Quantifying the Knudsen force on heated microbeams: A compact model and direct comparison with measurements

被引:30
|
作者
Nabeth, Jeremy [1 ]
Chigullapalli, Sruti [1 ]
Alexeenko, Alina A. [1 ]
机构
[1] Purdue Univ, Sch Aeronaut & Astronaut, W Lafayette, IN 47907 USA
来源
PHYSICAL REVIEW E | 2011年 / 83卷 / 06期
基金
美国国家科学基金会;
关键词
Compendex;
D O I
10.1103/PhysRevE.83.066306
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
At the microscale, even moderate temperature differences leading to thermal nonequilibrium can result in significant Knudsen forces generated by the energy exchange between gas molecules and solids immersed in a gas. Experimental measurements of the microscale Knudsen force have been reported by Passian et al., Phys. Rev. Lett. 90, 124503 (2003) using heated microcantilevers of atomic force microscope probes. The present study investigates the mechanism and magnitude of Knudsen forces in detail based on numerical solution of the Boltzmann kinetic equation with the ellipsoidal statistical Bhatnagar-Gross-Krook approximation for the collisional relaxation process. A direct comparison between the numerical simulations and experimental measurements is presented. We show that, assuming a fully diffuse interaction of gas molecules with the surfaces of the heated cantilever, simulations agree with measurements for different operating pressures in argon and nitrogen ambients. For the helium ambient the simulations agree with measurements only when an incomplete accommodation is used. A closed-form model for the nondimensional Knudsen force coefficient on a heated microbeam is obtained that can be used for quantifying such forces in analysis and design of microsystems under a wide range of geometrical, thermal, and pressure conditions.
引用
收藏
页数:5
相关论文
共 25 条
  • [1] Negative Knudsen force on heated microbeams
    Zhu, Taishan
    Ye, Wenjing
    Zhang, Jun
    PHYSICAL REVIEW E, 2011, 84 (05)
  • [2] Experimental measurements and numerical simulations of the Knudsen force on a non-uniformly heated beam
    Strongrich, Andrew D.
    O'Neill, William J.
    Cofer, Anthony G.
    Alexeenko, Alina A.
    VACUUM, 2014, 109 : 405 - 416
  • [3] Direct force measurements on a submerged bridge model
    Cigada, A
    Malavasi, S
    Vanali, M
    FLUID STRUCTURE INTERACTION, 2001, 30 : 305 - 314
  • [4] DIRECT WAVE FORCE MEASUREMENTS ON A MODEL TENSION LEG PLATFORM
    VANDIVER, JK
    OCEAN SCIENCE AND ENGINEERING, 1982, 7 (04): : 499 - 517
  • [5] Deformation measurements by ESPI of the surface of a heated mirror and comparison with numerical model
    Languy, Fabian
    Vandenrijt, Jean-Francois
    Saint-Georges, Philippe
    Georges, Marc P.
    OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION X, 2017, 10329
  • [6] COMPARISON OF DATA DERIVED FROM BIOMECHANICS CINEMATOGRAPHY AND DIRECT FORCE MEASUREMENTS
    GROS, HJ
    TERAUDS, J
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1981, 291 : 58 - 61
  • [7] Comparison of Brownian-dynamics-based estimates of polymer tension with direct force measurements
    Arsenault, Mark E.
    Purohit, Prashant K.
    Goldman, Yale E.
    Shuman, Henry
    Bau, Haim H.
    PHYSICAL REVIEW E, 2010, 82 (05):
  • [8] Toward isometric force capabilities evaluation by using a musculoskeletal model: Comparison with direct force measurement
    Hernandez, Vincent
    Rezzoug, Nasser
    Gorce, Philippe
    JOURNAL OF BIOMECHANICS, 2015, 48 (12) : 3178 - 3184
  • [9] Quantifying bite force in coexisting tayassuids and feral suids: a comparison between morphometric functional proxies and in vivo measurements
    Sicuro, Fernando L.
    Oliveira, Luiz Flamarion B.
    Hendges, Carla D.
    Fonseca, Carlos
    PEERJ, 2021, 9
  • [10] Experimental force measurements on a bifurcated endoluminal stent graft model: Comparison with theory
    Sutalo, ID
    Liffman, K
    Lawrence-Brown, MMD
    Semmens, JB
    VASCULAR, 2005, 13 (02) : 98 - 106