Quantifying the Knudsen force on heated microbeams: A compact model and direct comparison with measurements

被引:30
|
作者
Nabeth, Jeremy [1 ]
Chigullapalli, Sruti [1 ]
Alexeenko, Alina A. [1 ]
机构
[1] Purdue Univ, Sch Aeronaut & Astronaut, W Lafayette, IN 47907 USA
来源
PHYSICAL REVIEW E | 2011年 / 83卷 / 06期
基金
美国国家科学基金会;
关键词
Compendex;
D O I
10.1103/PhysRevE.83.066306
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
At the microscale, even moderate temperature differences leading to thermal nonequilibrium can result in significant Knudsen forces generated by the energy exchange between gas molecules and solids immersed in a gas. Experimental measurements of the microscale Knudsen force have been reported by Passian et al., Phys. Rev. Lett. 90, 124503 (2003) using heated microcantilevers of atomic force microscope probes. The present study investigates the mechanism and magnitude of Knudsen forces in detail based on numerical solution of the Boltzmann kinetic equation with the ellipsoidal statistical Bhatnagar-Gross-Krook approximation for the collisional relaxation process. A direct comparison between the numerical simulations and experimental measurements is presented. We show that, assuming a fully diffuse interaction of gas molecules with the surfaces of the heated cantilever, simulations agree with measurements for different operating pressures in argon and nitrogen ambients. For the helium ambient the simulations agree with measurements only when an incomplete accommodation is used. A closed-form model for the nondimensional Knudsen force coefficient on a heated microbeam is obtained that can be used for quantifying such forces in analysis and design of microsystems under a wide range of geometrical, thermal, and pressure conditions.
引用
收藏
页数:5
相关论文
共 25 条
  • [21] IMPORTANCE OF GLUCOSE PER SE TO INTRAVENOUS GLUCOSE-TOLERANCE - COMPARISON OF THE MINIMAL-MODEL PREDICTION WITH DIRECT MEASUREMENTS
    ADER, M
    PACINI, G
    YANG, YJ
    BERGMAN, RN
    DIABETES, 1985, 34 (11) : 1092 - 1103
  • [22] A direct comparison of a depth-dependent Radiation stress formulation and a Vortex force formulation within a three-dimensional coastal ocean model
    Moghimi, Saeed
    Klingbeil, Knut
    Graewe, Ulf
    Burchard, Hans
    OCEAN MODELLING, 2013, 70 : 132 - 144
  • [23] Comparison of accuracy of three-dimensional spiral computed tomography, standard radiography, and direct measurements in evaluating facial fracture healing in a rat model
    Özçelik, D
    Hüthüt, I
    Kuran, I
    Bankaoglu, M
    Orhan, Z
    Mayda, AS
    ANNALS OF PLASTIC SURGERY, 2004, 53 (05) : 473 - 480
  • [24] Modeling the effect of cell-associated polymeric fluid layers on force spectroscopy measurements. Part II: Experimental results and comparison with model predictions
    Coldren, Faith M.
    Foteinopoulou, Katerina
    Verbeeten, Wilco M. H.
    Carroll, David L.
    Laso, Manuel
    LANGMUIR, 2008, 24 (17) : 9588 - 9597
  • [25] Lower Limb Joint Load Comparison from Subject Specific Musculoskeletal Model Simulation and Direct Measurements on Different Subject with Instrumented Implant During Normal and Abnormal Gait
    Rodrigues, Carlos
    Correia, Miguel
    Abrantes, Joao
    Rodrigues, Marco
    Nadal, Jurandir
    COMPUTER METHODS, IMAGING AND VISUALIZATION IN BIOMECHANICS AND BIOMEDICAL ENGINEERING II, 2023, 38 : 250 - 270