The impact of vessel and catheter position on the measurement accuracy in catheter-based quantitative coronary angiography

被引:9
|
作者
Wunderlich, W
Roehrig, B
Fischer, F
Arntz, HR
Agrawal, R
Morguet, A
Schultheiss, HP
Horstkotte, D
机构
[1] Free Univ Berlin, Hosp Benjamin Franklin, Dept Med 2, Berlin, Germany
[2] Free Univ Berlin, Hosp Benjamin Franklin, Dept Cardiol, Berlin, Germany
[3] Free Univ Berlin, Hosp Benjamin Franklin, Dept Pulmol, Berlin, Germany
来源
关键词
angiography; catheter calibration; out-of-plane magnification error; quantitative coronary;
D O I
10.1023/A:1006067117225
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The calculation of absolute artery dimensions in quantitative coronary angiography is usually carried out by catheter calibration. It is based on the proportional comparison of the dimension of the imaged artery segment to the dimension of the imaged angiographic catheter of known size. This calibration method presumes an identical radiographic magnification between angiographic catheter and artery segment of interest. However, due to the different intrathoracic location of both objects the radiographic magnification or calibration factor is often not identical for a given angiographic projection. The aim of this study was to quantify the magnification error (out-of-plane magnification error) for the major coronary artery segments imaged in frequently used angiographic projections. Methods: The intrathoracic spatial location of 468 coronary segments (RCA 196, LAD 156, LCX 116) and their respective coronary catheters were established with biplane angiography and known imaging geometry data. The error in the radiographic magnification or calibration factor was then calculated for ail 936 monoplane projections using the spatial coordinates and imaging geometry data. Results: The mean magnitude of magnification error was 4% within all 936 measurements. The magnitude and direction of error varied with the lesion localization and the angiographic projection angle (range -12.6% to +10.6%). The error characteristics could be described with six typical error groups by stratifying the data according to the three main coronaries and two angiographic planes. In 24% of measurements, the magnification error exceeded the 5.2% error limit acceptable for reference vessel sizing. Measurements of left coronary arteries were mainly affected by it. Conclusion: The magnification error contributes to the calibration error in measuring arterial dimensions by quantitative angiography. This error may affect the reliability of clinical studies and the proper sizing of interventional devices. These findings could be used to improve current error correction algorithms in order to reduce the effect of the magnification error in measuring arterial dimensions.
引用
下载
收藏
页码:217 / 227
页数:11
相关论文
共 50 条
  • [31] Catheter-based radiotherapy to inhibit restenosis after coronary stenting
    Teirstein, PS
    Massullo, V
    Jani, S
    Popma, JJ
    Mintz, GS
    Russo, RJ
    Schatz, RA
    Guarneri, EM
    Steuterman, S
    Morris, NB
    Leon, MB
    Tripuraneni, P
    NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (24): : 1697 - 1703
  • [33] Measurement of Thrombolysis Enhanced by EkoSonic Catheter-Based Endovascular Therapy
    Hannah, Alexander
    Noble-Vranish, Misty L.
    Genstler, Curtis
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 2233 - 2237
  • [34] CATHETER-BASED ATRIAL DEFIBRILLATION
    WHARTON, JM
    JOHNSON, EE
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (05): : 1058 - 1066
  • [35] Debulking prior to coronary stenting: A promising synergy in catheter-based coronary interventions
    Moses, J
    Moussa, I
    JOURNAL OF INVASIVE CARDIOLOGY, 1998, 10 : 48B - 52B
  • [36] The impact of cardiac CT on the appropriate utilization of catheter coronary angiography
    Philipp Wagdi
    Hatem Alkadhi
    The International Journal of Cardiovascular Imaging, 2010, 26 : 333 - 344
  • [37] The impact of cardiac CT on the appropriate utilization of catheter coronary angiography
    Wagdi, Philipp
    Alkadhi, Hatem
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (03): : 333 - 344
  • [38] Coronary Angiography: Catheter Based or Computed Tomography Based Reply
    de Feyter, Pim J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (25) : 2406 - 2406
  • [39] Intravenous Tenectaplase for Treatment of Cerebral Emboli Occurring during Catheter-Based Angiography
    Nunna, Ravi S.
    Smith, Caitlyn
    Kumar, Nitish
    Gruber, Max
    Pfeiffer, Kimberley
    Siddiq, Farhan
    Qureshi, Adnan I.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2023, 34 (05) : 931 - 933
  • [40] Correction of rotational distortion for catheter-based en face OCT and OCT angiography
    Ahsen, Osman O.
    Lee, Hsiang-Chieh
    Giacomelli, Michael G.
    Wang, Zhao
    Liang, Kaicheng
    Tsai, Tsung-Han
    Potsaid, Benjamin
    Mashimo, Hiroshi
    Fujimoto, James G.
    OPTICS LETTERS, 2014, 39 (20) : 5973 - 5976