Analysis of Indoor Thermal Comfort of Different Air-conditioning Systems

被引:0
|
作者
Zhao, Jianhui [1 ]
Xu, Hongyi [1 ]
Wu, Yehao [1 ]
Lei, Chao [1 ]
机构
[1] Xian Univ Sci & Technol, Sch Energy, Xian 710054, Shaanxi, Peoples R China
关键词
D O I
10.1088/1755-1315/647/1/012079
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Taking a typical two-person office as the research object, the indoor thermal comfort of the radiant cooling-displacement ventilation air-conditioning, the radiant cooling-personalized air-supply air-conditioning, and the all-air air-conditioning were simulated and studied, and the indoor thermal comfort index properties was analyzed. It was found that the indoor personnel activity area with radiant cooling-personalized air-conditioning had the lowest air supply temperature, PMV and PPD, and the air supply speed met the requirements. The thermal comfort effect of the human body is significantly better than that of the other two air-conditioning, which provides a reference for the design, promotion and application of the new air-conditioning of radiant cooling and personalized air supply combined cooling in actual projects.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] PROCESS AND COMFORT AIR-CONDITIONING INSTALLATION
    不详
    [J]. REFRIGERATION AND AIR CONDITIONING, 1973, 76 (904): : 37 - &
  • [22] A novel integrated index for simultaneous evaluation of the thermal comfort and energy efficiency of air-conditioning systems
    Yang, Zixu
    Du, Chenqiu
    Xiao, Hansong
    Li, Baizhan
    Shi, Wenxing
    Wang, Baolong
    [J]. JOURNAL OF BUILDING ENGINEERING, 2022, 57
  • [23] Change of thermal comfort of student by installation of air-conditioning system in a classroom
    Ishii, Jin
    Kurazumi, Yoshihito
    Fukagawa, Kenta
    Hiramatsu, Shoutaro
    [J]. Journal of Environmental Engineering, 2008, 73 (623) : 23 - 29
  • [24] Ceiling-fan-integrated air-conditioning: thermal comfort evaluations
    Luo, Maohui
    Zhang, Hui
    Wang, Zi
    Arens, Edward
    Chen, Wenhua
    Bauman, Fred S.
    Raftery, Paul
    [J]. BUILDINGS & CITIES, 2021, 2 (01): : 928 - 951
  • [25] Thermal comfort and energy saving of a personalized PFCU air-conditioning system
    Pan, CS
    Chiang, HC
    Yen, MC
    Wang, CC
    [J]. ENERGY AND BUILDINGS, 2005, 37 (05) : 443 - 449
  • [26] Energy saving and thermal comfort studies of a regional air-conditioning mechanism
    Huang, K. D.
    Tuan, N. A.
    Shih, Y. C.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2010, 224 (A1) : 13 - 22
  • [27] A direct load control of air-conditioning loads with thermal comfort control
    Chu, CM
    Jong, TL
    Huang, YW
    [J]. 2005 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS, 1-3, 2005, : 664 - 669
  • [28] Analysis of Indoor Thermal Environment and Air-Conditioning Mode of Ventilation in Large Space Building
    Wu, Guozhong
    Xue, Kang
    Wang, Jing
    Li, Dong
    [J]. COMPUTER SCIENCE FOR ENVIRONMENTAL ENGINEERING AND ECOINFORMATICS, PT 2, 2011, 159 : 467 - 471
  • [29] AIR-CONDITIONING FOR PRIVATE INDOOR POOLS
    PIELKE, R
    [J]. KALTE UND KLIMATECHNIK, 1979, 32 (03): : 114 - &
  • [30] Optimization of fresh air conditioning system for indoor thermal comfort and air quality
    [J]. Yang, P. (yang_peizhi@csu.edu.cn), 1600, Sila Science, University Mah Mekan Sok, No 24, Trabzon, Turkey (31):