Reference Values of Right Atrial Longitudinal Strain Imaging by Two-Dimensional Speckle Tracking

被引:83
|
作者
Padeletti, Margherita [1 ]
Cameli, Matteo [1 ]
Lisi, Matteo [1 ]
Malandrino, Angela [1 ]
Zaca, Valerio [1 ]
Mondillo, Sergio [1 ]
机构
[1] Univ Siena, Dipartimento Cardiol, I-53100 Siena, Italy
关键词
echocardiography; speckle tracking; right atrium; AMERICAN-SOCIETY; EUROPEAN-ASSOCIATION; STANDARDS COMMITTEE; ECHOCARDIOGRAPHY; RECOMMENDATIONS; QUANTIFICATION; DEFORMATION; GUIDELINES; BRANCH; HEART;
D O I
10.1111/j.1540-8175.2011.01564.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The role of speckle tracking in the assessment of right atrial (RA) deformation dynamics has not been established yet. The reference ranges of RA longitudinal strain indices were measured by speckle tracking in a population of normal subjects. Methods: In 84 healthy individuals, peak atrial longitudinal strain (PALS), peak atrial contraction strain (PACS), and time to peak longitudinal strain (TPLS) were measured using a six-segment model for the RA. Strain rate (SR) was also measured starting from the QRS-wave onset, peak positive (x-wave), first peak negative (y-wave), and second negative peak (z-wave). The time from the QRS onset was measured to each wave peak. Results: Adequate tracking quality was achieved in 64% of segments analyzed. Inter- and intraobserver variability coefficients of measurements ranged between 6% and 11%. Global PALS was 49 +/- 13%, global TPLS was 363 +/- 59 msec, x-wave was 2.12 +/- 0.58 sec(-1), y-wave was -1.91 +/- 0.63 sec(-1), and z-wave was -2.18 +/- 0.78 sec(-1). Conclusion: Speckle tracking is a feasible technique for the assessment of longitudinal myocardial RA deformation. Reference ranges of strain indices were reported. (Echocardiography 2012;29:147-152)
引用
收藏
页码:147 / 152
页数:6
相关论文
共 50 条
  • [41] Evaluation of right atrial function by two-dimensional speckle-tracking echocardiography in patients with right ventricular myocardial infarction
    Nourian, Saeed
    Hosseinsabet, Ali
    Jalali, Arash
    Mohseni-Badalabadi, Reza
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (01): : 47 - 56
  • [42] A two-dimensional CVIB imaging system with a speckle tracking algorithm
    Bai, Jing
    Liu, Ke
    Jiang, Yong
    Ying, Kui
    Zhang, Pengfei
    Shao, Jinhua
    ULTRASONICS, 2008, 48 (05) : 394 - 402
  • [43] Right Atrial Speckle Tracking Strain Echocardiography in HeartFailure
    Khan, Saleen
    Alenezi, Fawaz
    Bloomfield, Gerald
    JOURNAL OF CARDIAC FAILURE, 2018, 24 (08) : S38 - S38
  • [44] Left Atrial Strain Measured by Two-Dimensional Speckle Tracking Represents a New Tool to Evaluate Left Atrial Function
    Saraiva, Roberto M.
    Demirkol, Sayit
    Buakhamsri, Adisai
    Greenberg, Neil
    Popovic, Zoran B.
    Thomas, James D.
    Klein, Allan L.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (02) : 172 - 180
  • [45] Global Longitudinal Strain in Relation to the Severity of Aortic Stenosis: A Two-Dimensional Speckle-Tracking Study
    Miyazaki, Sakiko
    Daimon, Masao
    Miyazaki, Tadashi
    Onishi, Yuko
    Koiso, Yoko
    Nishizaki, Yuji
    Ichikawa, Ryoko
    Chiang, Shuo-Ju
    Makinae, Haruka
    Suzuki, Hiromasa
    Daida, Hiroyuki
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2011, 28 (07): : 703 - 708
  • [46] Prognostic Value of Right Ventricular Two-Dimensional and Three-Dimensional Speckle-Tracking Strain in Pulmonary Arterial Hypertension: Superiority of Longitudinal Strain over Circumferential and Radial Strain
    Li, Yuman
    Wang, Tao
    Haines, Philip
    Li, Mengmei
    Wu, Wenqian
    Liu, Manwei
    Chen, Yihan
    Jin, Qiaofeng
    Xie, Yuji
    Wang, Jing
    Yang, Yali
    Zhang, Li
    Lv, Qing
    Xie, Mingxing
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2020, 33 (08) : 985 - +
  • [47] Right Ventricular Myocardial Strain Evaluated by Two-Dimensional Echocardiographic Speckle Tracking is Strongly Associated with Right Ventricular Contractile Function by Magnetic Resonance Imaging
    Kato, Shingo
    Kusakawa, Yuka
    Ishii, Nao
    Muto, Kazuhiro
    Nakachi, Tatsuya
    Okusu, Yasuo
    Nakagawa, Tsuyoshi
    Fukui, Kazuki
    Uchino, Kazuaki
    Kimura, Kazuo
    Umemura, Satoshi
    CIRCULATION, 2011, 124 (21)
  • [48] Two-dimensional speckle tracking strain echocardiography in heart transplant patients
    Syeda, B.
    Hoefer, P.
    Pichler, P.
    Vertesich, M.
    Roedler, S.
    Mahr, S.
    Graf, S.
    Bergler-Klein, J.
    Glogar, D.
    Binder, T.
    EUROPEAN HEART JOURNAL, 2009, 30 : 345 - 345
  • [49] Reduced longitudinal and radial strain of the left ventricle in patients with hypertrophic cardiomyopathy (HCM): a study using two-dimensional speckle tracking imaging
    Abozguia, K.
    Shivu, G. Nallur
    Ahmed, I.
    Phan, T. T.
    Maher, A. R.
    Mckenna, W. J.
    Elliott, P. M.
    Frenneaux, M. P.
    EUROPEAN HEART JOURNAL, 2008, 29 : 55 - 55
  • [50] Evaluation of the right parasternal four-chamber view for the assessment of left ventricular longitudinal strain and strain rate by two-dimensional speckle tracking echocardiography in dogs
    Santarelli, Giorgia
    Talavera Lopez, Jesus
    Fernandez del Palacio, Josefa
    RESEARCH IN VETERINARY SCIENCE, 2018, 120 : 78 - 85