Augmented reality surgical navigation with ultrasound-assisted registration for pedicle screw placement: a pilot study

被引:87
|
作者
Ma, Longfei [1 ]
Zhao, Zhe [2 ]
Chen, Fang [1 ]
Zhang, Boyu [1 ]
Fu, Ligong [2 ]
Liao, Hongen [1 ]
机构
[1] Tsinghua Univ, Sch Med, Dept Biomed Engn, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Beijing Tsinghua Changgung Hosp, Dept Orthoped, Beijing 102218, Peoples R China
基金
中国国家自然科学基金;
关键词
Augmented reality; Surgical navigation; Pedicle screw placement; Ultrasound assistance; LUMBAR SPINE; IMAGE GUIDANCE; SURGERY; ACCURACY; FLUOROSCOPY; INJECTIONS; SNAPSHOTS; INSERTION; OVERLAY; SYSTEM;
D O I
10.1007/s11548-017-1652-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We present a novel augmented reality (AR) surgical navigation system based on ultrasound-assisted registration for pedicle screw placement. This system provides the clinically desired targeting accuracy and reduces radiation exposure. Ultrasound (US) is used to perform registration between preoperative computed tomography (CT) images and patient, and the registration is performed by least-squares fitting of these two three-dimensional (3D) point sets of anatomical landmarks taken from US and CT images. An integral videography overlay device is calibrated to accurately display naked-eye 3D images for surgical navigation. We use a 3.0-mm Kirschner wire (K-wire) instead of a pedicle screw in this study, and the K-wire is calibrated to obtain its orientation and tip location. Based on the above registration and calibration, naked-eye 3D images of the planning path and the spine are superimposed onto patient in situ using our AR navigation system. Simultaneously, a 3D image of the K-wire is overlaid accurately on the real one to guide the insertion procedure. The targeting accuracy is evaluated postoperatively by performing a CT scan. An agar phantom experiment was performed. Eight K-wires were inserted successfully after US-assisted registration, and the mean targeting error and angle error were 3.35 mm and , respectively. Furthermore, an additional sheep cadaver experiment was performed. Four K-wires were inserted successfully. The mean targeting error was 3.79 mm and the mean angle error was , and US-assisted registration yielded better targeting results than skin markers-based registration (targeting errors: 2.41 vs. 5.18 mm, angle errors: vs. . Experimental outcomes demonstrate that the proposed navigation system has acceptable targeting accuracy. In particular, the proposed navigation method reduces repeated radiation exposure to the patient and surgeons. Therefore, it has promising prospects for clinical use.
引用
收藏
页码:2205 / 2215
页数:11
相关论文
共 50 条
  • [21] Augmented reality surgical navigation with accurate CBCT-patient registration for dental implant placement
    Ma, Longfei
    Jiang, Weipeng
    Zhang, Boyu
    Qu, Xiaofeng
    Ning, Guochen
    Zhang, Xinran
    Liao, Hongen
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2019, 57 (01) : 47 - 57
  • [22] A Spine Robotic-Assisted Navigation System for Pedicle Screw Placement
    Chen, Hsuan-Yu
    Xiao, Xiu-Yun
    Chen, Chih-Wei
    Chou, Hao-Kai
    Sung, Chen-Yu
    Lin, Feng Huei
    Chen, Po-Quang
    Wong, Tze-hong
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (159):
  • [23] Surgical safety of cervical pedicle screw placement with computer navigation system
    Nobuyuki Shimokawa
    Toshihiro Takami
    Neurosurgical Review, 2017, 40 : 251 - 258
  • [24] Surgical safety of cervical pedicle screw placement with computer navigation system
    Shimokawa, Nobuyuki
    Takami, Toshihiro
    NEUROSURGICAL REVIEW, 2017, 40 (02) : 251 - 258
  • [25] Augmented reality-based navigation increases precision of pedicle screw insertion
    Dennler, Cyrill
    Jaberg, Laurenz
    Spirig, Jose
    Agten, Christoph
    Gotschi, Tobias
    Furnstahl, Philipp
    Farshad, Mazda
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [26] Augmented reality-based navigation increases precision of pedicle screw insertion
    Cyrill Dennler
    Laurenz Jaberg
    José Spirig
    Christoph Agten
    Tobias Götschi
    Philipp Fürnstahl
    Mazda Farshad
    Journal of Orthopaedic Surgery and Research, 15
  • [27] Augmented reality-based surgical navigation of pelvic screw placement: an ex-vivo experimental feasibility study
    Heining, Sandro-Michael
    Raykov, Vladislav
    Wolff, Oliver
    Alkadhi, Hatem
    Pape, Hans-Christoph
    Wanner, Guido A.
    PATIENT SAFETY IN SURGERY, 2024, 18 (01)
  • [28] Augmented reality-based surgical navigation of pelvic screw placement: an ex-vivo experimental feasibility study
    Sandro-Michael Heining
    Vladislav Raykov
    Oliver Wolff
    Hatem Alkadhi
    Hans-Christoph Pape
    Guido A. Wanner
    Patient Safety in Surgery, 18
  • [29] Vertebral templates combined with augmented reality technology for guidance of pedicle screw placement
    Wu, Zhanglei
    Wang, Shuyi
    Chen, Zan
    Zhang, Can
    Shao, Hongran
    Fu, Xiaoni
    Ma, Bangfeng
    Yu, Jiaqi
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2022, 15 (12): : 414 - 422
  • [30] An Augmented Reality-Based Interaction Scheme for Robotic Pedicle Screw Placement
    Voros, Viktor
    Li, Ruixuan
    Davoodi, Ayoob
    Wybaillie, Gauthier
    Vander Poorten, Emmanuel
    Niu, Kenan
    JOURNAL OF IMAGING, 2022, 8 (10)