Experimental research on the concentration distribution characteristics of dual-temperature refrigeration system using R290/R600a based on separation condensation

被引:11
|
作者
Chen, Qi [1 ]
Yan, Gang [1 ]
Yu, Jianlin [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Dept Refrigerat & Cryogen Engn, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
Dual-temperature refrigeration; Zeotropic mixture; Concentration distribution; Separation condensation; MIXED-REFRIGERANT; NATURAL REFRIGERANT; COMPOSITION SHIFT; MIXTURE; PERFORMANCE; CASCADE; CIRCULATION; ENERGY; CHARGE; PROPANE/ISOBUTANE;
D O I
10.1016/j.ijrefrig.2021.06.024
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, R290/R600a dual-temperature refrigeration system based on separation condensation approach with two evaporators is experimentally investigated. Refrigerant concentration distribution characteristics of zeotropic mixture R290/R600a are obtained through gas chromatography method. Moreover, the difference between charged concentration and circulating concentration are explored. The results show that circulating refrigerant concentration at different sampling positions deviate from charge refrigerant concentration. The circulating refrigerant concentration of low boiling component R290 at compressor discharge port is 11.9% higher than its charged concentration. Based on the analysis of refrigerant concentration deviation relationship, the experimental prediction correlations on circulating refrigerant concentrations are obtained. In addition, the effects of operation parameters including compressor frequency and ambient temperature on concentration distribution are also investigated. The present work provides a guide for refrigerant circulating concentration prediction and selection of charged refrigerant composition. Furthermore, this could reveal an in-depth understanding on refrigerant circulating concentration distribution characteristics. (c) 2021 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:244 / 253
页数:10
相关论文
共 32 条
  • [21] Theoretical investigation on an ejector-expansion refrigeration cycle using zeotropic mixture R290/R600a for applications in domestic refrigerator/freezers
    Liu, Xiaoqin
    Yu, Jianlin
    Yan, Gang
    APPLIED THERMAL ENGINEERING, 2015, 90 : 703 - 710
  • [22] Energy comparison based on experimental results of a cascade refrigeration system pairing R744 with R134a, R1234ze(E) and the natural refrigerants R290, R1270, R600a
    Cabello, R.
    Andreu-Nacher, A.
    Sandhez, D.
    Llopis, R.
    Vidan-Falomir, F.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 148 : 131 - 142
  • [23] Dynamic characteristics of a climate-adaptive radiant cooling and fresh air supply integrated system with zeotrope R290/R600a
    Zhu, Yutong
    Yin, Yonggao
    ENERGY CONVERSION AND MANAGEMENT, 2024, 317
  • [24] Experimental Study on Intermittent Operation Characteristics of Zeotropic Mixture Partial Condensation Based Dual-temperature Refrigeration System
    Chen, Qi
    Yan, Gang
    Wu, Qingping
    Yu, Jianlin
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2022, 43 (07): : 1815 - 1823
  • [25] Experimental Investigation on Intermittent Operation Characteristics of Dual-Temperature Refrigeration System Using Hydrocarbon Mixture
    Chen, Qi
    Li, Yinsong
    ENERGIES, 2022, 15 (11)
  • [26] Experimental research on a Joule-Thomson refrigeration cycle with mixture R170/R290 for 60 °C low-temperature freezer
    Bai, Tao
    Li, Dawei
    Xie, Hongxu
    Yan, Gang
    Yu, Jianlin
    APPLIED THERMAL ENGINEERING, 2021, 186
  • [27] Thermodynamic analysis and performance optimization on an ultra-low-temperature cascade refrigeration system using refrigerants R290 and R170
    Ji, Shenrui
    Liu, Zhan
    Li, Jiafeng
    Wang, Tao
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2024,
  • [28] Experimental study on Joule-Thomson refrigeration system with R1150/ R290/R601a for ultra-low temperature medical freezer
    Liu, Jiarui
    Yu, Jianlin
    Yan, Gang
    APPLIED THERMAL ENGINEERING, 2024, 255
  • [29] Experimental study on the substitution potential of R1270 and R290 in an instant heat pump for domestic hot water and their temperature distribution characteristics
    Ju, Fujun
    Liu, Qinglei
    Wang, Haoran
    Wu, Jiafeng
    Chen, Yaping
    Du, Yongheng
    Fan, Xiaowei
    Zheng, Huifan
    APPLIED THERMAL ENGINEERING, 2025, 269
  • [30] Experimental research on the explosion characteristics in the indoor and outdoor units of a split air conditioner using the R290 refrigerant
    Zhang, Wang
    Yang, Zhao
    Zhang, Xin
    Lv, Dong
    Jiang, Nan
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 67 : 408 - 417