Vibration suppression with electromagnetic hybrid vibration isolators

被引:3
|
作者
Chen, Fan [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Mech Sci & Engn, Wuhan, Hubei, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
ACTIVE CONTROL;
D O I
10.1088/1757-899X/361/1/012012
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The design and control of a novel electromagnetic hybrid vibration isolator is presented in this paper. In the proposed hybrid vibration isolator configuration, an electromagnetic actuator and a rubber vibration isolator are configured in a parallel structure with the rubber vibration isolator installed inside the mover of the actuator. The magnetic force of the actuator is linearized by magnetic configuration design. Filtered-x least mean square (FxLMS) control algorithm is implemented for hybrid vibration isolation. Experimental results show that the vibration is suppressed significantly with the proposed hybrid vibration isolator and the FxLMS control algorithm.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] An electromagnetic inerter-based vibration suppression device
    Gonzalez-Buelga, A.
    Clare, L. R.
    Neild, S. A.
    Jiang, J. Z.
    Inman, D. J.
    SMART MATERIALS AND STRUCTURES, 2015, 24 (05)
  • [22] Vibration suppression using electromagnetic resonant shunt damper
    Inoue, Tsuyoshi
    Ishida, Yukio
    Sumi, Masaki
    JOURNAL OF VIBRATION AND ACOUSTICS-TRANSACTIONS OF THE ASME, 2008, 130 (04):
  • [23] Research on an Electromagnetic Actuator for Vibration Suppression and Energy Regeneration
    Wei, Wei
    Li, Qiang
    Xu, Fangchao
    Zhang, Xiaoyou
    Jin, Junjie
    Jin, Jiaqi
    Sun, Feng
    ACTUATORS, 2020, 9 (02)
  • [24] Vibration suppression of structure with electromagnetic shunt damping absorber
    Xie, Shilin
    Li, Peichao
    Zhang, Xinong
    Yan, Bo
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2014, 45 (1-4) : 395 - 402
  • [25] Compact isolators deal with vibration and shock
    不详
    HYDRAULICS & PNEUMATICS, 2000, 53 (09) : 8 - 8
  • [26] Static and dynamic stability of pneumatic vibration isolators and systems of isolators
    Ryaboy, Vyacheslav M.
    JOURNAL OF SOUND AND VIBRATION, 2014, 333 (01) : 31 - 51
  • [27] INFLUENCE OF THE PLACEMENT OF VIBRATION ISOLATORS ON THEIR EFFECTIVENESS
    BOCHKAREV, VM
    TARTAKOVSKII, BD
    SOVIET PHYSICS ACOUSTICS-USSR, 1987, 33 (03): : 234 - 236
  • [28] Features of the Power Characteristics of the Vibration Isolators
    Gurova, Elena
    Gurov, Mikhail
    Makarov, Stanislav
    Sergeev, Andrey
    HIGH TECHNOLOGY: RESEARCH AND APPLICATIONS, 2014, 1040 : 678 - 681
  • [29] The dynamic behavior of pneumatic vibration isolators
    Pintado, P.
    Ramiro, C.
    Morales, A. L.
    Nieto, A. J.
    Chicharro, J. M.
    JOURNAL OF VIBRATION AND CONTROL, 2018, 24 (19) : 4563 - 4574
  • [30] Direct force measurements of vibration isolators
    Dickens, JD
    NOISE CONTROL ENGINEERING JOURNAL, 2002, 50 (05) : 176 - 182