approach
    Quadros, Jaimon Dennis
    Khan, S. A.
    Prashanth, T.
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2022, 28 (03) : 403 - 421