Accuracy of Areal Measurement in the Periocular Region Using Stereophotogrammetry

被引:9
|
作者
Liu, Jinhua [1 ,2 ]
Guo, Yongwei [3 ]
Arakelyan, Marat [1 ,2 ]
Rokohl, Alexander C. [1 ,2 ]
Heindl, Ludwig M. [1 ,2 ,4 ]
机构
[1] Univ Cologne, Dept Ophthalmol, Kerpener Str 62, D-50937 Cologne, Germany
[2] Univ Hosp Cologne, Fac Med, Kerpener Str 62, D-50937 Cologne, Germany
[3] Zhejiang Univ, Sch Med, Affiliated Hosp 2, Ctr Eye, Hangzhou, Zhejiang, Peoples R China
[4] Aachen Bonn Cologne Duesseldorf, Head Oclular Oncol & Ophthalm Plast & Reconstruct, Cologne, Germany
关键词
3-DIMENSIONAL ANTHROPOMETRIC EVALUATION; FACIAL MORPHOLOGY; PHOTOGRAMMETRY; REPRODUCIBILITY; RELIABILITY; SYSTEM;
D O I
10.1016/j.joms.2020.12.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this study was to evaluate the accuracy of stereophotogrammetric area measurements in the periocular region and analyze the differences between the 2 genders and 2 races. Materials and Methods: A prospective study was performed on healthy young volunteers. The sample was composed of 20 Caucasians and 20 Chinese volunteers. Five objects of different sizes (0.16 cm(2), 0.36 cm(2), 0.64 cm(2), 1.44 cm(2), and 2.56 cm(2)) were placed at 7 periocular locations. Caliper and the VECTRA M3 system were used for direct and 3D stereophotogrammetric analysis. Accuracy and differences in 2 different genders and 2 races were analyzed. The predictor variable was the mean absolute deviation between the 2 measurement methods. The nonparametric Wilcoxon signed-rank test or paired t-test was used to test the statistical differences between the 2 measurement methods. A P value < .05 was considered statistically significant. Results: The mean difference between the 2 measurements of all objects was less than 0.02 cm(2), nonparametric Wilcoxon signed-rank test or paired t-test showed no statistically significant (P > .05, respectively) differences between the 2 measurement methods, except for object 1 and object 5 (endocanthion). Chinese and female volunteers tend to have lower accuracy than Caucasians and male volunteers. Conclusions: Three-dimensional stereophotogrammetry is highly accurate for area measurements in the periocular region. (C) 2020 American Association of Oral and Maxillofacial Surgeons
引用
收藏
页码:1106.e1 / 1106.e9
页数:9
相关论文
共 50 条
  • [1] Reliability of Stereophotogrammetry for Area Measurement in the Periocular Region
    Jinhua Liu
    Alexander C. Rokohl
    Yongwei Guo
    Senmao Li
    Xiaoyi Hou
    Wanlin Fan
    Maxim Formuzal
    Ming Lin
    Ludwig M. Heindl
    [J]. Aesthetic Plastic Surgery, 2021, 45 : 1601 - 1610
  • [2] Reliability of Stereophotogrammetry for Area Measurement in the Periocular Region
    Liu, Jinhua
    Rokohl, Alexander C.
    Guo, Yongwei
    Li, Senmao
    Hou, Xiaoyi
    Fan, Wanlin
    Formuzal, Maxim
    Lin, Ming
    Heindl, Ludwig M.
    [J]. AESTHETIC PLASTIC SURGERY, 2021, 45 (04) : 1601 - 1610
  • [3] Reliability of periocular anthropometry using three-dimensional digital stereophotogrammetry
    Guo, Yongwei
    Rokohl, Alexander C.
    Schaub, Friederike
    Hou, Xiaoyi
    Liu, Jinhua
    Ruan, Yue
    Jia, Renbing
    Koch, Konrad R.
    Heindl, Ludwig M.
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2019, 257 (11) : 2517 - 2531
  • [4] Reliability of periocular anthropometry using three-dimensional digital stereophotogrammetry
    Yongwei Guo
    Alexander C. Rokohl
    Friederike Schaub
    Xiaoyi Hou
    Jinhua Liu
    Yue Ruan
    Renbing Jia
    Konrad R. Koch
    Ludwig M. Heindl
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2019, 257 : 2517 - 2531
  • [5] ACCURACY OF A VOLUME FRACTION MEASUREMENT USING AREAL IMAGE-ANALYSIS
    SHI, DX
    WINSLOW, D
    [J]. JOURNAL OF TESTING AND EVALUATION, 1991, 19 (03) : 210 - 213
  • [6] Biometric Identification Using the Periocular Region
    Kumar, K. Kishore
    Rao, P. Trinatha
    [J]. INFORMATION AND COMMUNICATION TECHNOLOGY FOR INTELLIGENT SYSTEMS (ICTIS 2017) - VOL 2, 2018, 84 : 619 - 628
  • [7] Accuracy of periocular lesion assessment using telemedicine
    Kang, Swan
    Dehabadi, Mohammad
    Sim, Dawn A.
    Thomas, Peter B. M.
    Ewusi, Doris Appiah
    Ezra, Daniel
    [J]. BMJ HEALTH & CARE INFORMATICS, 2021, 28 (01)
  • [8] MEASUREMENT ACCURACY IN ACETABULAR CUP WEAR - 3 RETROSPECTIVE METHODS COMPARED WITH ROENTGEN STEREOPHOTOGRAMMETRY
    ILCHMANN, T
    MJOBERG, B
    WINGSTRAND, H
    [J]. JOURNAL OF ARTHROPLASTY, 1995, 10 (05): : 636 - 642
  • [9] LBP Based Biometric Identification using the Periocular Region
    Kumar, K. Kishore
    Pavani, Movva
    [J]. 2017 8TH IEEE ANNUAL INFORMATION TECHNOLOGY, ELECTRONICS AND MOBILE COMMUNICATION CONFERENCE (IEMCON), 2017, : 204 - 209
  • [10] Expression Recognition Using the Periocular Region: A Feasibility Study
    Alonso-Fernandez, Fernando
    Bigun, Josef
    Englund, Cristofer
    [J]. 2018 14TH INTERNATIONAL CONFERENCE ON SIGNAL IMAGE TECHNOLOGY & INTERNET BASED SYSTEMS (SITIS), 2018, : 536 - 541