Fast Bilateral Breast Coverage With High Spectral and Spatial Resolution (HiSS) MRI at 3T

被引:8
|
作者
Medved, Milica [1 ]
Li, Hui [1 ]
Abe, Hiroyuki [1 ]
Sheth, Deepa [1 ]
Newstead, Gillian M. [1 ]
Olopade, Olufunmilayo I. [2 ]
Giger, Maryellen L. [1 ]
Karczmar, Gregory S. [1 ]
机构
[1] Univ Chicago, Dept Radiol, MC 2026,5841 S Maryland Ave, Chicago, IL 60637 USA
[2] Univ Chicago, Dept Med, 5841 S Maryland Ave, Chicago, IL 60637 USA
基金
美国国家卫生研究院;
关键词
CARCINOMA-IN-SITU; CORE-NEEDLE-BIOPSY; LYMPH-NODE METASTASIS; DUCTAL CARCINOMA; MAGNETIC-RESONANCE; INVASIVE DISEASE; MAMMOGRAPHIC MASSES; OCCULT INVASION; PREDICTORS; CANCER;
D O I
10.1002/jmri.25658
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop and assess a full-coverage, sensitivity encoding (SENSE)-accelerated breast high spatial and spectral resolution (HiSS) magnetic resonance imaging (MRI) within clinically reasonable times as a potential nonenhanced MRI protocol for breast density measurement or breast cancer screening. Materials and Methods: Sixteen women with biopsy-proven cancer or suspicious lesions, and 13 women who were healthy volunteers or were screened for breast cancer, received 3T breast MRI exams, including SENSE-accelerated HiSS MRI, which was implemented as a submillimeter spatial resolution echo-planar spectroscopic imaging (EPSI) sequence. In postprocessing, fat and water resonance peak height and integral images were generated from EPSI data. The postprocessing software was custom-designed, and new algorithms were developed to enable processing of whole-coverage axial HiSS datasets. Water peak height HiSS images were compared to pre-and postcontrast T-1-weighted images. Fat suppression was quantified as parenchymal-to-suppressed-fat signal ratio in HiSS water peak height and nonenhanced T1-weighted images, and artifact levels were scored. Results: Approximately a 4-fold decrease in acquisition speed, with a concurrent 2.5-fold decrease in voxel size, was achieved, with low artifact levels, and with spectral signal-to-noise ratio (SNR) of 45:1. Fat suppression was 1.9 times more effective (P < 0.001) in HiSS images than in T1-weighted images (SPAIR), and HiSS images showed higher SNR in the axilla. HiSS MRI visualized 10 of 13 malignant lesions identified on dynamic contrast-enhanced (DCE)-MRI, and did not require skin removal in postprocessing to generate maximum intensity projection images. Conclusion: We demonstrate full-coverage, SENSE-accelerated breast HiSS MRI within clinically reasonable times, as a potential protocol for breast density measurement or breast cancer screening.
引用
收藏
页码:1341 / 1348
页数:8
相关论文
共 50 条
  • [41] Precision of volumetric assessment of proximal femur microarchitecture from high-resolution 3T MRI
    Alexandra Hotca
    Shreyas Ravichandra
    Artem Mikheev
    Henry Rusinek
    Gregory Chang
    International Journal of Computer Assisted Radiology and Surgery, 2015, 10 : 35 - 43
  • [42] Visualization of the Intimal Flap in Intracranial Arterial Dissection Using High-Resolution 3T MRI
    Uemura, Masahiro
    Terajima, Kenshi
    Suzuki, Yuji
    Watanabe, Masaki
    Akaiwa, Yasuhisa
    Katada, Shinichi
    Okamoto, Kouichirou
    Nishizawa, Masatoyo
    Igarashi, Hironaka
    Nakada, Tsutomu
    JOURNAL OF NEUROIMAGING, 2017, 27 (01) : 29 - 32
  • [43] Quantitative Analysis Using High-Resolution 3T MRI in Acute Intracranial Artery Dissection
    Jung, Seung Chai
    Kim, Ho Sung
    Choi, Choong-Gon
    Kim, Sang Joon
    Lee, Deok Hee
    Suh, Dae Chul
    Kwon, Sun U.
    Kang, Dong-Wha
    Kim, Jong S.
    JOURNAL OF NEUROIMAGING, 2016, 26 (06) : 612 - 617
  • [44] Precision of volumetric assessment of proximal femur microarchitecture from high-resolution 3T MRI
    Hotca, Alexandra
    Ravichandra, Shreyas
    Mikheev, Artem
    Rusinek, Henry
    Chang, Gregory
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (01) : 35 - 43
  • [45] High resolution 3T MRI for the assessment of cervical and superficial cranial arteries in giant cell arteritis
    Markl, Michael
    Uhl, Markus
    Wieben, Oliver
    Neb, Thomas
    Langer, Mathias
    Hennig, Juergen
    Bley, Thorsten A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (02) : 423 - 427
  • [46] Imaging tumor vasculature with a superparamagnetic contrast agent and HiSS (High Spectral and Spatial Resolution) MR imaging
    Karczmar, GS
    River, JN
    Tarlo, KS
    Kellar, K
    Fan, X
    Al-Hallaq, HA
    RADIOLOGY, 1999, 213P : 404 - 404
  • [47] Individually tailored spatial-spectral pulsed CEST MRI for ratiometric mapping ofmyocardial energetic species at 3T
    Ayala, Cindy
    Luo, Huiwen
    Godines, Kevin
    Alghuraibawi, Wissam
    Ahn, Sinyeob
    Rehwald, Wolfgang
    Grissom, William A.
    Vandsburger, Moriel H.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (06) : 2321 - 2333
  • [48] Editorial for "Evaluating High Spatial Resolution Diffusion Kurtosis Imaging at 3T: Reproducibility and Quality of Fit"
    Pullens, Pim
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (04) : 1188 - 1189
  • [49] High spectral and spatial resolution MRI of prostate cancer: a pilot study
    Medved, Milica
    Chatterjee, Aritrick
    Devaraj, Ajit
    Harmath, Carla
    Lee, Grace
    Yousuf, Ambereen
    Antic, Tatjana
    Oto, Aytekin
    Karczmar, Gregory S.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (03) : 1505 - 1513
  • [50] High-resolution 3D diffusion tensor MRI of anesthetized rhesus macaque brain at 3T
    Tounekti, Slimane
    Troalen, Thomas
    Bihan-Poudec, Yann
    Froesel, Mathilda
    Lamberton, Franck
    Ozenne, Valery
    Clery, Justine
    Richard, Nathalie
    Descoteaux, Maxime
    Ben Hamed, Suliann
    Hiba, Bassem
    NEUROIMAGE, 2018, 181 : 149 - 161