In vivo evaluation of an elastomeric small-diameter vascular graft reinforced with a highly flexible Nitinol mesh

被引:3
|
作者
Soldani, Giorgio [1 ]
Murzi, Michele [2 ]
Faita, Francesco [3 ]
Di Lascio, Nicole [3 ,4 ]
Al Kayal, Tamer [1 ]
Spano, Raffaele [5 ,6 ]
Canciani, Barbara [5 ,7 ]
Losi, Paola [1 ]
机构
[1] CNR, Ist Fisiol Clin, Lab Biomat & Graft Technol, I-54100 Massa, Italy
[2] FTGM, I-54100 Massa, Italy
[3] CNR, Ist Fisiol Clin, Lab Expt Ultrasound, I-56127 Pisa, Italy
[4] Scuola Super Sant Anna, Inst Life Sci, I-56127 Pisa, Italy
[5] Univ Genoa, Lab Regenerat Med, DIMES, I-16132 Genoa, Italy
[6] Ist Italiano Tecnol, Dept Drug Discovery & Dev, Via Morego 30, I-16163 Genoa, Italy
[7] Univ Milan, Dept Biomed Sci Hlth, Via Mangiagalli 31, I-20133 Milan, Italy
关键词
small-diameter vascular graft; poly(ether-urethane)-polydimethylsiloxane; flexible nitinol mesh; in vivo evaluation; endothelialization; CORONARY-ARTERY-DISEASE; PROSTHESES; DESIGN; TISSUE;
D O I
10.1002/jbm.b.34189
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Highly porous small-diameter vascular grafts (SDVGs) prepared with elastomeric materials such as poly(ether urethane) (PEtU)-polydimethylsiloxane (PEtU-PDMS) are capable to biodegrade but may develop aneurismal dilatation. Through a compliance/patency assessment with ultrasound techniques, the current study investigated the functionality, in terms of patency and endothelialization, of a highly flexible and porous Nitinol mesh incorporated into PEtU-PDMS SDVGs in a sheep carotid model. Nitinol-PEtU-PDMS grafts with an internal diameter (ID) of 4 mm were manufactured by spray, phase-inversion technique. Compliance tests were performed by ultrasound (US) imaging using a high-resolution ultrasound diagnostic system. Ten adult sheep were implanted with 7 cm long grafts. The results of this study demonstrated an almost complete neointima luminal coverage in transmurally porous grafts reinforced with the Nitinol meshes after 6 months of implantation. Additionally, ultrasound has been used to quantitatively assess and monitor hemodynamic variables in an experimental model of synthetic vascular graft replacement. The use of reinforced PEtU-PDMS grafts may accelerate the endothelialization process of relatively long grafts, such as those needed for aortocoronary bypass. (c) 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 951-964, 2019.
引用
收藏
页码:951 / 964
页数:14
相关论文
共 50 条
  • [1] In vivo evaluation of polyurethane-PDMS based small diameter vascular grafts reinforced with a Nitinol mesh
    Soldani, G.
    [J]. JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2014, 8 : 424 - 424
  • [2] In vivo performance of a phospholipid-coated bioerodable elastomeric graft for small-diameter vascular applications
    Soletti, Lorenzo
    Nieponice, Alejandro
    Hong, Yi
    Ye, Sang-Ho
    Stankus, John J.
    Wagner, William R.
    Vorp, David A.
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2011, 96A (02) : 436 - 448
  • [3] Chitosan-based hydrogels for developing a small-diameter vascular graft: in vitro and in vivo evaluation
    Aussel, A.
    Thebaud, N. B.
    Berard, X.
    Brizzi, V.
    Delmond, S.
    Bareille, R.
    Siadous, R.
    James, C.
    Ripoche, J.
    Durand, M.
    Montembault, A.
    Burdin, B.
    Letourneur, D.
    L'Heureux, N.
    David, L.
    Bordenave, L.
    [J]. BIOMEDICAL MATERIALS, 2017, 12 (06)
  • [4] BIOSPUN VASCULAR GRAFTS: IN VIVO EVALUATION OF A NOVEL SMALL-DIAMETER BIOACTIVE NANOFIBROUS VASCULAR GRAFT FOR ARTERIAL RECONSTRUCTION
    Contreras, Mauricio Antonio
    Phaneuf, Mathew Douglas
    Wu, Shengqian
    Bide, Martin J.
    LoGerfo, Frank W.
    [J]. FASEB JOURNAL, 2008, 22
  • [5] Therapeutic strategies for small-diameter vascular graft calcification
    Teng, Yanjiao
    Xu, Yang
    Lv, Pengfei
    Song, Lin
    Yang, Jianing
    Wang, Xiudan
    Guo, Xiaoqin
    Wang, Shufang
    Hou, Shike
    Lv, Qi
    Shi, Jie
    [J]. CHEMICAL ENGINEERING JOURNAL, 2024, 487
  • [6] Develop A Small-diameter Vascular Graft With Amniotic Membrane
    Wang, B.
    [J]. TISSUE ENGINEERING PART A, 2023, 29 (9-10)
  • [7] Future Perspectives in Small-Diameter Vascular Graft Engineering
    Mallis, Panagiotis
    Kostakis, Alkiviadis
    Stavropoulos-Giokas, Catherine
    Michalopoulos, Efstathios
    [J]. BIOENGINEERING-BASEL, 2020, 7 (04): : 1 - 40
  • [8] Small-diameter vascular graft prostheses: Current status
    Bos, GW
    Poot, AA
    Beugeling, T
    van Aken, WG
    Feijen, J
    [J]. ARCHIVES OF PHYSIOLOGY AND BIOCHEMISTRY, 1998, 106 (02) : 100 - 115
  • [9] Tailored electrospun small-diameter graft for vascular prosthesis
    Ferrari, Pier Francesco
    Aliakbarian, Bahar
    Lagazzo, Alberto
    Tamayol, Ali
    Palombo, Domenico
    Perego, Patrizia
    [J]. INTERNATIONAL JOURNAL OF POLYMERIC MATERIALS AND POLYMERIC BIOMATERIALS, 2017, 66 (12) : 635 - 643
  • [10] Effect of porosity on small-diameter vascular graft healing
    Contreras, MA
    Quist, WC
    LoGerfo, FW
    [J]. MICROSURGERY, 2000, 20 (01) : 15 - 21