Important Factors for Retrograde Nailing Through Total Knee Arthroplasty: A Cadaveric Study

被引:0
|
作者
Lentine, Brandon [1 ]
Tarka, Mitchell [1 ]
Nelms, Nathaniel J. [2 ]
Russell, Sheila [3 ]
Schottel, Patrick C. [2 ]
Blankstein, Michael [2 ]
机构
[1] Univ Vermont, Dept Orthopaed & Rehabil, Med Ctr, Burlington, VT 05405 USA
[2] Univ Vermont, Dept Orthopaed & Rehabil, Larner Coll Med, Burlington, VT 05405 USA
[3] Univ Vermont, Dept Surg, Larner Coll Med, Burlington, VT 05405 USA
关键词
supracondylar femur fracture; TKA; periprosthetic fracture; retrograde intramedullary nailing; SUPRACONDYLAR FEMUR FRACTURES; FEMORAL COMPONENT; REPLACEMENT; COMPATIBILITY; FLEXION; DESIGN;
D O I
10.1097/BOT.0000000000002221
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: Evaluate how total knee arthroplasty (TKA) implant design, femoral component size, and preoperative knee range of motion affect retrograde femoral nailing. Methods: Cadaveric specimens were prepared for TKA with a single radius (SR) or medial pivot (MP) design and tested with cruciate retaining (CR), cruciate substituting (CS), and posterior stabilizing (PS) 9-mm liners. Knee extension identified the minimum flexion required to pass an opening reamer without impinging on TKA components. The angle between the reamer path and the femoral shaft was calculated from lateral fluoroscopic images. Results: In SR TKA, the average flexion required was 70, 71, and 82 degrees for CR, CS, and PS, respectively. The required flexion in PS was significantly greater (P = 0.03). In MP TKA, the average flexion required was 74, 84, and 123 degrees for CR, CS, and PS, respectively. The required flexion was significantly greater in CS and PS designs (P < 0.0001). Femoral component size did not affect the minimum flexion required. The entry reamer resulted in 9.2 (SR) and 12.5 (MP) degrees of apex anterior deviation. Conclusions: When performing retrograde nailing through either of these TKA designs with a 12-mm opening reamer, at least 70 degrees of knee flexion is required to avoid damage to the polyethylene liner or femoral component. PS implants require significantly more flexion with both TKA designs. Femoral component size did not affect the flexion requirement. Approximately a 10-degree deviation exists between the reamer path and femoral shaft.
引用
收藏
页码:E87 / E91
页数:5
相关论文
共 50 条
  • [1] Retrograde intramedullary nailing for supracondylar fractures of the femur in total knee arthroplasty
    Wick, M
    Müller, EJ
    Muhr, G
    UNFALLCHIRURG, 2001, 104 (05): : 410 - 413
  • [2] Arthroscopic treatment of a supracondylar femoral fracture with total knee arthroplasty and retrograde femoral nailing
    Schitz, Florian
    Rilk, Sebastian
    Schabus, Rudolf
    ARTHROSKOPIE, 2021, 34 (01) : 74 - 79
  • [3] Retrograde Intramedullary Nailing for Periprosthetic Supracondylar Fractures of the Femur after Total Knee Arthroplasty
    Han, Hyuk-Soo
    Oh, Kyu-Won
    Kang, Seung-Baik
    CLINICS IN ORTHOPEDIC SURGERY, 2009, 1 (04) : 201 - 206
  • [4] Posteromedial Periarticular Injection in Total Knee Arthroplasty: A Cadaveric Study
    Christopher, Zachary K.
    Clarke, Henry D.
    Spangehl, Mark J.
    Bingham, Joshua S.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS GLOBAL RESEARCH AND REVIEWS, 2024, 8 (02):
  • [5] Setting Yourself Up for Success: Retrograde Intramedullary Nailing in Periprosthetic Fractures About Total Knee Arthroplasty
    Medda, Suman
    Snoap, Tyler
    Carroll, Eben A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 : S29 - S32
  • [6] Outcomes of long retrograde intramedullary nailing for periprosthetic supracondylar femoral fractures following total knee arthroplasty
    Sung-San Lee
    Seung-Jae Lim
    Young-Wan Moon
    Jai-Gon Seo
    Archives of Orthopaedic and Trauma Surgery, 2014, 134 : 47 - 52
  • [7] Outcomes of long retrograde intramedullary nailing for periprosthetic supracondylar femoral fractures following total knee arthroplasty
    Lee, Sung-San
    Lim, Seung-Jae
    Moon, Young-Wan
    Seo, Jai-Gon
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2014, 134 (01) : 47 - 52
  • [8] Accuracy of Advanced Active Robot for Total Knee Arthroplasty: A Cadaveric Study
    Lee, Han-Jun
    Park, Kwan Kyu
    Park, Yong-Beom
    Choi, Sung Wook
    Kim, Bong-Oh
    Kim, Seong Hwan
    JOURNAL OF KNEE SURGERY, 2024, 37 (02) : 135 - 141
  • [9] The Biomechanical Effect of Increased Valgus on Total Knee Arthroplasty: A Cadaveric Study
    Bryant, Brandon J.
    Tilan, Justin U.
    McGarry, Michelle H.
    Takenaka, Nobuyuki
    Kim, William C.
    Lee, Thay Q.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (04): : 722 - 726
  • [10] Total knee arthroplasty following intramedullary tibial nailing
    Smith, Evan J.
    Heng, Marilyn
    Bedair, Hany S.
    Melnic, Christopher M.
    KNEE SURGERY & RELATED RESEARCH, 2020, 32 (01)