Noninvasive tracking of cardiac embryonic stem cells in vivo using magnetic resonance imaging techniques

被引:62
|
作者
Ebert, Steven N.
Taylor, David G.
Nguyen, Ha-Long
Kodack, David P.
Beyers, Ronald J.
Xu, Yaqin
Yang, Zequan
French, Brent A.
机构
[1] Univ Cent Florida, Burnett Coll Biomed Sci, Biomol Sci Ctr, Orlando, FL 32816 USA
[2] Georgetown Univ, Med Ctr, Dept Pharmacol, Washington, DC 20007 USA
[3] Univ Virginia Hlth Syst, Dept Biomed Engn, Charlottesville, VA USA
关键词
cell transplantation; in vivo tracking; mouse; embryonic stem cells; heart;
D O I
10.1634/stemcells.2007-0216
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Despite rapid advances in the stem cell field, the ability to identify and track transplanted or migrating stem cells in vivo is limited. To overcome this limitation, we used magnetic resonance imaging (MRI) to detect and follow transplanted stem cells over a period of 28 days in mice using an established myocardial infarction model. Pluripotent mouse embryonic stem (mES) cells were expanded and induced to differentiate into beating cardiomyocytes in vitro. The cardiac-differentiated mES cells were then loaded with superparamagnetic fluorescent microspheres (1.63 mu m in diameter) and transplanted into ischemic myocardium immediately following ligation and subsequent reperfusion of the left anterior descending coronary artery. To identify the transplanted stem cells in vivo, MRI was performed using a Varian Inova 4.7 Tesla scanner. Our results show that (a) the cardiac-differentiated mES were effectively loaded with superparamagnetic microspheres in vitro, (b) the microsphere-loaded mES cells continued to beat in culture prior to transplantation, (c) the transplanted mES cells were readily detected in the heart in vivo using noninvasive MRI techniques, (d) the transplanted stem cells were detected in ischemic myocardium for the entire 28-day duration of the study as confirmed by MRI and post-mortem histological analyses, and (e) concurrent functional MRI indicated typical loss of cardiac function, although significant amelioration of remodeling was noted after 28 days in hearts that received transplanted stem cells. These results demonstrate that it is feasible to simultaneously track transplanted stem cells and monitor cardiac function in vivo over an extended period using noninvasive MRI techniques.
引用
收藏
页码:2936 / 2944
页数:9
相关论文
共 50 条
  • [41] Magnetic Resonance Imaging of Human Dental Pulp Stem Cells In Vitro and In Vivo
    Struys, T.
    Ketkar-Atre, A.
    Gervois, P.
    Leten, C.
    Hilkens, P.
    Martens, W.
    Bronckaers, A.
    Dresselaers, T.
    Politis, C.
    Lambrichts, I.
    Himmelreich, U.
    CELL TRANSPLANTATION, 2013, 22 (10) : 1813 - 1829
  • [42] Visualization of exosomes from mesenchymal stem cells in vivo by magnetic resonance imaging
    Liu, Tianqi
    Zhu, Yurong
    Zhao, Ruiting
    Wei, Xinhua
    Xin, Xuegang
    MAGNETIC RESONANCE IMAGING, 2020, 68 : 75 - 82
  • [43] Modern techniques for stem cells in vivo imaging
    Meleshina, A. V.
    Cherkasova, E. I.
    Shirmanova, M. V.
    Khrapichev, A. A.
    Dudenkova, V. V.
    Zagaynova, E. V.
    SOVREMENNYE TEHNOLOGII V MEDICINE, 2015, 7 (04) : 174 - 186
  • [44] Noninvasive Cardiac Flow Assessment Using High Speed Magnetic Resonance Fluid Motion Tracking
    Wong, Kelvin Kian Loong
    Kelso, Richard Malcolm
    Worthley, Stephen Grant
    Sanders, Prashanthan
    Mazumdar, Jagannath
    Abbott, Derek
    PLOS ONE, 2009, 4 (05):
  • [45] Optimizing techniques for tracking transplanted stem cells in vivo
    Brazelton, TR
    Blau, HM
    STEM CELLS, 2005, 23 (09) : 1251 - 1265
  • [46] In vivo detection limits of magnetically labeled embryonic stem cells in the rat brain using high-field (17.6 T) magnetic resonance imaging
    Stroh, A
    Faber, C
    Neuberger, T
    Lorenz, P
    Sieland, K
    Jakob, PM
    Webb, A
    Pilgrimm, H
    Schober, R
    Pohl, EE
    Zimmer, C
    NEUROIMAGE, 2005, 24 (03) : 635 - 645
  • [47] Noninvasive tracking of human mesenchymal stem cells in vivo using imaging-visible microcapsules and triple-fusion reporter
    Fu, Y.
    Mease, R.
    Chen, Y.
    Solaiyappan, M.
    Cook, J.
    Kraitchman, D. L.
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (04) : 667 - 668
  • [48] Sensitivity of magnetic resonance imaging of dendritic cells for in vivo tracking of cellular cancer vaccines
    Verdijk, Pauline
    Scheenen, Tom W. J.
    Lesterhuis, W. Joost
    Gambarota, Giulio
    Veltien, Andor A.
    Walczak, Piotr
    Scharenborg, Nicole M.
    Bulte, Jeff W. M.
    Punt, Cornelis J. A.
    Heerschap, Arend
    Figdorl, Carl G.
    de Vries, I. Jolanda M.
    INTERNATIONAL JOURNAL OF CANCER, 2007, 120 (05) : 978 - 984
  • [49] Dual contrast magnetic resonance imaging tracking of iron-labeled cells in vivo
    Wu, Shengyong
    Zhang, Longjiang
    Zhong, Jianhui
    Zhang, Zhuoli
    CYTOTHERAPY, 2010, 12 (07) : 859 - 869
  • [50] In vivo magnetic resonance imaging of stem cell viability
    Suzuki, Yoriyasu
    Cunningham, Charles H.
    Yeung, Alan C.
    Robbins, Robert
    Conolly, Steven
    Yang, Phillip C.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 158A - 158A