In vivo performance of a phospholipid-coated bioerodable elastomeric graft for small-diameter vascular applications

被引:88
|
作者
Soletti, Lorenzo [1 ,2 ,3 ,4 ]
Nieponice, Alejandro [1 ,3 ,4 ]
Hong, Yi [1 ,3 ,4 ]
Ye, Sang-Ho [1 ,3 ,4 ]
Stankus, John J. [3 ,5 ]
Wagner, William R. [1 ,2 ,3 ,4 ,5 ]
Vorp, David A. [1 ,2 ,3 ,4 ]
机构
[1] Univ Pittsburgh, Dept Surg, Pittsburgh, PA 15219 USA
[2] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA 15219 USA
[3] Univ Pittsburgh, McGowan Inst Regenerat Med, Pittsburgh, PA 15219 USA
[4] Univ Pittsburgh, Ctr Vasc Remodeling & Regenerat, Pittsburgh, PA 15219 USA
[5] Univ Pittsburgh, Dept Chem Engn, Pittsburgh, PA 15219 USA
基金
美国国家卫生研究院;
关键词
vascular tissue engineering; rat aortic interposition graft; small diameter vascular graft; electrospinning; poly(ester urethane)urea; biomimetic surface modification; SUBMUCOSA SIS; SMOOTH-MUSCLE; BLOOD-VESSEL; SCAFFOLDS; POLYMER; ARTERY; POLYURETHANE; DEGRADATION; FABRICATION; COMPLIANT;
D O I
10.1002/jbm.a.32997
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
There remains a great need for vascular substitutes for small-diameter applications. The use of an elastomeric biodegradable material, enabling acute antithrombogenicity and long-term in vivo remodeling, could be beneficial for this purpose. Conduits (1.3 mm internal diameter) were obtained by electrospinning biodegradable poly(ester urethane) urea (PEUU), and by luminally immobilizing a non-thrombogenic, 2-methacryloyloxyethyl phosphorylcholine (MPC) copolymer. Platelet adhesion was characterized in vitro after contact with ovine blood. The conduits were implanted as aortic interposition grafts in the rat for 4, 8, 12, and 24 weeks. Surface treatment resulted in a 10-fold decrease in platelet adhesion compared to untreated material. Patency at 8 weeks was 92% for the coated grafts compared to 40% for the non-coated grafts. Histology at 8 and 12 weeks demonstrated formation of cellularized neotissue consisting of aligned collagen and elastin. The lumen of the grafts was confluent with cells qualitatively aligned in the direction of blood flow. Immunohisto-chemistry suggested the presence of smooth muscle cells in the medial layer of the neotissue and endothelial cells lining the lumen. Mechanically, the grafts were less compliant than rat aortas prior to implantation (4.5 +/- 2.0 x 10(-4) mmHg(-1) vs. 14.2 +/- 1.1 x 10(-4) mmHg(-1), respectively), then after 4 weeks in vivo they approximated native values, but subsequently became stiffer again at later time points. The novel coated grafts exhibited promising antithrombogenic and mechanical properties for small-diameter arterial revascularization. Further evaluation in vivo will be required to demonstrate complete remodeling of the graft into a native-like artery. (C) 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 96A: 436-448, 2011.
引用
收藏
页码:436 / 448
页数:13
相关论文
共 50 条
  • [1] In vivo evaluation of an elastomeric small-diameter vascular graft reinforced with a highly flexible Nitinol mesh
    Soldani, Giorgio
    Murzi, Michele
    Faita, Francesco
    Di Lascio, Nicole
    Al Kayal, Tamer
    Spano, Raffaele
    Canciani, Barbara
    Losi, Paola
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2019, 107 (04) : 951 - 964
  • [2] A novel polyurethane modified with biomacromolecules for small-diameter vascular graft applications
    Shiva Asadpour
    Hamid Yeganeh
    Jafar Ai
    Hossein Ghanbari
    [J]. Journal of Materials Science, 2018, 53 : 9913 - 9927
  • [3] A novel polyurethane modified with biomacromolecules for small-diameter vascular graft applications
    Asadpour, Shiva
    Yeganeh, Hamid
    Ai, Jafar
    Ghanbari, Hossein
    [J]. JOURNAL OF MATERIALS SCIENCE, 2018, 53 (14) : 9913 - 9927
  • [4] Preparation and mechanical performance of small-diameter PHBHHx vascular graft by electrospinning
    Gao, Jing
    Guo, Huiwen
    Tian, Shunzhu
    Qiao, Yansha
    Han, Jiarui
    Li, Yuling
    Wang, Lu
    [J]. INTERNATIONAL JOURNAL OF POLYMERIC MATERIALS AND POLYMERIC BIOMATERIALS, 2019, 68 (10) : 575 - 581
  • [5] Therapeutic strategies for small-diameter vascular graft calcification
    Teng, Yanjiao
    Xu, Yang
    Lv, Pengfei
    Song, Lin
    Yang, Jianing
    Wang, Xiudan
    Guo, Xiaoqin
    Wang, Shufang
    Hou, Shike
    Lv, Qi
    Shi, Jie
    [J]. CHEMICAL ENGINEERING JOURNAL, 2024, 487
  • [6] Develop A Small-diameter Vascular Graft With Amniotic Membrane
    Wang, B.
    [J]. TISSUE ENGINEERING PART A, 2023, 29 (9-10)
  • [7] Future Perspectives in Small-Diameter Vascular Graft Engineering
    Mallis, Panagiotis
    Kostakis, Alkiviadis
    Stavropoulos-Giokas, Catherine
    Michalopoulos, Efstathios
    [J]. BIOENGINEERING-BASEL, 2020, 7 (04): : 1 - 40
  • [8] Small-diameter vascular graft prostheses: Current status
    Bos, GW
    Poot, AA
    Beugeling, T
    van Aken, WG
    Feijen, J
    [J]. ARCHIVES OF PHYSIOLOGY AND BIOCHEMISTRY, 1998, 106 (02) : 100 - 115
  • [9] Tailored electrospun small-diameter graft for vascular prosthesis
    Ferrari, Pier Francesco
    Aliakbarian, Bahar
    Lagazzo, Alberto
    Tamayol, Ali
    Palombo, Domenico
    Perego, Patrizia
    [J]. INTERNATIONAL JOURNAL OF POLYMERIC MATERIALS AND POLYMERIC BIOMATERIALS, 2017, 66 (12) : 635 - 643
  • [10] Effect of porosity on small-diameter vascular graft healing
    Contreras, MA
    Quist, WC
    LoGerfo, FW
    [J]. MICROSURGERY, 2000, 20 (01) : 15 - 21