Shoulder abduction diminishes self-reinforcement in transosseous-equivalent rotator cuff repair in both knotted and knotless techniques

被引:2
|
作者
Smith, Geoffrey C. S. [1 ,3 ]
Lam, Patrick H. [2 ,4 ]
机构
[1] St George Hosp, Orthopaed Dept, Sydney, NSW 2217, Australia
[2] St George Hosp, Orthopaed Res Inst, Sydney, NSW, Australia
[3] UNSW, Sydney, NSW, Australia
[4] Univ Sydney, Sydney Med Sch, Northern Clin Sch, Sydney, NSW, Australia
关键词
Rotator cuff; Cuff repair; Double row; Suturebridge; Self-reinforcement; Abduction; DOUBLE-ROW; SINGLE-ROW;
D O I
10.1007/s00167-018-4999-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The self-reinforcement mechanism after double row suturebridge rotator cuff repair generates increasing compressive forces at the tendon footprint with increasing tendon load. Passive range of motion is usually allowed after rotator cuff repair. The mechanism of self-reinforcement could be adversely affected by shoulder abduction. Methods Rotator cuff tears were created ex vivo in nine pairs of ovine shoulders. Two different repair techniques were used. One group was repaired using a double row 'suturebridge' construct with tied horizontal medial row mattress sutures (Knotted repair group). The other group was repaired identically except that medial row knots were not tied (Knotless repair group). Footprint compression was measured at varying amounts of abduction and under tendon loads of 0, 10, 20, 30, 40, 50 and 60N. The rate of increase of contact pressure (degree of self-reinforcement) was calculated for each abduction angle. Results Abduction diminishes footprint contact pressure in both knotted and knotless double row suturebridge constructs. Progressive abduction from 0 to 40 abduction in the knotless group and 0-30 in the knotted group results in a decrease in self-reinforcement. Abduction beyond this does not cause a further decrease in self-reinforcement. There was no difference in the rate of increase of footprint contact pressure at each angle of abduction when comparing the knotted and knotless groups. Conclusion In the post-operative period, high tendon load combined with minimal abduction would be expected to generate the greatest amount of footprint compression which may improve tendon healing. Therefore, to maximize footprint compression the use of abduction pillows should be avoided while early isometric strengthening should be used.
引用
收藏
页码:3818 / 3825
页数:8
相关论文
共 50 条
  • [31] Early Structural and Functional Outcomes for Arthroscopic Double-Row Transosseous-Equivalent Rotator Cuff Repair
    Toussaint, Bruno
    Schnaser, Erik
    Bosley, Jacob
    Lefebvre, Yves
    Gobezie, Reuben
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2011, 39 (06): : 1217 - 1225
  • [32] Author Reply to "Regarding 'Does the Use of Knotted Versus Knotless Transosseous Equivalent Rotator Cuff Repair Technique Influence the Incidence of Retears? A Systematic Review'"
    Kunze, Kyle N.
    Chahla, Jorge
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2020, 36 (07): : 1796 - 1798
  • [33] A Biomechanical Analysis of Point of Failure During Lateral-Row Tensioning in Transosseous-Equivalent Rotator Cuff Repair
    Dierckman, Brian D.
    Goldstein, Jordan L.
    Hammond, Kyle E.
    Karas, Spero G.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2012, 28 (01): : 52 - 58
  • [34] Minimum 10-Year Outcomes of Primary Arthroscopic Transosseous-Equivalent Double-Row Rotator Cuff Repair
    Johannsen, Adam M.
    Arner, Justin W.
    Elrick, Bryant P.
    Nolte, Philip-C.
    Rakowski, Dylan R.
    Horan, Marilee P.
    Millett, Peter J.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2021, 49 (08): : 2035 - 2041
  • [35] Part I: Footprint contact characteristics for a transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique
    Park, Maxwell C.
    ElAttrache, Neal S.
    Tibone, James E.
    Ahmad, Christopher S.
    Jun, Bong-Jae
    Lee, Thay Q.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2007, 16 (04) : 461 - 468
  • [36] A Biomechanical Comparison of 2 Transosseous-Equivalent Double-Row Rotator Cuff Repair Techniques Using Bioabsorbable Anchors: Cyclic Loading and Failure Behavior
    Spang, Jeffrey T.
    Buchmann, Stefan
    Brucker, Peter U.
    Kouloumentas, Panos
    Obst, Tobias
    Schroeder, Manuel
    Burgkart, Rainer
    Imhoff, Andreas B.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2009, 25 (08): : 872 - 879
  • [37] Predictors of outcomes after arthroscopic transosseous equivalent rotator cuff repair in 155 cases: a propensity score weighted analysis of knotted and knotless self-reinforcing repair techniques at a minimum of 2 years (vol 137, pg 1399, 2017)
    Millett, Peter J.
    Espinoza, Chris
    Horan, Marilee P.
    Ho, Charles P.
    Warth, Ryan J.
    Dornan, Grant J.
    Katthagen, J. Christoph
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (12) : 1761 - 1761
  • [38] Biomechanical comparison of single-row, double-row, and transosseous-equivalent repair techniques after healing in an animal rotator cuff tear model
    Quigley, Ryan J.
    Gupta, Akash
    Oh, Joo-Han
    Chung, Kyung-Chil
    McGarry, Michelle H.
    Gupta, Ranjan
    Tibone, James E.
    Lee, Thay Q.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (08) : 1254 - 1260
  • [39] Factors influencing operative time in arthroscopic rotator cuff repair: a comparison of knotless single -row vs. transosseous equivalent dual -row techniques
    Boyd, Jason A.
    Karas, Spero G.
    Urchek, Ryan J.
    Farley, Kevin X.
    Anastasio, Albert T.
    Gottschalk, Michael B.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (07) : S48 - S52
  • [40] Minimum Five-year Outcomes and Clinical Survivorship for Arthroscopic Transosseous-equivalent Double-row Rotator Cuff Repair
    Pogorzelski, Jonas
    Fritz, Erik M.
    Horan, Marilee P.
    Katthagen, J. Christoph
    Hussain, Zaamin B.
    Godin, Jonathan A.
    Millett, Peter J.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2019, 27 (24) : E1093 - E1101