An investigation of voltage sags by a phasor methodology

被引:0
|
作者
Yao, K [1 ]
Koval, D [1 ]
Xu, W [1 ]
Salmon, J [1 ]
机构
[1] Univ Alberta, Dept Elect & Comp Engn, Edmonton, AB T6G 2G7, Canada
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The occurrence of voltage anomalies in the electric delivery system can disrupt the performance of computers and the processes they control. The occurrence of single line to ground faults on the utility's primary lines (i.e., the most frequent type of utility faults) has a significant impact on the voltage magnitude and phase angle as seen by all the customers connected to the primary circuit. The type of transformer connection (e.g., wye ungrounded - delta) linking a customer to the primary circuit alters the primary voltage sags during primary circuit faults that seen at the customers service entrance. This paper will present the phase and line-to-line voltage sag basic equations for an ungrounded-delta transformer connection due to primary distribution single line phase faults. The basic equations presented provide the framework for evaluating the voltage sags for nine different transformer connections. The significant impact of grounded and ungrounded transformer connections on the magnitude and phase angle of the primary and secondary phase and line voltages will be revealed.
引用
收藏
页码:689 / 692
页数:4
相关论文
共 50 条
  • [1] Methodology for evaluation of voltage sags
    Garcia Quintero, Edwin
    Fuster Roig, Vicente
    [J]. REVISTA FACULTAD DE INGENIERIA-UNIVERSIDAD DE ANTIOQUIA, 2010, (53): : 196 - 204
  • [2] On Phasor Estimation for Voltage Sags Detection in a Smart Grid Context
    Amirat, Yassine
    Oubrahim, Zakarya
    Benbouzid, Mohamed
    [J]. 2015 IEEE 24TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2015, : 1351 - 1356
  • [3] Methodology for Quantification of Equipment Trips due to Voltage Sags
    Bodnar, Roman
    Otcenasova, Alena
    Regula, Michal
    Repak, Michal
    [J]. 2016 ELEKTRO 11TH INTERNATIONAL CONFERENCE, 2016, : 264 - 268
  • [4] Methodology for Determination of the Number of Equipment Malfunctions Due to Voltage Sags
    Otcenasova, Alena
    Bodnar, Roman
    Regula, Michal
    Hoger, Marek
    Repak, Michal
    [J]. ENERGIES, 2017, 10 (03)
  • [5] Methodology for Probabilistic Estimation of Equipment Trips due to Voltage Sags
    Bodnar, Roman
    Otcenasova, Alena
    Regula, Michal
    Altus, Juraj
    [J]. PROCEEDINGS OF THE 8TH INTERNATIONAL SCIENTIFIC SYMPOSIUM ON ELECTRICAL POWER ENGINEERING (ELEKTROENERGETIKA 2015), 2015, : 496 - 499
  • [6] Methodology for robust monitoring of voltage sags based on equipment trip probabilities
    Woolley, N. C.
    Avendano-Mora, J. M.
    Milanovic, J. V.
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2012, 90 : 107 - 116
  • [7] Methodology for assessment of financial losses due to voltage sags and short interruptions
    Chan, Jhan Yhee
    Milanovic, Jovica V.
    [J]. PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON ELECTRICAL POWER QUALITY AND UTILISATION, VOLS 1 AND 2, 2007, : 494 - 499
  • [8] Investigation on Voltage Sags Caused by DG Anti-Islanding Protection
    Trindade, Fernanda C. L.
    do Nascimento, Klaus V.
    Vieira, Jose C. M.
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (02) : 972 - 980
  • [9] Investigation on Voltage Sags Caused by DG Anti-Islanding Protection
    Trindade, Fernanda
    Vieira, Jose Carlos
    Nascimento, Klaus
    [J]. 2014 IEEE PES GENERAL MEETING - CONFERENCE & EXPOSITION, 2014,
  • [10] Investigation of electric drive system responses to lightning related voltage sags
    Yin, YX
    Wu, AY
    Blackburn, T
    [J]. CONFERENCE RECORD OF 1999 ANNUAL PULP AND PAPER INDUSTRY TECHNICAL CONFERENCE, 1999, : 83 - 93