Safety of magnetic resonance imaging in patients with permanent pacemakers: a collaborative clinical approach

被引:32
|
作者
Boilson, Barry Anthony [1 ]
Wokhlu, Anita [1 ]
Acker, Nancy G. [1 ]
Felmlee, Joel P. [2 ,3 ]
Watson, Robert E., Jr. [2 ]
Julsrud, Paul R. [2 ,4 ]
Friedman, Paul A. [1 ]
Cha, Yong-Mei [1 ]
Rea, Robert F. [1 ]
Hayes, David L. [1 ]
Shen, Win-Kuang [1 ]
机构
[1] Mayo Clin, Div Cardiovasc Dis, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[3] Mayo Clin, Dept Physiol & Biomed Engn, Rochester, MN 55905 USA
[4] Mayo Clin, Dept Hlth Sci Res, Rochester, MN 55905 USA
关键词
Arrhythmias; Device interactions; Magnetic resonance imaging; Permanent pacemakers; Power-on resetting; IMPLANTABLE-CARDIOVERTER-DEFIBRILLATORS; CARDIAC-PACEMAKERS; INDUSTRY VIEWPOINT; 1.5; TESLA; IN-VITRO; MRI-SAFE; ICDS; ISSUES; PERFORMANCE; 1.5-TESLA;
D O I
10.1007/s10840-011-9615-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study aimed to characterize the interactions of pacemakers with magnetic resonance imaging (MRI) and to identify device characteristics that could predict adverse interactions. The safety of MRI in patients with indwelling pacemaker systems remains uncertain. Previous studies demonstrated safety in most patients, but unpredictable, potentially concerning changes in pacemaker behavior have occurred. We prospectively studied patients with pacemaker devices in situ who were not pacemaker dependent and in whom MRI was essential for adequate diagnosis and treatment. All patients were monitored by electrocardiography and pulse oximetry during scanning; devices were interrogated and cardiac enzymes were measured before and after scanning. Of 32 patients studied (46 MRI examinations), 28 patients had a dual-chamber system and one had a biventricular device. Regions scanned were the head and spine. Devices were reprogrammed to asynchronous pacing or sense-only mode in all except six patients before MRI. During six scanning episodes (five patients), "power-on" resetting of the device was noted. Magnet-mode pacing was noted during four episodes (three patients). Occasional premature ventricular contractions were noted in one patient. No significant changes in battery voltage, sensed P wave and R wave, pacing thresholds, lead impedance, or cardiac enzymes were noted immediately after MRI or at 1-month follow-up. Overall, no significant changes were seen in pacemaker device function, and no adverse clinical events were observed. A minority of patients with older devices had unpredictable changes in device behavior, which stresses the need for close monitoring during and careful device interrogation after scanning.
引用
收藏
页码:59 / 67
页数:9
相关论文
共 50 条
  • [21] Hemodynamic response and safety of vasodilator stress cardiovascular magnetic resonance in patients with permanent pacemakers or implantable cardioverter-defibrillators
    Miller, Lauren
    Airapetov, Sergei
    Pillai, Ajay
    Kalahasty, Gautham
    Ellenbogen, Kenneth A.
    Hundley, W. Gregory
    Trankle, Cory R.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (10) : 2127 - 2135
  • [22] Magnetic Resonance Imaging in Patients With Implantable Cardioverter-Defibrillators and Pacemakers
    Roguin, Ariel
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (06) : 556 - 557
  • [23] Can patients with implanted pacemakers/ICD undergo magnetic resonance imaging?
    Sermasi, S.
    Marconi, M.
    Mezzetti, M.
    Piovaccari, G.
    CARDIAC ARRHYTHMIAS 2005, 2005, : 627 - 630
  • [24] Can patients with implantable pacemakers safely undergo magnetic resonance imaging?
    Gimbel, JR
    Kanal, E
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (07) : 1325 - 1327
  • [25] Magnetic resonance imaging of the brain can be safely performed in patients with pacemakers
    Bailey, SM
    Juratli, NM
    Ruggieri, PM
    Sparker, JK
    Tchou, PJ
    Wilkoff, BL
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 113A - 113A
  • [26] EFFECT OF 1.5 TESLA NUCLEAR-MAGNETIC-RESONANCE IMAGING SCANNER ON IMPLANTED PERMANENT PACEMAKERS
    HAYES, DL
    HOLMES, DR
    GRAY, JE
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (04) : 782 - 786
  • [27] Implantable pulse generators (pacemakers) and electrodes: Safety in the magnetic resonance imaging scanner environment
    Bhachu, DS
    Kanal, E
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 12 (01) : 201 - 204
  • [28] Feasibility of adenosine stress cardiovascular magnetic resonance perfusion imaging in patients with MR-conditional transvenous permanent pacemakers and defibrillators
    Pavon, Anna Giulia
    Porretta, Alessandra Pia
    Arangalage, Dimitri
    Domenichini, Giulia
    Rutz, Tobias
    Hugelshofer, Sarah
    Pruvot, Etienne
    Monney, Pierre
    Pascale, Patrizio
    Schwitter, Juerg
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2022, 24 (01)
  • [29] Feasibility of adenosine stress cardiovascular magnetic resonance perfusion imaging in patients with MR-conditional transvenous permanent pacemakers and defibrillators
    Anna Giulia Pavon
    Alessandra Pia Porretta
    Dimitri Arangalage
    Giulia Domenichini
    Tobias Rutz
    Sarah Hugelshofer
    Etienne Pruvot
    Pierre Monney
    Patrizio Pascale
    Juerg Schwitter
    Journal of Cardiovascular Magnetic Resonance, 24
  • [30] Outcomes after magnetic resonance imaging in patients with pacemakers and defibrillators and abandoned leads
    Morris, Michael F.
    Verma, Divya Ratan
    Sheikh, Hasaam
    Su, Wilber
    Pershad, Ashish
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2018, 19 (06) : 685 - 688