An Experimental Study of the Flow Field Inside the Diffuser Passage of a Laboratory Centrifugal Pump

被引:20
|
作者
Si, Qiaorui [1 ]
Dupont, Patrick [2 ]
Bayeul-Laine, Annie-Claude [3 ]
Dazin, Antoine [3 ]
Roussette, Olivier [3 ]
Yuan, Shouqi [1 ]
机构
[1] Jiangsu Univ, Natl Res Ctr Pumps, Zhenjiang City 212013, Peoples R China
[2] Ecole Cent Lille, UMR CNRS 8107, LML, F-59046 Lille, France
[3] Arts & Metiers Paristech, UMR CNRS 8107, LML, F-59046 Lille, France
基金
中国国家自然科学基金;
关键词
vane-island diffuser; mean flow characteristics; three-hole probe; PIV; flow separation; IMPELLER;
D O I
10.1115/1.4029671
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Measurements are processed on a centrifugal pump model, which works with air and performs with the vane-island type diffuser of a real hydraulic pump, under five flow rates to investigate the internal flow characteristics and their influence on overall pump performance. The mean flow characteristics inside the diffuser are determined by using a miniature three-hole probe connected to an online data acquisition system. The flow structure at the inlet section of the diffuser is analyzed in detail, with a focus on the local pressure loss inside the vaneless gap and incidence angle distributions along the hub-to-shroud direction of the diffuser. Some existing calculations, including leakage effects, are used to evaluate the pressure recovery downstream of the impeller. Furthermore, particle image velocimetry (PIV) measurement results are obtained to help analyze the flow characteristics inside the vane-island diffuser. Each PIV measuring plane is related to one particular diffuser blade-to-blade channel and is analyzed by using the time-averaged method according to seven different relative positions of the impeller. Measurement results show that main loss is produced inside the vaneless part of the diffuser at low flow rates, which might have been caused by the strong rotor-stator interaction. When the impeller flow rate is greater than the diffuser design flow rate, a large fluctuating separated region occurs after the throat of the diffuser on the pressure side. Mean loss originates from the unsteady pressure downstream of the diffuser throat. For better characterization of the separations observed in previous experimental studies, complementary unsteady static pressure measurement campaigns have been conducted on the diffuser blade wall. The unsteadiness revealed by these measurements, as well as theirs effects on the diffuser performance, was then studied.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Experimental Study on Inducement and Development of Flow Instabilities in a Centrifugal Compressor with Different Diffuser Types
    XUE Xiang
    WANG Tong
    Journal of Thermal Science, 2020, 29 (02) : 435 - 444
  • [42] Experimental Study on Inducement and Development of Flow Instabilities in a Centrifugal Compressor with Different Diffuser Types
    Xue Xiang
    Wang Tong
    JOURNAL OF THERMAL SCIENCE, 2020, 29 (02) : 435 - 444
  • [43] Effects of inlet flow field conditions on the performance of centrifugal compressor diffusers: Part 1 - Discrete-passage diffuser
    Filipenco, VG
    Deniz, S
    Johnston, JM
    Greitzer, EM
    Cumpsty, NA
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2000, 122 (01): : 1 - 10
  • [44] Experimental Study on Inducement and Development of Flow Instabilities in a Centrifugal Compressor with Different Diffuser Types
    Xiang Xue
    Tong Wang
    Journal of Thermal Science, 2020, 29 : 435 - 444
  • [45] Flow Field Simulation and Experimental Study of Centrifugal Spinning
    Ye, Hao
    Zhou, Lele
    Zhou, Jing
    Xu, Jingying
    Zhang, Zhao
    Wang, Yaru
    Zhao, Mengyao
    Li, Wanjing
    Yang, Bin
    Li, Xianglong
    FIBERS AND POLYMERS, 2024, 25 (07) : 2751 - 2761
  • [46] EXPERIMENTAL INVESTIGATION ON DIFFUSER ROTATING STALL IN A THREE-STAGE CENTRIFUGAL PUMP
    Takamine, Taiki
    Watanabe, Satoshi
    Furukawa, Daichi
    Watanabe, Hiroyoshi
    Miyagawa, Kazuyoshi
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING, 2017, VOL 1A, 2017,
  • [47] Experimental Analysis on Pressure Fluctuation Characteristics of a Centrifugal Pump with Vaned-Diffuser
    Liu, Houlin
    Xia, Ruichao
    Wang, Kai
    Jing, Yucheng
    He, Xianghui
    WATER, 2020, 12 (01)
  • [48] FLOW INSTABILITY IN OFF DESIGN CONDITION OF VANED AND VANELESS DIFFUSER CENTRIFUGAL PUMP
    Hiramatsu, Hideto
    Shibata, Akiha
    Komaki, Shutaro
    Miyagawa, Kazuyoshi
    Sano, Takeshi
    PROCEEDINGS OF THE ASME/JSME/KSME JOINT FLUIDS ENGINEERING CONFERENCE, 2015, VOL 1A, SYMPOSIA, PT 2, 2016,
  • [49] Impeller wake transport along the diffuser midspan passage of an axial flow pump
    Junyoung Lim
    Moxiao Li
    Seung Jin Song
    Journal of Mechanical Science and Technology, 2025, 39 (1) : 275 - 285
  • [50] Low Field in the Vaned Diffuser of a Centrifugal Pump at Different Vane Setting Angles
    Gaetani, P.
    Boccazzi, A.
    Sala, R.
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2012, 134 (03):