Design and performances of immunoassay based on SPR biosensor with magnetic microbeads

被引:56
|
作者
Sun, Ying [1 ]
Bai, Yuping [1 ]
Song, Daqian [1 ]
Li, Xiaozhou [1 ]
Wang, Uying [1 ]
Zhang, Hanqi [1 ]
机构
[1] Jilin Univ, Coll Chem, Changchun 130012, Peoples R China
来源
BIOSENSORS & BIOELECTRONICS | 2007年 / 23卷 / 04期
关键词
surface plasmon resonance; conjugates; magnetic microbeads; heat shock protein 70; SURFACE-PLASMON RESONANCE; SENSITIVITY ENHANCEMENT; HIGH-RESOLUTION; SENSORS; ANTIBODIES; IMMUNOSENSOR; BINDING; DNA;
D O I
10.1016/j.bios.2007.06.016
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A surface plasmon resonance (SPR) biosensor system was developed for immunoassay, based on the conjugates of magnetic microbeads coupling with antibody which could be trapped on the Au film firmly due to the magnetic force. The magnetic microbeads were used as the solid support for the heat shock protein 70 (Hsp 70) antibody and antibody immobilized magnetic microbeads were utilized instead of the single antibody for the determination of Hsp 70. Since the magnetic bead is coated with dextran, the antibodies and some specific biomolecular receptors can be immobilized using a variety of chemical reactions. Compared to traditional antibody immobilization on the sensing film, there is not a covalent link between the Au film and the antibody. There is a great advantage in that sensor can be stripped and reused, and the same chemistry used to derivative dextran-coated SPR sensors can be used for the magnetic bead-coated sensors. The sensing layer was formed well. Different dilution ratios (v/v) of the conjugates result in different detectable ranges. When the dilution ratios of the conjugate are 1: 10 and 1:5, the lowest concentrations of Hsp 70 that can be detected are 1.50 and 0.30 mu g ml(-1), respectively. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:473 / 478
页数:6
相关论文
共 50 条
  • [31] Comparative analysis for reflectivity of graphene based SPR biosensor
    Goutam Mohanty
    Bijay Kumar Sahoo
    Jamil Akhtar
    Optical and Quantum Electronics, 2015, 47 : 1911 - 1918
  • [32] Design and analysis of a dual-core PCF biosensor based on SPR for cancerous cells detection
    Majeed, Mohammed F.
    Ahmad, Ahmad K.
    OPTICAL AND QUANTUM ELECTRONICS, 2024, 56 (06)
  • [33] Design and Probing of Prism-Based SPR Nano-Biosensor for Human Sperm Detection
    Vasimalla, Yesudasu
    Kaur, Baljinder
    Maloji, Suman
    Kumar, Santosh
    IEEE TRANSACTIONS ON NANOBIOSCIENCE, 2025, 24 (01) : 70 - 77
  • [34] SPR Based Biosensor for the Detection of Abnormal Growth of Tissues
    Chaitra, S.
    Veena, C.
    Rao, K. Srinivas
    Sharan, Preeta
    2017 INTERNATIONAL CONFERENCE ON NEXTGEN ELECTRONIC TECHNOLOGIES: SILICON TO SOFTWARE (ICNETS2), 2017, : 149 - 153
  • [35] SPR-based single nucleotide mismatch biosensor
    Milkani, Eftim
    Khaing, Aung M.
    Morais, Sergi
    Lambert, Christopher R.
    McGimpsey, W. Grant
    ANALYTICAL METHODS, 2011, 3 (01) : 122 - 132
  • [36] Comparative analysis for reflectivity of graphene based SPR biosensor
    Mohanty, Goutam
    Sahoo, Bijay Kumar
    Akhtar, Jamil
    OPTICAL AND QUANTUM ELECTRONICS, 2015, 47 (07) : 1911 - 1918
  • [37] A highly sensitive SPR biosensor based on a graphene oxide sheet modified with gold bipyramids, and its application to an immunoassay for rabbit IgG
    Qiong Wu
    Daqian Song
    Di Zhang
    Hua Zhang
    Yaying Ding
    Yong Yu
    Ying Sun
    Microchimica Acta, 2015, 182 : 1739 - 1746
  • [38] A highly sensitive SPR biosensor based on a graphene oxide sheet modified with gold bipyramids, and its application to an immunoassay for rabbit IgG
    Wu, Qiong
    Song, Daqian
    Zhang, Di
    Zhang, Hua
    Ding, Yaying
    Yu, Yong
    Sun, Ying
    MICROCHIMICA ACTA, 2015, 182 (9-10) : 1739 - 1746
  • [39] Construction of DNA sandwich electrochemical biosensor with nanoPbS and nanoAu tags on magnetic microbeads
    Du, Ping
    Li, Hongxia
    Cao, Wei
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (11): : 3223 - 3228
  • [40] Design and analysis of birefringent SPR based PCF biosensor with ultra-high sensitivity and low loss
    Islam, Mohammad Rakibul
    Abu Jamil, Md
    Zaman, Md Siraz-Uz
    Ahsan, Syed Asir Hamim
    Pulak, Mahfuz Kabir
    Mehjabin, Fariha
    Khan, Md Moinul Islam
    Chowdhury, Jubair Alam
    Islam, Mohibul
    OPTIK, 2020, 221