Important Factors for Retrograde Nailing Through Total Knee Arthroplasty: A Cadaveric Study

被引:0
|
作者
Lentine, Brandon [1 ]
Tarka, Mitchell [1 ]
Nelms, Nathaniel J. [2 ]
Russell, Sheila [3 ]
Schottel, Patrick C. [2 ]
Blankstein, Michael [2 ]
机构
[1] Univ Vermont, Dept Orthopaed & Rehabil, Med Ctr, Burlington, VT 05405 USA
[2] Univ Vermont, Dept Orthopaed & Rehabil, Larner Coll Med, Burlington, VT 05405 USA
[3] Univ Vermont, Dept Surg, Larner Coll Med, Burlington, VT 05405 USA
关键词
supracondylar femur fracture; TKA; periprosthetic fracture; retrograde intramedullary nailing; SUPRACONDYLAR FEMUR FRACTURES; FEMORAL COMPONENT; REPLACEMENT; COMPATIBILITY; FLEXION; DESIGN;
D O I
10.1097/BOT.0000000000002221
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: Evaluate how total knee arthroplasty (TKA) implant design, femoral component size, and preoperative knee range of motion affect retrograde femoral nailing. Methods: Cadaveric specimens were prepared for TKA with a single radius (SR) or medial pivot (MP) design and tested with cruciate retaining (CR), cruciate substituting (CS), and posterior stabilizing (PS) 9-mm liners. Knee extension identified the minimum flexion required to pass an opening reamer without impinging on TKA components. The angle between the reamer path and the femoral shaft was calculated from lateral fluoroscopic images. Results: In SR TKA, the average flexion required was 70, 71, and 82 degrees for CR, CS, and PS, respectively. The required flexion in PS was significantly greater (P = 0.03). In MP TKA, the average flexion required was 74, 84, and 123 degrees for CR, CS, and PS, respectively. The required flexion was significantly greater in CS and PS designs (P < 0.0001). Femoral component size did not affect the minimum flexion required. The entry reamer resulted in 9.2 (SR) and 12.5 (MP) degrees of apex anterior deviation. Conclusions: When performing retrograde nailing through either of these TKA designs with a 12-mm opening reamer, at least 70 degrees of knee flexion is required to avoid damage to the polyethylene liner or femoral component. PS implants require significantly more flexion with both TKA designs. Femoral component size did not affect the flexion requirement. Approximately a 10-degree deviation exists between the reamer path and femoral shaft.
引用
收藏
页码:E87 / E91
页数:5
相关论文
共 50 条
  • [21] Subvastus Lateralis Approach to Total Knee Arthroplasty - A Cadaveric Evaluation
    Legault, Josee A.
    Beveridge, Tyler S.
    Johnson, Marjorie I.
    Lanting, Brent A.
    FASEB JOURNAL, 2018, 32 (01):
  • [22] Are We Subluxating Knees in Total Knee Arthroplasty? A Cadaveric Investigation
    Maderbacher, Guenther
    Keshmiri, Armin
    Springorum, Hans R.
    Greimel, Felix
    Grifka, Joachim
    Baier, Clemens
    JOURNAL OF ARTHROPLASTY, 2017, 32 (01): : 263 - 269
  • [23] Risk factors for contralateral total knee arthroplasty after unilateral total knee arthroplasty
    Okamoto, Takuya
    Yamanashi, Yuki
    Ikemoto, Tatsunori
    Miyagawa, Hirofumi
    Ishida, Tomohiro
    Akao, Machiko
    Takata, Takuya
    Kato, Tomohiro
    Kobayakawa, Kyosuke
    Deie, Masataka
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2023, 28 (06) : 1311 - 1316
  • [24] A Cadaveric Study Addressing the Feasibility of Remote Patient Monitoring Prosthesis for Total Knee Arthroplasty
    Cushner, Fred D.
    Schiller, Peter J.
    Mueller, John Kyle P.
    Gross, Jeffrey M.
    Hunter, William L.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (06): : S350 - S354
  • [25] Intraoperative vs. weightbearing patellar kinematics in total knee arthroplasty: A cadaveric study
    Anglin, C.
    Brimacombe, J. M.
    Wilson, D. R.
    Masri, B. A.
    Greidanus, N. V.
    Tonetti, J.
    Hodason, A. J.
    CLINICAL BIOMECHANICS, 2008, 23 (01) : 60 - 70
  • [26] A comparison of registration errors with imageless computer navigation during MIS total knee arthroplasty versus standard incision total knee arthroplasty: a cadaveric study
    Davis, Edward T.
    Pagkalos, Joseph
    Gallie, Price A. M.
    Macgroarty, Kelly
    Waddell, James P.
    Schemitsch, Emil H.
    COMPUTER AIDED SURGERY, 2015, 20 (01) : 7 - 13
  • [27] Ender nailing for supracondylar fracture of the femur after total knee arthroplasty
    Hayakawa, K
    Nakagawa, K
    Ando, K
    Ohashi, H
    JOURNAL OF ARTHROPLASTY, 2003, 18 (07): : 946 - 952
  • [28] Intramedullary Nailing of Tibial Shaft Fractures Distal to Total Knee Arthroplasty
    Haller, Justin M.
    Kubiak, Erik N.
    Spiguel, Andre
    Gardner, Michael J.
    Horwitz, Daniel S.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2014, 28 (12) : E296 - E300
  • [29] Posterior stabilized total knee arthroplasty reproduces natural joint laxity compared to normal in kinematically aligned total knee arthroplasty: a matched pair cadaveric study
    In Jun Koh
    Christen E. Chalmers
    Charles C. Lin
    Soo Bin Park
    Michelle H. McGarry
    Thay Q. Lee
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 119 - 127
  • [30] Kinematically aligned total knee arthroplasty reproduces more native rollback and laxity than mechanically aligned total knee arthroplasty: A matched pair cadaveric study
    Koh, In Jun
    Lin, Charles C.
    Patel, Nilay A.
    Chalmers, Christen E.
    Maniglio, Mauro
    Bin Han, Sung
    McGarry, Michelle H.
    Lee, Thay Q.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2019, 105 (04) : 605 - 611