Expanded polytetrafluoroethylene (Gore-Tex) augmentation of deep nasolabial creases

被引:4
|
作者
Robertson, KM [1 ]
Dyer, WK [1 ]
机构
[1] Univ Wisconsin, Div Otolaryngol, Madison, WI 53792 USA
关键词
D O I
10.1001/archotol.125.4.456
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective: To evaluate the safety and efficacy of expanded polytetrafluoroethylene (PTFE) (Gore;Tex; W. L. Gore & Associates, Flagstaff, Ariz) for augmentation of deep nasolabial creases. Design: Retrospective chart review with a minimum of IZ months of follow-up. Setting: Private practice ambulatory surgery center. Study Population: One hundred consecutive patients (average age, 49 years) undergoing expanded PTFE augmentation of the nasolabial crease. Main Outcome Measures: A standardized, reproducible rating scale assessed preoperative crease severity. Clinical effectiveness was determined by the numerical degree of improvement in crease severity rating after surgery, and by the number of procedures required to achieve the desired aesthetic results. Results: Patients initially had grade 1 (14.5%), grade 2 (54.0%), grade 3 (20.0%), or grade 4 (11.5%) crease severity ratings. On average, patients with grade I creases required 1.17 total augmentation procedures, those with grade 2 required 1.60, those with grade 3 required 1.93, and those with grade 4 required 1.86. On average, with each augmentation, patients with grade I improved 0.61 relative severity points; those with grade 2, 0.85; those with grade 3, 1.29; and those with grade 4, 1.28. Nine patients developed late postoperative sequelae. Four creases (2.0%) displayed an unnatural mounded appearance because of superficial expanded PTFE placement. All 4 creases underwent elective removal of a single superficial PTFE strip, with resultant return of aesthetically correct crease augmentation. Five creases (2.5%) developed implant site infections; in all 5 cases, the involved strips were removed and the infection was resolved with a 10-day course of oral antibiotics; Conclusions: Expanded PTFE augmentation presents a safe, effective method for softening deep nasolabial creases. Patients with more severe creases are likely to show more improvement with each augmentation, but are also more likely to require multiple procedures to achieve the desired aesthetic result.
引用
收藏
页码:456 / 461
页数:6
相关论文
共 50 条
  • [21] GORE-TEX FOR NASAL AUGMENTATION - REPLY
    DANIEL, RK
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1995, 96 (01) : 229 - 229
  • [22] AXILLOFEMORAL BYPASS WITH GORE-TEX PROSTHESIS (POLYTETRAFLUOROETHYLENE)
    AZZENA, G
    DURANTE, E
    SANTINI, A
    MINERVA CARDIOANGIOLOGICA, 1980, 28 (06): : 453 - 456
  • [23] X-ray changes after expanded polytetrafluoroethylene (Gore-Tex) interpositional arthroplasty
    Greenberg, JA
    Mosher, JF
    Fatti, JF
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1997, 22 (04): : 658 - 663
  • [24] Inferior alveolar nerve regeneration via expanded-polytetrafluoroethylene (Gore-Tex) entubulation
    Miloro, M
    Macy, J
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 2311 - 2311
  • [25] FALSE ANEURYSM OF THE ASCENDING AORTA FROM AN EXPANDED POLYTETRAFLUOROETHYLENE (GORE-TEX) AORTOPULMONARY SHUNT
    EVANS, VL
    HALLMAN, GL
    VARGO, TA
    GUTGESELL, HP
    ANNALS OF THORACIC SURGERY, 1985, 39 (06): : 573 - 575
  • [26] COMPLICATIONS FOLLOWING LIP AUGMENTATION WITH GORE-TEX
    WOLF, DL
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1995, 95 (07) : 1334 - 1334
  • [27] Histopathology of polytetrafluoroethylene (Gore-tex) as a scleral buckle in humans
    Sheu, SJ
    Chou, LC
    Lee, IY
    Wang, CC
    OPHTHALMIC SURGERY AND LASERS, 2001, 32 (03): : 245 - 247
  • [28] Gore-tex® augmentation grafting in rhinoplasty -: Is it safe?
    Mendelsohn, M
    Dunlop, G
    JOURNAL OF OTOLARYNGOLOGY, 1998, 27 (06): : 337 - 341
  • [29] ALLOPLASTIC REPLACEMENT OF CANINE URETER BY EXPANDED POLYTETRAFLUOROETHYLENE (GORE-TEX) GRAFTS - PRELIMINARY-REPORT
    DREIKORN, K
    LOBELENZ, J
    HORSCH, R
    ROHL, L
    EUROPEAN UROLOGY, 1978, 4 (05) : 379 - 381
  • [30] CLOSURE OF THE PERICARDIUM USING EXPANDED POLYTETRAFLUOROETHYLENE GORE-TEX SURGICAL MEMBRANE - CLINICAL-EXPERIENCE
    MINALE, C
    HOLLWEG, G
    NIKOL, S
    MITTERMAYER, C
    MESSMER, BJ
    THORACIC AND CARDIOVASCULAR SURGEON, 1987, 35 (05): : 312 - 315