PET and parathyroid L-[carbon-11]methionine accumulation in hyperparathyroidism

被引:0
|
作者
Sundin, A
Johansson, C
Hellman, P
Bergstrom, M
Ahlstrom, H
Jacobson, GB
Langstrom, B
Rastad, J
机构
[1] UNIV UPPSALA,PET CTR,UPPSALA,SWEDEN
[2] DEPT DIAGNOST RADIOL,UPPSALA,SWEDEN
[3] DEPT SURG,UPPSALA,SWEDEN
关键词
PET; carbon-11-methionine; parathyroid gland; hyperparathyroidism;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The study was designed to characterize L-[methyl-C-11]methionine accumulation in abnormal parathyroid tissues of hyperparathyroidism (HPT). Methods: Thirty-four patients with primary (n=32) or secondary HPT were investigated with PET before primary or reoperative (n=25) parathyroid surgery. Parathyroid C-11-methionine accumulation was analyzed for integrated uptake values in defined tissue volumes standardized for the injected dose and body weight (SUV), four contiguous pixels of maximal accumulation (SUVhs), SUV multiplied by area of region of interest (SUVr) and by the excised tissue weight (SUVw). Transport rate constants (slope, slope(hs)) were calculated according to Patlak's formula using plasma C-11 activity corrected for C-11-methionine metabolites. Results: True-positive localization was achieved in 85% of patients in whom 81% of the excised parathyroid lesions were visualized; no false-positive results were obtained, Corresponding proportions were 59% and 57% for CT and 55% and 52% for ultrasound, respectively. In the true-positive cases, parathyroid SUV, SUVhs and transport rate constants were consistently higher (p <0.01) than in the thyroid, pharynx-esophagus, neck muscle and apical lung. Parathyroid SUV, SUVhs and SUVr increased with intact serum parathyroid hormone and calcium values (p=0.0001-0.031), and weight of the excised tissue correlated with SUV and SUVhs (p=0.024, 0.044). Parathyroid SUVhs varied strongly with the transport rate constants (p=0.0008), and SUVr as well as s-calcium values differed significantly between parathyroid adenomas (n=11), chief cell hyperplasias(n=13), inadvertent implants (n=3) and parathyroid cancers (n=3). Conclusion: Carbon-11-methionine PET has potential application in preoperative localization and metabolic characterization of abnormal parathyroid tissues in human HPT.
引用
收藏
页码:1766 / 1770
页数:5
相关论文
共 50 条
  • [1] CARBON-11 L-METHIONINE UPTAKE WITH PET AS A PREDICTOR OF PROGNOSIS FOR BRONCHOGENIC-CARCINOMA PATIENTS
    SHIH, WJ
    RYO, UY
    DILLON, ML
    JOURNAL OF NUCLEAR MEDICINE, 1989, 30 (08) : 1420 - 1421
  • [2] Evaluation of the Use of Carbon-11 Methionine PET Scans in Pediatric Patients With Craniopharyngioma
    Laser, B.
    Shulkin, B.
    Indelicato, D. J.
    Merchant, T. E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S163 - S163
  • [3] A feasibility study on L-[1-carbon-11]tyrosine and L-[methyl-carbon-11]methionine to assess liver protein synthesis by PET
    Ishiwata, K
    Enomoto, K
    Sasaki, T
    Elsinga, PH
    Senda, M
    Okazumi, SI
    Isono, K
    Paans, AMJ
    Vaalburg, W
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (02) : 279 - 285
  • [5] Normal biodistribution of carbon-11 methionine in children
    Harris, Sebastian
    Snyder, Scott
    Shulkin, Barry
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [6] Evaluation of children with craniopharyngioma using carbon-11 methionine PET prior to proton therapy
    Laser, Benjamin S.
    Merchant, Thomas E.
    Indelicato, Daniel J.
    Hua, Chia-Ho
    Shulkin, Barry L.
    Snyder, Scott E.
    NEURO-ONCOLOGY, 2013, 15 (04) : 506 - 510
  • [7] Use of carbon-11 nicotine in PET studies
    Hans Lundqvist
    Bengt Långström
    Agneta Nordberg
    European Journal of Nuclear Medicine, 1997, 24 : 825 - 826
  • [8] Use of carbon-11 nicotine in PET studies
    Lundqvist, H
    Langstrom, B
    Nordberg, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (07) : 825 - 826
  • [9] Usefulness of PET/CT with Carbon-11-Labeled Methionine in the Diagnosis of Tertiary Hyperparathyroidism
    Kolodziej, Maciej
    Saracyn, Marek
    Lubas, Arkadiusz
    Dziuk, Miroslaw
    Durma, Adam Daniel
    Smoszna, Jerzy
    Zelichowski, Grzegorz
    Niemczyk, Stanislaw
    Kaminski, Grzegorz
    NUTRIENTS, 2023, 15 (01)
  • [10] Is [11C]-choline PET CT superior to [11C]-methionine PET CT in detecting of parathyroid adenomas in primary hyperparathyroidism?
    Lenschow, Christina
    Hendricks, Anne
    Buck, Andreas
    Werner, Rudolf A.
    Schlegel, Nicolas