共 50 条
Fast Bilateral Breast Coverage With High Spectral and Spatial Resolution (HiSS) MRI at 3T
被引:8
|作者:
Medved, Milica
[1
]
Li, Hui
[1
]
Abe, Hiroyuki
[1
]
Sheth, Deepa
[1
]
Newstead, Gillian M.
[1
]
Olopade, Olufunmilayo I.
[2
]
Giger, Maryellen L.
[1
]
Karczmar, Gregory S.
[1
]
机构:
[1] Univ Chicago, Dept Radiol, MC 2026,5841 S Maryland Ave, Chicago, IL 60637 USA
[2] Univ Chicago, Dept Med, 5841 S Maryland Ave, Chicago, IL 60637 USA
基金:
美国国家卫生研究院;
关键词:
CARCINOMA-IN-SITU;
CORE-NEEDLE-BIOPSY;
LYMPH-NODE METASTASIS;
DUCTAL CARCINOMA;
MAGNETIC-RESONANCE;
INVASIVE DISEASE;
MAMMOGRAPHIC MASSES;
OCCULT INVASION;
PREDICTORS;
CANCER;
D O I:
10.1002/jmri.25658
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Purpose: To develop and assess a full-coverage, sensitivity encoding (SENSE)-accelerated breast high spatial and spectral resolution (HiSS) magnetic resonance imaging (MRI) within clinically reasonable times as a potential nonenhanced MRI protocol for breast density measurement or breast cancer screening. Materials and Methods: Sixteen women with biopsy-proven cancer or suspicious lesions, and 13 women who were healthy volunteers or were screened for breast cancer, received 3T breast MRI exams, including SENSE-accelerated HiSS MRI, which was implemented as a submillimeter spatial resolution echo-planar spectroscopic imaging (EPSI) sequence. In postprocessing, fat and water resonance peak height and integral images were generated from EPSI data. The postprocessing software was custom-designed, and new algorithms were developed to enable processing of whole-coverage axial HiSS datasets. Water peak height HiSS images were compared to pre-and postcontrast T-1-weighted images. Fat suppression was quantified as parenchymal-to-suppressed-fat signal ratio in HiSS water peak height and nonenhanced T1-weighted images, and artifact levels were scored. Results: Approximately a 4-fold decrease in acquisition speed, with a concurrent 2.5-fold decrease in voxel size, was achieved, with low artifact levels, and with spectral signal-to-noise ratio (SNR) of 45:1. Fat suppression was 1.9 times more effective (P < 0.001) in HiSS images than in T1-weighted images (SPAIR), and HiSS images showed higher SNR in the axilla. HiSS MRI visualized 10 of 13 malignant lesions identified on dynamic contrast-enhanced (DCE)-MRI, and did not require skin removal in postprocessing to generate maximum intensity projection images. Conclusion: We demonstrate full-coverage, SENSE-accelerated breast HiSS MRI within clinically reasonable times, as a potential protocol for breast density measurement or breast cancer screening.
引用
收藏
页码:1341 / 1348
页数:8
相关论文