Three-dimensional pore space quantification of apple tissue using X-ray computed microtomography

被引:170
|
作者
Mendoza, Fernando
Verboven, Pieter
Mebatsion, Hibru K.
Kerckhofs, Greet
Wevers, Martine
Nicolai, Bart
机构
[1] Katholieke Univ Leuven, Fac Biosci Engn, BIOSYST, B-3001 Louvain, Belgium
[2] Katholieke Univ Leuven, Dept Met & Mat Engn, MTM, Mat Performance & Non Destruct Evaluat, B-3001 Louvain, Belgium
关键词
apple; 3D image processing; medial axis analysis; microstructure; representative elementary volume; X-ray microtomography;
D O I
10.1007/s00425-007-0504-4
中图分类号
Q94 [植物学];
学科分类号
071001 ;
摘要
The microstructure and the connectivity of the pore space are important variables for better understanding of the complex gas transport phenomena that occur in plant tissues. In this study, we present an experimental procedure for image acquisition and image processing to quantitatively characterize in 3D the pore space of apple tissues (Malus domestica Borkh.) for two cultivars (Jonagold and Braeburn) taken from the fleshy part of the cortex using X-ray computer microtomography. Preliminary sensitivity analyses were performed to determine the effect of the resolution and the volume size (REV, representative elementary volume analysis) on the computed porosity of apple samples. For comparison among cultivars, geometrical properties such as porosity, specific surface area, number of disconnected pore volumes and their distribution parameters were extracted and analyzed in triplicate based on the 3D skeletonization of the pore space (medial axis analysis). The results showed that microtomography provides a resolution at the micrometer level to quantitatively analyze and characterize the 3D topology of the pore space in apple tissue. The computed porosity was confirmed to be highly dependent of the resolution used, and the minimum REV of the cortical flesh of apple fruit was estimated to be 1.3 mm(3). Comparisons among the two cultivars using a resolution of 8.5 mu m with a minimum REV cube showed that in spite of the complexity and variability of the pore space network observed in Jonagold and Braeburn apples, the extracted parameters from the medial axis were significantly different (P-value < 0.05). Medial axis parameters showed potential to differentiate the microstructure between the two evaluated apple cultivars.
引用
收藏
页码:559 / 570
页数:12
相关论文
共 50 条
  • [21] X-ray microtomography application in pore space reservoir rock
    Oliveira, M. F. S.
    Lima, I.
    Borghi, L.
    Lopes, R. T.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (07) : 1376 - 1378
  • [22] In Situ Visualization and Quantification of Three-Dimensional Root System Architecture and Growth Using X-Ray Computed Tomography
    Koebernick, Nicolai
    Weller, Ulrich
    Huber, Katrin
    Schlueter, Steffen
    Vogel, Hans-Joerg
    Jahn, Reinhold
    Vereecken, Harry
    Vetterlein, Doris
    VADOSE ZONE JOURNAL, 2014, 13 (08)
  • [23] A robust method for high-precision quantification of the complex three-dimensional vasculatures acquired by X-ray microtomography
    Tan, Hai
    Wang, Dadong
    Li, Rongxin
    Sun, Changming
    Lagerstrom, Ryan
    He, You
    Xue, Yanling
    Xiao, Tiqiao
    JOURNAL OF SYNCHROTRON RADIATION, 2016, 23 : 1216 - 1226
  • [24] Two and three-dimensional morphometric analysis of trabecular bone using X-ray microtomography (μCT)
    da Silva, Alessandro Márcio Hakme
    Alves, José Marcos
    da Silva, Orivaldo Lopes
    da Silva Junior, Nelson Ferreira
    Revista Brasileira de Engenharia Biomedica, 2014, 30 (02): : 93 - 101
  • [25] Extracellular matrix deposition and scaffold biodegradation in an in vitro three-dimensional model of bone by X-ray computed microtomography
    Ruggiu, Alessandra
    Tortelli, Federico
    Komlev, Vladimir S.
    Peyrin, Francoise
    Cancedda, Ranieri
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2014, 8 (07) : 557 - 565
  • [26] Three-dimensional zinc mapping inside aluminum foams using synchrotron X-ray microtomography
    Ohgaki, T.
    Takami, Y.
    Toda, H.
    Kobayashi, T.
    Suzuki, Y.
    Uesugi, K.
    Makii, K.
    Takagi, T.
    Aruga, Y.
    PRICM 6: SIXTH PACIFIC RIM INTERNATIONAL CONFERENCE ON ADVANCED MATERIALS AND PROCESSING, PTS 1-3, 2007, 561-565 : 1677 - +
  • [27] Three-dimensional measurement and simulation of the dewatering behaviour of flocs and sediments using X-ray microtomography
    Jia, X.
    Williams, R. A.
    Selomulya, C.
    JOURNAL OF THE SOUTH AFRICAN INSTITUTE OF MINING AND METALLURGY, 2008, 108 (10): : 607 - 612
  • [28] Three-dimensional monochromatic x-ray computed tomography using synchrotron radiation
    Saito, T
    Kudo, H
    Takeda, T
    Itai, Y
    Tokumori, K
    Toyofuku, F
    Hyodo, K
    Ando, M
    Nishimura, K
    Uyama, C
    OPTICAL ENGINEERING, 1998, 37 (08) : 2258 - 2268
  • [29] Three-dimensional characterization of powder particles using X-ray computed tomography
    Zhou, Xin
    Dai, Ning
    Cheng, Xiaosheng
    Thompson, Adam
    Leach, Richard
    ADDITIVE MANUFACTURING, 2021, 40
  • [30] Three-dimensional characterization of powder particles using X-ray computed tomography
    Zhou, Xin
    Dai, Ning
    Cheng, Xiaosheng
    Thompson, Adam
    Leach, Richard
    Additive Manufacturing, 2021, 40