Methodology for Determination of the Number of Equipment Malfunctions Due to Voltage Sags

被引:9
|
作者
Otcenasova, Alena [1 ]
Bodnar, Roman [2 ]
Regula, Michal [1 ]
Hoger, Marek [1 ]
Repak, Michal [1 ]
机构
[1] Univ Zilina, Dept Power Elect Syst, Fac Elect Engn, Univ 1, Zilina 01026, Slovakia
[2] Elect Distribut Co, Rajcianke 2927-8, Zilina 01047, Slovakia
关键词
power quality; voltage sag; sensitivity of equipment; probability of equipment trip; PROBABILISTIC ASSESSMENT; POWER QUALITY; SENSITIVITY; INTERRUPTIONS;
D O I
10.3390/en10030401
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This article deals with the assessment of the reliability of sensitive equipment due to voltage sags. The most frequent problems of power quality are voltage sags. Equipment that cannot withstand short-term voltage sag is defined as sensitive device. Sensitivity of such equipment can be described by the voltage-tolerance curves. A device (generator) to generate voltage sags (also interruptions) with duration at least 1 ms has been designed and developed for this purpose. Equipment sensitive to voltage sags was tested using this generator. Overall, five types of sensitive equipment were tested: personal computers, fluorescent lamps, drives with speed control, programmable logic controllers, and contactors. The measured sensitivity curves of these devices have been used to determine the number of trips (failures) due to voltage sags. Two probabilistic methods (general probability method and cumulative probability method) to determine probability of equipment failure occurrence are used. These methods were applied to real node in the distribution system with its actual performance of voltage sags/swells. The calculations also contain different levels of sensitivity of the sensitive equipment.
引用
收藏
页数:26
相关论文
共 50 条
  • [1] Methodology for Determination of the Number of Equipment Malfunctions due to Voltage Quality
    Bodnar, Roman
    Otcenasova, Alena
    Regula, Michal
    Repak, Michal
    2016 IEEE 16TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (EEEIC), 2016,
  • [2] Methodology for Quantification of Equipment Trips due to Voltage Sags
    Bodnar, Roman
    Otcenasova, Alena
    Regula, Michal
    Repak, Michal
    2016 ELEKTRO 11TH INTERNATIONAL CONFERENCE, 2016, : 264 - 268
  • [3] Methodology for Probabilistic Estimation of Equipment Trips due to Voltage Sags
    Bodnar, Roman
    Otcenasova, Alena
    Regula, Michal
    Altus, Juraj
    PROCEEDINGS OF THE 8TH INTERNATIONAL SCIENTIFIC SYMPOSIUM ON ELECTRICAL POWER ENGINEERING (ELEKTROENERGETIKA 2015), 2015, : 496 - 499
  • [4] Predicting Equipment Outages Due to Voltage Sags
    dos Santos, Andre
    Correia de Barros, Maria Teresa
    IEEE TRANSACTIONS ON POWER DELIVERY, 2016, 31 (04) : 1683 - 1691
  • [5] Estimation of sensitive equipment disruptions due to voltage sags
    Lu, Chan-Nan
    Shen, Cheng-Chieh
    IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (02) : 1132 - 1137
  • [6] Probabilistic assessment of equipment trips due to voltage sags
    Gupta, CP
    Milanovic, JV
    IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (02) : 711 - 718
  • [7] Estimation of sensitive equipment disruptions due to voltage sags
    Lu, Chan-Nan
    Shen, Cheng-Chieh
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 268 - 268
  • [8] Probabilistic methods for counting equipment trips due to voltage sags
    Gupta, C. P.
    Milanovic, J. V.
    2006 INTERNATIONAL CONFERENCE ON PROBABILISTIC METHODS APPLIED TO POWER SYSTEMS, VOLS 1 AND 2, 2006, : 743 - 750
  • [9] Methodology for robust monitoring of voltage sags based on equipment trip probabilities
    Woolley, N. C.
    Avendano-Mora, J. M.
    Milanovic, J. V.
    ELECTRIC POWER SYSTEMS RESEARCH, 2012, 90 : 107 - 116
  • [10] Are voltage sags destroying equipment?
    Bendre, Ashish
    Divan, Deepak
    Kranz, William
    Brumsickle, William E.
    IEEE INDUSTRY APPLICATIONS MAGAZINE, 2006, 12 (04) : 12 - 21