Seismic Performance of Reinforced Concrete Pier with Inside Concrete Filled Steel Tube

被引:1
|
作者
Qiu, Wenliang [1 ]
Jiang, Meng [2 ]
Zhou, Le [1 ]
机构
[1] Dalian Univ Technol, Sch Civil Engn, Dalian 116024, Peoples R China
[2] Dalian Univ Technol, Sch Hydraul Engn, Dalian 116024, Peoples R China
来源
ADVANCES IN STRUCTURES, PTS 1-5 | 2011年 / 163-167卷
关键词
RC-CFT Pier; RC Pier; Nonlinear Seismic Responses; Time-History Analysis;
D O I
10.4028/www.scientific.net/AMR.163-167.4194
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A reinforced concrete column with inside concrete filled steel tube (RC-CFT) has many advantages over reinforced concrete (RC) column, such as higher compression, shear and moment capacity, higher ductility. So this kind of composite column has been used as frame column in buildings. In this paper, the composite columns are used as piers of a continuous bridge to improve the seismic performance. Using nonlinear time-history analysis method and fiber element model, considering elasto-plastic nonlinearity, the nonlinear relationships between lateral load and horizontal displacement of RC-CFT pier and RC pier are calculated, and the seismic behaviors of continuous bridges with the two types of piers are analyzed. Based on the comparison of the results, it is found that the ductility of RC-CFT pier is much larger than RC pier. Under the same intensity earthquakes, the damage of RC-CFT pier is less than the RC pier, and RC-CFT pier is more safe and easy to be repaired after earthquake.
引用
收藏
页码:4194 / +
页数:2
相关论文
共 50 条
  • [41] Experimental study on seismic performance of prefabricated shear wall with concrete filled steel tube
    Chen, Jianwei
    Yan, Wenshang
    Su, Youpo
    Chen, Haibin
    Feng, Xuanming
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2015, 36 : 176 - 184
  • [42] STUDY ON COMPRESSIVE BEARING CAPACITY OF CONCRETE-FILLED SQUARE STEEL TUBE COLUMN REINFORCED BY CIRCULAR STEEL TUBE INSIDE
    Zhang, Yufen
    Zhao, Junhai
    Yuan, Weifeng
    JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT, 2013, 19 (06) : 787 - 795
  • [43] Seismic performance evaluation of rubberized concrete-filled corrugated steel tube piers
    Feng, Mingyang
    Zhang, Linlin
    Liu, Baodong
    Hao, Changshun
    Sun, Haibo
    ARCHIVES OF CIVIL AND MECHANICAL ENGINEERING, 2024, 24 (02)
  • [44] Behaviour of Concrete Filled Steel Tube Reinforced Concrete (CFSTRC) Stub Columns: Experiments
    Li, Yong-Jin
    Ren, Qing-Xin
    Liao, Fei-Yu
    PROGRESS IN STRUCTURE, PTS 1-4, 2012, 166-169 : 859 - +
  • [45] Enhancing the fire-resistant performance of concrete-filled steel tube columns with steel fiber-reinforced concrete
    George, Christo
    Selvan, S. Senthil
    Kumar, V. Sathish
    Murali, G.
    Giri, Jayant
    Makki, Emad
    Sathish, T.
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2024, 20
  • [46] Seismic Performance of Full-Scale Joints Composed by Concrete-Filled Steel Tube Column and Reinforced Concrete Beam with Steel Plate-Stud Connections
    Li, Zhenbao
    Liu, Yashuang
    Ma, Hua
    Wang, Qianqian
    Tang, Zhenyun
    ADVANCES IN CIVIL ENGINEERING, 2019, 2019
  • [47] Experimental study on seismic performance of steel reinforced recycled concrete filled square steel tube composite columns under cyclic loading
    Ma, Hui
    Hu, Jiejiang
    Lai, Zhiqiang
    Liu, Fangda
    Journal of Railway Science and Engineering, 2024, 21 (10) : 4161 - 4174
  • [48] Seismic behavior of steel tube reinforced concrete bridge columns
    Tian, Tian
    Qiu, Wen-liang
    Zhang, Zhe
    STEEL AND COMPOSITE STRUCTURES, 2018, 28 (01): : 63 - 71
  • [49] Seismic performance of a non-through-core concrete between concrete-filled steel tubular columns and reinforced concrete beams
    Ding, Fa-xing
    Yin, Guo-an
    Wang, Li-ping
    Hu, Di
    Chen, Gang-qiang
    THIN-WALLED STRUCTURES, 2017, 110 : 14 - 26