Safety of magnetic resonance imaging in patients with permanent pacemakers: a collaborative clinical approach

被引:32
|
作者
Boilson, Barry Anthony [1 ]
Wokhlu, Anita [1 ]
Acker, Nancy G. [1 ]
Felmlee, Joel P. [2 ,3 ]
Watson, Robert E., Jr. [2 ]
Julsrud, Paul R. [2 ,4 ]
Friedman, Paul A. [1 ]
Cha, Yong-Mei [1 ]
Rea, Robert F. [1 ]
Hayes, David L. [1 ]
Shen, Win-Kuang [1 ]
机构
[1] Mayo Clin, Div Cardiovasc Dis, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[3] Mayo Clin, Dept Physiol & Biomed Engn, Rochester, MN 55905 USA
[4] Mayo Clin, Dept Hlth Sci Res, Rochester, MN 55905 USA
关键词
Arrhythmias; Device interactions; Magnetic resonance imaging; Permanent pacemakers; Power-on resetting; IMPLANTABLE-CARDIOVERTER-DEFIBRILLATORS; CARDIAC-PACEMAKERS; INDUSTRY VIEWPOINT; 1.5; TESLA; IN-VITRO; MRI-SAFE; ICDS; ISSUES; PERFORMANCE; 1.5-TESLA;
D O I
10.1007/s10840-011-9615-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study aimed to characterize the interactions of pacemakers with magnetic resonance imaging (MRI) and to identify device characteristics that could predict adverse interactions. The safety of MRI in patients with indwelling pacemaker systems remains uncertain. Previous studies demonstrated safety in most patients, but unpredictable, potentially concerning changes in pacemaker behavior have occurred. We prospectively studied patients with pacemaker devices in situ who were not pacemaker dependent and in whom MRI was essential for adequate diagnosis and treatment. All patients were monitored by electrocardiography and pulse oximetry during scanning; devices were interrogated and cardiac enzymes were measured before and after scanning. Of 32 patients studied (46 MRI examinations), 28 patients had a dual-chamber system and one had a biventricular device. Regions scanned were the head and spine. Devices were reprogrammed to asynchronous pacing or sense-only mode in all except six patients before MRI. During six scanning episodes (five patients), "power-on" resetting of the device was noted. Magnet-mode pacing was noted during four episodes (three patients). Occasional premature ventricular contractions were noted in one patient. No significant changes in battery voltage, sensed P wave and R wave, pacing thresholds, lead impedance, or cardiac enzymes were noted immediately after MRI or at 1-month follow-up. Overall, no significant changes were seen in pacemaker device function, and no adverse clinical events were observed. A minority of patients with older devices had unpredictable changes in device behavior, which stresses the need for close monitoring during and careful device interrogation after scanning.
引用
收藏
页码:59 / 67
页数:9
相关论文
共 50 条
  • [1] Safety of magnetic resonance imaging in patients with permanent pacemakers: a collaborative clinical approach
    Barry Anthony Boilson
    Anita Wokhlu
    Nancy G. Acker
    Joel P. Felmlee
    Robert E. Watson
    Paul R. Julsrud
    Paul A. Friedman
    Yong-Mei Cha
    Robert F. Rea
    David L. Hayes
    Win-Kuang Shen
    Journal of Interventional Cardiac Electrophysiology, 2012, 33 : 59 - 67
  • [2] Magnetic resonance imaging for patients with permanent pacemakers: Initial clinical experience
    Goldsher, D
    Amikam, S
    Boulos, M
    Suleiman, M
    Shreiber, R
    Eran, A
    Goldshmid, Y
    Mazbar, R
    Roguin, A
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2006, 8 (02): : 91 - 94
  • [3] Clinical utility and safety of a protocol for magnetic resonance Imaging of patients with permanent pacemakers and implantable cardioverter defibrillators at 1.5 tesia
    Nazarian, S
    Roguin, A
    Zviman, MM
    Lardo, AC
    Dickfeld, TL
    Berger, RD
    Bluemke, DA
    Halperin, HR
    CIRCULATION, 2005, 112 (17) : U575 - U575
  • [4] Safety of thoracic magnetic resonance imaging for patients with pacemakers and defibrillators
    Padmanabhan, Deepak
    Kella, Danesh K.
    Deshmukh, Abhishek J.
    Mulpuru, Siva K.
    Mehta, Ramila A.
    Dalzell, Connie M.
    Olson, Nora E.
    Felmlee, Joel P.
    Jondal, Mary L.
    Asirvatham, Samuel J.
    Watson, Robert E., Jr.
    Cha, Yong-Mei
    Friedman, Paul A.
    HEART RHYTHM, 2019, 16 (11) : 1645 - 1651
  • [5] SAFETY OF THORACIC MAGNETIC RESONANCE IMAGING IN PATIENTS WITH PACEMAKERS AND DEFIBRILLATORS
    Padmanabhan, Deepak
    Kella, Danesh
    Naksuk, Niyada
    Deshmukh, Abhishek
    Mulpuru, Siva
    Kapa, Suraj
    Mehta, Ramila
    Dalzell, Connie
    Olson, Nora
    Felmlee, Joel
    Jondal, Mary Lou
    Asirvatham, Samuel
    Watson, Robert
    Cha, Yong-Mei
    Friedman, Paul
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1599 - 1599
  • [6] Safe performance of magnetic resonance imaging on five patients with permanent cardiac pacemakers
    Gimbel, JR
    Johnson, D
    Levine, PA
    Wilkoff, BL
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (06): : 913 - 919
  • [7] Clinical utility and safety of a protocol for noncardiac and cardiac magnetic resonance imaging of patients with permanent pacemakers and implantable- cardioverter defibrillators at 1.5 tesla
    Nazarian, Saman
    Roguin, Ariel
    Zviman, Menekhem M.
    Lardo, Albert C.
    Dickfeld, Timm L.
    Calkins, Hugh
    Weiss, Robert G.
    Berger, Ronald D.
    Bluemke, David A.
    Halperin, Henry R.
    CIRCULATION, 2006, 114 (12) : 1277 - 1284
  • [8] Clinical Utility of Magnetic Resonance Imaging of Patients with Permanent Pacemakers and Implantable-Cardioverter Defibrillators at 1.5 Tesla
    Nazarian, Semen
    Hansford, Rozann
    Roguin, Ariel
    Zviman, Menekhem M.
    Lardo, Albert C.
    Calkins, Hugh
    Berger, Ronald D.
    Bluemke, David A.
    Halperin, Henry R.
    CIRCULATION, 2008, 118 (18) : S777 - S778
  • [9] Evaluation of a safety protocol for clinically indicated magnetic resonance imaging of patients with permanent pacemakers and implantable defibrillators at 1.5 tesla
    Nazarjan, S
    Roguin, A
    Zviman, MM
    Lardo, AC
    Dickfeld, TL
    Berger, RD
    Bluemke, DA
    Halperin, HR
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 14A - 14A
  • [10] Safety of magnetic resonance imaging in patients with legacy pacemakers and defibrillators and abandoned leads
    Padmanabhan, Deepak
    Kella, Danesh K.
    Mehta, Ramila
    Kapa, Suraj
    Deshmukh, Abhishek
    Mulpuru, Siva
    Jaffe, Allan S.
    Felmlee, Joel P.
    Jondal, Mary L.
    Dalzell, Connie M.
    Asirvatham, Samuel J.
    Cha, Yong-Mei
    Watson, Robert E., Jr.
    Friedman, Paul A.
    HEART RHYTHM, 2018, 15 (02) : 228 - 233