Laboratory and field performance of a laser particle counter for measuring aeolian sand transport

被引:50
|
作者
Hugenholtz, Chris H. [1 ]
Barchyn, Thomas E. [1 ]
机构
[1] Univ Lethbridge, Dept Geog, Lethbridge, AB T1K 3M4, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
BLOWING SNOW; ACOUSTIC SENSORS; FLUX; SNOWDRIFT; VELOCITY; DESIGN;
D O I
10.1029/2010JF001822
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
This paper reports the results of laboratory and field tests that evaluate the performance of a new laser particle counter for measuring aeolian sand transport. The Wenglor (R) model YH03PCT8 ("Wenglor") consists of a laser (655 nm), photo sensor, and switching circuit. When a particle passes through the 0.6 mm diameter, 30 mm long laser beam, the sensor outputs a digital signal. Laboratory tests with medium sand and a vertical gravity flume show that the Wenglor count rate scales approximately linearly with mass flux up to the saturation point of the sensor, after which the count rate decreases despite increasing mass flux. Saturation depends on the diameter and concentration of particles in the airstream and may occur during extreme events in the field. Below saturation sensor performance is relatively consistent; the mean difference between average count rate response was between 50 and 100 counts. Field tests provide a complimentary frame of reference for evaluating the performance of the Wenglor under varying environmental conditions and to gauge its performance with respect to a collocated piezoelectric impact sensor (Sensit H11-B). During 136.5 h of deployment on an active sand dune the relative proportion of time sand transport recorded by two Wenglors was 0.09% and 0.79%, compared to 4.68% by the Sensit H11-B. The weak performance of the Wenglors is attributed to persistent lens contamination from adhesion of sand grains on the sensors after rainfall. However, during dry and windy conditions the Wenglor performance improved substantially; sensors measured a concentration of sand particles in the airstream more than seven times greater than that measured by the Sensit. Between the two Wenglors, the mean absolute count rate difference was 6.16 counts per second, with a standard deviation of 8.53 counts per second. For short-term measurement campaigns in dry conditions, therefore, the Wenglor is relatively consistent and can outperform the Sensit in detecting particles in the airstream. The Sensit, however, is more reliable in detecting particle transport during longer unattended deployments. Two additional field tests show that the sensor is well-suited to the measurement of snow drifting but could be ineffective in dusty settings because of lens contamination. Overall, the main advantages of the Wenglor include (1) insensitivity to particle momentum; (2) low measurement variability; (3) low cost ($210 USD); and perhaps most important of all, (4) a consistent design that will improve comparison of results between investigations. At present, no other particle detector used in aeolian research can claim all these characteristics.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] A Random Pairing Collision Model (RPCM) for Improving the DEM Simulation of Particle-Bed Collisions in Aeolian Sand Transport
    Li, Zhiqiang
    Wang, Yuan
    Zhang, Yang
    Wang, Li
    PARTICULATE SCIENCE AND TECHNOLOGY, 2014, 32 (01) : 86 - 93
  • [22] Investigating Changes in Aeolian Sediment Transport at Coastal Dunes and Sand Trapping Fences: A Field Study on the German Coast
    Eichmanns, Christiane
    Schuttruempf, Holger
    JOURNAL OF MARINE SCIENCE AND ENGINEERING, 2020, 8 (12) : 1 - 27
  • [23] Aeolian sand transport above three desert surfaces in northern China with different characteristics (shifting sand, straw checkerboard, and gravel): field observations
    Ping Lü
    Zhibao Dong
    Xiaoming Ma
    Environmental Earth Sciences, 2016, 75
  • [24] Aeolian sand transport above three desert surfaces in northern China with different characteristics (shifting sand, straw checkerboard, and gravel): field observations
    Lu, Ping
    Dong, Zhibao
    Ma, Xiaoming
    ENVIRONMENTAL EARTH SCIENCES, 2016, 75 (07)
  • [25] Transport of microbial tracers in clean and organically contaminated silica sand in laboratory columns compared with their transport in the field
    Weaver, Louise
    Sinton, Lester W.
    Pang, Liping
    Dann, Rod
    Close, Murray
    SCIENCE OF THE TOTAL ENVIRONMENT, 2013, 443 : 55 - 64
  • [26] Investigation on the static performance of geogrid reinforced aeolian sand railway embankment: Field test and discrete element simulation
    Du, Wei
    Nie, Rusong
    Qi, Yanlu
    Ruan, Bo
    Mo, Fan
    GEOTEXTILES AND GEOMEMBRANES, 2024, 52 (04) : 736 - 752
  • [27] Studying the spatial and temporal changes in aeolian sand transport in a wind tunnel using 3D terrestrial laser scanning
    Wang, Xuesong
    Zhang, Chunlai
    Cen, Songbo
    Dai, Yujie
    Zou, Xueyong
    EUROPEAN JOURNAL OF SOIL SCIENCE, 2020, 71 (05) : 898 - 908
  • [28] Wind-tunnel experiments of Aeolian sand transport reveal a bimodal probability distribution function for the particle lift-off velocities
    Jiang, Chan-Wen
    Parteli, Eric J. R.
    Dong, Zhi-Bao
    Zhang, Zheng-Cai
    Qian, Guang-Qiang
    Luo, Wan-Yin
    Lu, Jun-Feng
    Xiao, Feng-Jun
    Mei, Fan-Min
    CATENA, 2022, 217
  • [29] Performance of sand-emulsion mixes under the effect of field and laboratory environmental conditions
    El-Desouky, Ahmed
    INNOVATIVE INFRASTRUCTURE SOLUTIONS, 2018, 3 (01)
  • [30] Field and laboratory performance of a cold-region sand stabilized with geofiber and synthetic fluid
    Hazirbaba, Kenan
    COLD REGIONS SCIENCE AND TECHNOLOGY, 2017, 135 : 16 - 27