Diagnostics of an inductively coupled plasma in oxygen

被引:30
|
作者
Tadokoro, M [1 ]
Itoh, A
Nakano, N
Petrovic, ZL
Makabe, T
机构
[1] Keio Univ, Dept Elect Engn, Yokohama, Kanagawa 223, Japan
[2] Shibaura Engn Works Co Ltd, Zama 228, Japan
[3] Univ Belgrade, Inst Phys, YU-11001 Belgrade, Yugoslavia
关键词
CT image; inductively coupled plasma; plasma ashing; plasma diagnostics; radon inversion;
D O I
10.1109/27.747892
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
Spatial time-integrated and space-time resolved profiles of excited atoms of oxygen were measured by optical emission spectroscopy for inductively coupled plasma (TCP) in oxygen, Discharge was sustained by a single turn coil supplied by 13.56 MHz RF generator delivering 100 and 200 W of power. The spatial emission profiles give the anatomy of the discharge required in order to understand the basic kinetics of ICP, Two types of nonuniformities are observed, azimuthal anisotropy and radial nonuniformity, both Caused by spatially dependent energy supply to the electrons. Our experimental results show that oxygen is much more affected by azimuthal anisotropy and radial nonuniformity than argon, It is due to a different role of metastable atoms in kinetics of excitation, whereby stepwise excitation in oxygen is less probable than in argon, Optical emission data are supplemented by Langmuir probe measurements of electron densities and plasma potentials, Electrons gain energy from the time varying fields close to the coil, and the energy is not redistributed along the radius before it is dissipated in excitation, thus the observations are not consistent with the nonlocal theory predictions for the range of pressures, geometry, and power covered in this paper.
引用
收藏
页码:1724 / 1732
页数:9
相关论文
共 50 条
  • [1] DIAGNOSTICS IN AN AIR INDUCTIVELY COUPLED PLASMA
    KOVACIC, N
    MEYER, GA
    LIU, KL
    BARNES, RM
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1985, 40 (07) : 943 - 957
  • [2] Tools for Diagnostics of Inductively Coupled Plasma Spectrometers
    Svejcarova, Daniela
    Fisera, Miroslav
    [J]. CHEMICKE LISTY, 2009, 103 (09): : 733 - 739
  • [3] Instabilities in an inductively coupled oxygen plasma
    Corr, CS
    Steen, PG
    Graham, WG
    [J]. PLASMA SOURCES SCIENCE & TECHNOLOGY, 2003, 12 (02): : 265 - 272
  • [4] A LOW-POWER OXYGEN INDUCTIVELY COUPLED PLASMA FOR SPECTROCHEMICAL ANALYSIS .2. PLASMA DIAGNOSTICS
    YANG, P
    BARNES, RM
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1989, 44 (11) : 1093 - 1107
  • [5] Spectral diagnostics of inductively coupled RF discharge plasma
    I. Sh. Abdullin
    A. N. Bykanov
    I. G. Gafarov
    O. E. Ibragimov
    R. F. Sharafeev
    [J]. High Energy Chemistry, 2012, 46 : 271 - 275
  • [6] Spectral diagnostics of inductively coupled RF discharge plasma
    Abdullin, I. Sh
    Bykanov, A. N.
    Gafarov, I. G.
    Ibragimov, O. E.
    Sharafeev, R. F.
    [J]. HIGH ENERGY CHEMISTRY, 2012, 46 (04) : 271 - 275
  • [7] Plasma diagnostics in a double inductively coupled source (DICP) for plasma sterilisation
    Messerer, P
    Boenigk, B
    Keil, G
    Scheubert, P
    Awakowicz, P
    [J]. SURFACE & COATINGS TECHNOLOGY, 2003, 174 : 570 - 573
  • [8] Dynamics of a pulsed inductively coupled oxygen plasma
    Zaka-ul-Islam, Mujahid
    [J]. PHYSICS OF PLASMAS, 2016, 23 (11)
  • [9] Diagnostics of an inductively coupled CF4/Ar plasma
    Hioki, K
    Hirata, H
    Matsumura, S
    Petrovic, ZL
    Makabe, T
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2000, 18 (03): : 864 - 872
  • [10] Langmuir probe diagnostics of a microfabricated inductively coupled plasma on a chip
    Minayeva, OB
    Hopwood, J
    [J]. JOURNAL OF APPLIED PHYSICS, 2003, 94 (05) : 2821 - 2828