The impact of different dental restorations on detection of proximal caries by cone beam computed tomography

被引:8
|
作者
Abu El-Ela, Walaa Hussein [1 ]
Farid, Mary Medhat [1 ]
Abou El-Fotouh, Mona [1 ]
机构
[1] Ain Shams Univ, Fac Dent, Dept Oral & Maxillofacial Radiol, Monazamet El Wehda El Afriqeya St, Cairo, Egypt
关键词
Dental caries; Artifacts; Dental restoration; Crowns; Cone beam CT; DIAGNOSTIC-ACCURACY; CT; RADIOGRAPHS; RADIOPACITY; MODALITIES; ARTIFACTS; OCCLUSAL; PHOSPHOR; SCANS; FILM;
D O I
10.1007/s00784-021-04207-w
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives To evaluate the effects of different types of restorations on observer ability to detect proximal caries in CBCT images. Materials and methods Forty human premolars and molars with artificial proximal caries were placed proximal and distal to 5 molars having different restorations (amalgam, composite, resin-modified glass ionomer cement (RMGIC) fillings, zirconia, and lithium disilicate crowns) and a non-restored molar. CBCT scans were obtained using i-CAT((R) )Next Generation. Images were rated twice by 2 observers. The exact depth of artificial caries was histologically established. Sensitivity, specificity, and area under the receiver operating characteristic curve (Az) values were calculated. Results Caries detection in teeth surfaces mesial and distal to amalgam showed compromised specificity and accuracy. Moreover, caries detection in teeth surfaces mesial to zirconia crown showed low sensitivity, specificity, and accuracy. Capability of CBCT in detection of proximal caries in teeth adjacent to composite, RMGIC, and lithium disilicate was comparable to those adjacent to non-restored molar. Conclusions CBCT scans performed for tasks other than caries detection should be assessed for proximal caries in absence of any restorations as well as in presence of composite, RMGIC fillings, and lithium disilicate crowns. However, CBCT should not be used for proximal caries detection in teeth adjacent to amalgam and teeth surfaces mesial to zirconia crowns. Clinical significance It is important to investigate the influence of artifacts produced by various restorations on CBCT-based caries detection to optimize CBCT benefits, caries diagnosis and avoid unnecessary treatment of sound surfaces.
引用
收藏
页码:2413 / 2420
页数:8
相关论文
共 50 条
  • [1] The impact of different dental restorations on detection of proximal caries by cone beam computed tomography
    Walaa Hussein Abu El-Ela
    Mary Medhat Farid
    Mona Abou El-Fotouh
    Clinical Oral Investigations, 2022, 26 : 2413 - 2420
  • [2] In vitro assessment of cone beam local computed tomography for proximal caries detection
    Kalathingal, Sajitha M.
    Mol, Andre
    Tyndall, Donald A.
    Caplan, Daniel J.
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2007, 104 (05): : 699 - 704
  • [3] Current status of dental caries diagnosis using cone beam computed tomography
    Park, Young-Seok
    Ahn, Jin-Soo
    Kwon, Ho-Beom
    Lee, Seung-Pyo
    IMAGING SCIENCE IN DENTISTRY, 2011, 41 (02) : 43 - 51
  • [4] Detection accuracy of in vitro approximal caries by cone beam computed tomography images
    Qu, Xingmin
    Li, Gang
    Zhang, Zuyan
    Ma, Xuchen
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 79 (02) : E24 - E27
  • [5] Comparison of photothermal radiometry and modulated luminescence, intraoral radiography, and cone beam computed tomography for detection of natural caries under restorations
    Dayo, Adeyinka F.
    Amaechi, Bennett T.
    Noujeim, Marcel
    Deahl, S. Thomas
    Gakunga, Peter
    Katkar, Rujuta
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2020, 129 (05): : 539 - 548
  • [6] Effect of Amalgam Restorations and Operation Parameters on Diagnostic Accuracy of Caries Detection Using Cone Beam Computed Tomography: An In Vitro Study
    Mehanny, Mohamed
    AlMohareb, Rahaf A.
    Noujeim, Marcel
    SCANNING, 2021, 2021
  • [7] In Vitro Detection of Dental Root Fractures with Cone Beam Computed Tomography (CBCT)
    Fisekcioglu, Erdogan
    Dolekoglu, Semanur
    Ilguy, Mehmet
    Ersan, Nilufer
    Ilguy, Dilhan
    IRANIAN JOURNAL OF RADIOLOGY, 2014, 11 (01)
  • [8] Detection of dental root fractures by using cone-beam computed tomography
    Wang, P.
    Yan, X. B.
    Lui, D. G.
    Zhang, W. L.
    Zhang, Y.
    Ma, X. C.
    DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (05) : 290 - 298
  • [9] Detection accuracy of proximal caries by phosphor plate and cone-beam computerized tomography images scanned with different resolutions
    Cheng, Jun-Ge
    Zhang, Zhi-Ling
    Wang, Xiao-Yan
    Zhang, Zu-Yan
    Ma, Xu-Chen
    Li, Gang
    CLINICAL ORAL INVESTIGATIONS, 2012, 16 (04) : 1015 - 1021
  • [10] Detection accuracy of proximal caries by phosphor plate and cone-beam computerized tomography images scanned with different resolutions
    Jun-Ge Cheng
    Zhi-Ling Zhang
    Xiao-Yan Wang
    Zu-Yan Zhang
    Xu-Chen Ma
    Gang Li
    Clinical Oral Investigations, 2012, 16 : 1015 - 1021