共 50 条
Cataract Risk in a Cohort of US Radiologic Technologists Performing Nuclear Medicine Procedures
被引:24
|作者:
Bernier, Marie-Odile
[1
,2
]
Journy, Neige
[1
]
Villoing, Daphnee
[1
]
Doody, Michele M.
[1
]
Alexander, Bruce H.
[3
]
Linet, Martha S.
[1
]
Kitahara, Cari M.
[1
]
机构:
[1] NCI, Radiat Epidemiol Branch, Div Canc Epidemiol & Genet, 9609 Med Ctr Dr, Rockville, MD 20850 USA
[2] Inst Radioprotect & Surete Nucl, Fontenay Aux Roses, France
[3] Univ Minnesota, Sch Publ Hlth, Div Environm Hlth Sci, Minneapolis, MN USA
来源:
基金:
美国国家卫生研究院;
关键词:
OCCUPATIONAL DOSE DISTRIBUTION;
IONIZING-RADIATION;
CANCER-RISKS;
EYE DISEASE;
LENS;
EXPOSURE;
OPACITIES;
PERSONNEL;
SURVIVORS;
STAFF;
D O I:
10.1148/radiol.2017170683
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Purpose: To estimate the risk of cataract in a cohort of nuclear medicine (NM) radiologic technologists on the basis of their work histories and radiation protection practices. Materials and Methods: In the years 2003-2005 and 2012-2013, 42 545 radiologic technologists from a U.S. prospective study completed questionnaires in which they provided information regarding their work histories and cataract histories. Cox proportional hazards models, stratified according to birth-year cohort (born before 1940 or born in 1940 or later) and adjusted for age, sex, and race, were used to estimate hazard ratios (HRs) for the risk of cataract in radiologic technologists according to NM work history practices according to decade. Results: During the follow-up period (mean follow-up, 71/2 years), 7137 incident cataracts were reported. A significantly increased risk of cataract (HR, 1.08; 95% confidence interval [CI]: 1.03, 1.14) was observed among workers who performed an NM procedure at least once-as opposed to never. Risks of cataract were increased in the group who had performed a diagnostic (HR, 1.07; 95% CI: 1.01, 1.12) or therapeutic (HR, 1.10; 95% CI: 1.04, 1.17) NM procedure. Risks were higher for those who had first performed diagnostic NM procedures in the 1980s to early 2000s (HR, 1.30; 95% CI: 1.08, 1.58) and those who had performed therapeutic NM procedures in the 1970s (HR, 1.11; 95% CI: 1.01, 1.23) and in the 1980s to early 2000s (HR, 1.14; 95% CI: 1.02, 1.29). With the exception of a significantly increased risk associated with performing therapeutic NM procedures without shielding the radiation source in the 1980s (HR, 1.32; 95% CI: 1.04, 1.67), analyses revealed no association between cataract risk and specific radiation protection technique used. Conclusion: An increased risk of cataract was observed among U.S. radiologic technologists who had performed an NM procedure at least once. This association should be examined in future studies incorporating estimated lens doses.
引用
收藏
页码:592 / 601
页数:10
相关论文