Dependence of the efficiency of a capillary column in gas chromatography on the relative pressure of the carrier gas

被引:3
|
作者
Korolev, A. A. [1 ]
Shiryaeva, V. E. [1 ]
Popova, T. P. [1 ]
Kurganov, A. A. [1 ]
机构
[1] Russian Acad Sci, AV Topchiev Petrochem Synth Inst, Moscow 119991, Russia
关键词
capillary gas chromatography; relative presssure; efficiency; capillary column; SPEED;
D O I
10.1134/S1061934811020080
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The effect of relative pressure on the efficiency of an open capillary column in gas chromatography was studied. It was shown that the relative pressure was not the only parameter determining the column efficiency. The pressure drop in the column is an additional parameter. At high values of relative pressure, the pressure drop in the column becomes determining for the column efficiency. The smallest value of a height equivalent to a theoretical plate (HETP) is achieved at the minimum values of the pressure drop and the relative pressure, which is accompanied by a decrease in the optimal flow rate of the carrier gas and an increase in the time of determination. The maximum improvement in the column efficiency is determined by the column properties and can exceed 12.5%, that is, the value predicted by Cramers for open capillary columns.
引用
收藏
页码:184 / 188
页数:5
相关论文
共 50 条
  • [41] Efficiency of monolithic capillary columns in high-pressure gas chromatography
    A. Yu. Kanat’eva
    A. A. Korolev
    M. E. Dianov
    A. A. Kurganov
    Russian Journal of Physical Chemistry A, 2013, 87 : 1905 - 1911
  • [42] Development of an Atmospheric Pressure Glow Discharge Detector for Capillary Column Gas Chromatography
    Hyo J. Kim
    Young A. Woo
    Jong S. Kang
    Susanna S. Anderson
    Edward H. Piepmeier
    Microchimica Acta, 2000, 134 : 1 - 7
  • [43] Evaluation of column performance in constant pressure and constant flow capillary gas chromatography
    Blumberg, LM
    Wilson, WH
    Klee, MS
    JOURNAL OF CHROMATOGRAPHY A, 1999, 842 (1-2) : 15 - 28
  • [44] Development of an atmospheric pressure glow discharge detector for capillary column gas chromatography
    Kim, HJ
    Woo, YA
    Kang, JS
    Anderson, SS
    Piepmeier, EH
    MIKROCHIMICA ACTA, 2000, 134 (1-2) : 1 - 7
  • [45] Efficiency of monolithic capillary columns in high-pressure gas chromatography
    Kanat'eva, A. Yu
    Korolev, A. A.
    Dianov, M. E.
    Kurganov, A. A.
    RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY A, 2013, 87 (11) : 1905 - 1911
  • [46] DEPENDENCE OF THE SPLITTING RATIO ON COLUMN TEMPERATURE IN SPLIT INJECTION CAPILLARY GAS-CHROMATOGRAPHY
    GROB, K
    NEUKOM, HP
    JOURNAL OF CHROMATOGRAPHY, 1982, 236 (02): : 297 - 306
  • [47] MIXTURE OF AMMONIA AND HELIUM AS A CARRIER GAS FOR CAPILLARY GAS-CHROMATOGRAPHY
    ABDELREHIM, M
    ZHANG, L
    HASSAN, M
    EHRSSON, H
    JOURNAL OF MICROCOLUMN SEPARATIONS, 1993, 5 (06) : 537 - 542
  • [48] The influence of the carrier gas on retention in capillary gas-solid chromatography
    Berezkin, VG
    Malyukova, IV
    Alishoev, VR
    deZeeuw, J
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1996, 19 (05): : 272 - 276
  • [49] Investigation of the role of the carrier gas in capillary gas-solid chromatography
    Berezkin, VG
    Malyukova, IV
    Alishoev, VR
    RUSSIAN CHEMICAL BULLETIN, 1996, 45 (03) : 587 - 593
  • [50] Nitrous oxide as carrier gas in capillary gas-liquid chromatography
    Berezkin, VG
    Sorokina, EY
    Malyukova, IV
    Orlov, EN
    Antipov, EM
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1998, 21 (07): : 407 - 410