Hand-Powered Microfluidics for Parallel Droplet Digital Loop-Mediated Isothermal Amplification Assays

被引:21
|
作者
Yuan, Hao [1 ,2 ]
Tian, Jingxuan [3 ]
Chao, Youchuang [3 ]
Chien, Yuh-Shiuan [2 ]
Luo, Ren-Hao [2 ]
Guo, Jun-Yu [2 ]
Li, Shanshan [4 ]
Chou, Yi-Ju [2 ]
Shum, Ho Cheung [3 ]
Chen, Chien-Fu [2 ]
机构
[1] Southwest Jiaotong Univ, Sch Life Sci & Engn, Chengdu 610031, Sichuan, Peoples R China
[2] Natl Taiwan Univ, Inst Appl Mech, Taipei 106, Taiwan
[3] Univ Hong Kong, Dept Mech Engn, Pok Fu Lam, Hong Kong, Peoples R China
[4] Univ Hong Kong, Dept Clin Oncol, Shenzhen Hosp, Shenzhen 518009, Peoples R China
来源
ACS SENSORS | 2021年 / 6卷 / 08期
关键词
droplet digital loop-mediated isothermal amplification; droplet microfluidics; pathogen detection; compartmentalization; nucleic acid quantification; droplet generation; multi-sample detection; LAMP; DNA;
D O I
10.1021/acssensors.1c00184
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Droplet digital loop-mediated isothermal amplification (ddLAMP) is an important assay for pathogen detection due to its high accuracy, specificity, and ability to quantify nucleic acids. However, performing ddLAMP requires expensive instrumentation and the need for highly trained personnel with expertise in microfluidics. To make ddLAMP more accessible, a ddLAMP assay is developed, featuring significantly decreased operational difficulty and instrumentation requirements. The proposed assay consists of three simplified steps: (1) droplet generation step, in which a LAMP mixture can be emulsified just by manually pulling a syringe connected to a microfluidic device. In this step, for the first time, we verify that highly monodispersed droplets can be generated with unstable flow rates or pressures, allowing untrained personnel to operate the microfluidic device and perform ddLAMP assay; (2) heating step, in which the droplets are isothermally heated in a water bath, which can be found in most laboratories; and (3) result analysis step, in which the ddLAMP result can be determined using only a fluorescence microscopy and an open-source analyzing software. Throughout the process, no droplet microfluidic expertise or equipment is required. More importantly, the proposed system enables multiple samples to be processed simultaneously with a detection limit of 10 copies/mu L. The test is simple and intuitive to operate in most laboratories for multi-sample detection, significantly enhancing the accessibility and detection throughput of the ddLAMP technique.
引用
收藏
页码:2868 / 2874
页数:7
相关论文
共 50 条
  • [11] CENTRIFUGAL STEP EMULSIFICATION MICROFLUIDICS SUPPORTING DROPLET DIGITAL LOOP-MEDIATED ISOTHERMAL AMPLIFICATION (LAMP) OF SARS-COV-2 N GENE
    Shi, Zhi
    Dong, Nan
    Lai, Xiaochen
    Yu, Haixia
    Li, Dachao
    2021 21ST INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), 2021, : 976 - 979
  • [12] Loop-Mediated Isothermal Amplification in Schistosomiasis
    Garcia-Bernalt Diego, Juan
    Fernandez-Soto, Pedro
    Febrer-Sendra, Begona
    Crego-Vicente, Beatriz
    Muro, Antonio
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (03) : 1 - 13
  • [13] Loop-mediated isothermal amplification of DNA
    Notomi, Tsugunori
    Okayama, Hiroto
    Masubuchi, Harumi
    Yonekawa, Toshihiro
    Watanabe, Keiko
    Amino, Nobuyuki
    Hase, Tetsu
    NUCLEIC ACIDS RESEARCH, 2000, 28 (12)
  • [14] Improved Performance of Loop-Mediated Isothermal Amplification Assays via Swarm Priming
    Martineau, Rhett L.
    Murray, Sarah A.
    Ci, Shufang
    Gao, Weimin
    Chao, Shih-hui
    Meldrum, Deirdre R.
    ANALYTICAL CHEMISTRY, 2017, 89 (01) : 625 - 632
  • [15] Loop-Mediated Isothermal Amplification Assays for Detecting Yersinia pseudotuberculosis in Milk Powders
    Zhang, Hongwei
    Feng, Jinsong
    Xue, Rui
    Du, Xin-Jun
    Lu, Xiaonan
    Wang, Shuo
    JOURNAL OF FOOD SCIENCE, 2014, 79 (05) : M967 - M971
  • [16] Microfluidic continuous flow digital loop-mediated isothermal amplification (LAMP)
    Rane, Tushar D.
    Chen, Liben
    Zec, Helena C.
    Wang, Tza-Huei
    LAB ON A CHIP, 2015, 15 (03) : 776 - 782
  • [17] Detection of Phytophthora infestans by Loop-Mediated Isothermal Amplification, Real-Time LAMP, and Droplet Digital PCR
    Ristaino, Jean B.
    Saville, Amanda C.
    Paul, Rajesh
    Cooper, Donald C.
    Wei, Qingshan
    PLANT DISEASE, 2020, 104 (03) : 708 - 716
  • [18] Detecting amplicons of loop-mediated isothermal amplification
    Shirato, Kazuya
    MICROBIOLOGY AND IMMUNOLOGY, 2019, 63 (10) : 407 - 412
  • [19] Applications of Loop-Mediated Isothermal DNA Amplification
    Fu, Shijun
    Qu, Guanggang
    Guo, Shijin
    Ma, Lin
    Zhang, Na
    Zhang, Songlin
    Gao, Sanyang
    Shen, Zhiqiang
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2011, 163 (07) : 845 - 850
  • [20] Applications of Loop-Mediated Isothermal DNA Amplification
    Shijun Fu
    Guanggang Qu
    Shijin Guo
    Lin Ma
    Na Zhang
    Songlin Zhang
    Sanyang Gao
    Zhiqiang Shen
    Applied Biochemistry and Biotechnology, 2011, 163 : 845 - 850