The effects of maternal position during induction of combined spinal-epidural anesthesia for cesarean delivery

被引:47
|
作者
Yun, EM
Marx, GF
Santos, AC
机构
[1] Montefiore Med Ctr, Albert Einstein Coll Med, Dept Anesthesiol, Bronx, NY 10467 USA
[2] Montefiore Med Ctr, Albert Einstein Coll Med, Dept Gynecol & Obstet, Bronx, NY 10467 USA
来源
ANESTHESIA AND ANALGESIA | 1998年 / 87卷 / 03期
关键词
D O I
10.1097/00000539-199809000-00023
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Combined spinal-epidural anesthesia (CSE) is a popular technique for cesarean delivery. Regional blocks in obstetrics are often performed with the parturient in the sitting position because the midline may be recognized more easily than in the lateral decubitus position. When conventional spinal anesthesia is performed in the sitting position, the patient is placed supine immediately after drug injection. In contrast, when CSE is performed with the woman sitting, there is a delay in assuming the supine position because of epidural catheter placement, which may affect the incidence of hypotension. Healthy women, at term of pregnancy, about to undergo an elective cesarean section under CSE, were randomly assigned to the sitting or lateral recumbent position for initiation of the block. All parturients were given 1000 mt of lactated Ringer's solution in the 15 min preceding induction and an additional 300-500 mt while the actual block was being performed. On completion of the CSE, they were turned to the supine position with left uterine displacement. A second anesthesiologist, blinded to the woman's position during CSE, evaluated the sensory level of anesthesia, maternal heart rate, blood pressure, oxygen saturation, need for ephedrine, and occurrence of nausea and vomiting. Results are expressed as mean +/- so. Twelve women were studied in the sitting group and 10 were studied in the lateral recumbent group. The severity and duration of hypotension were greater in those parturients who had CSE induced in the sitting (47% +/- 7% and 6 +/- 3 min, respectively) compared with the lateral recumbent position (32% +/- 14% and 3 +/- 2 min, respectively). Women in the sitting group also required twice as much ephedrine(38 +/- 18 mg) to correct hypotension compared with the other group (17 +/- 12 mg). In conclusion, the severity and duration of hypotension were greater when CSE was induced in the sitting compared with Be lateral decubitus position. Implications: We studied the induction of combined spinal-epidural anesthesia (CSE) in the sitting versus lateral recumbent positions in healthy women undergoing a scheduled cesarean delivery. The severity and duration of hypotension were greater when CSE was induced in the sitting position. Thus, the position used for induction of CSE should be among the factors considered when there is greater maternal or fetal risk from hypotension.
引用
收藏
页码:614 / 618
页数:5
相关论文
共 50 条
  • [41] NEEDLE COMPATIBILITY AND COMBINED SPINAL-EPIDURAL ANESTHESIA
    UNCLES, DR
    WESTBROOK, JL
    ANAESTHESIA, 1994, 49 (07) : 646 - 646
  • [42] Effects of a head elevated ramped position during elective caesarean delivery after combined spinal-epidural anaesthesia
    Cheesman, K.
    Massey, S.
    Preston, R.
    Albert, A.
    Douglas, J.
    INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2014, 23 (02) : 106 - 112
  • [43] The evolution of combined spinal-epidural anesthesia needles
    Eldor, J
    REGIONAL ANESTHESIA, 1997, 22 (03) : 294 - 296
  • [44] A NEW COMBINED SPINAL-EPIDURAL ANESTHESIA NEEDLE
    ELDOR, J
    GUEDJ, P
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 1990, 9 (06): : 571 - 572
  • [46] Combined spinal-epidural anesthesia for renal transplantation
    Bhosale, G.
    Shah, V.
    TRANSPLANTATION PROCEEDINGS, 2008, 40 (04) : 1122 - 1124
  • [47] Combined spinal-epidural anesthesia with non-invasive ventilation during cesarean delivery of a woman with a recent diagnosis of amyotrophic lateral sclerosis
    Kock-Cordeiro, D. B. M.
    Brusse, E.
    van den Biggelaar, R. J. M.
    Eggink, A. J.
    van der Marel, C. D.
    INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2018, 36 : 108 - 110
  • [48] Maternal Hypotension During Spinal Anesthesia for Cesarean Delivery
    Mavridou I.
    Stewart A.
    Fernando R.
    Current Anesthesiology Reports, 2013, 3 (4) : 282 - 291
  • [49] Cauda equina syndrome following combined spinal-epidural anesthesia with levobupivacaine for cesarean section
    Marinho, S.
    Frias, P.
    Oliveira, I
    Bento, C. Melo
    Rodrigues, F.
    Paiva, A.
    REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION, 2021, 68 (08): : 484 - 486
  • [50] Combined spinal-epidural anesthesia for cesarean section; Needle-through-needle approach
    Tsutsui T.
    Nakamura K.
    Muranaka K.
    Journal of Anesthesia, 1998, 12 (1) : 13 - 16