A Machine Learning Method to Improve Non-Contact Heart Rate Monitoring Using an RGB Camera

被引:19
|
作者
Ghanadian, Hamideh [1 ]
Ghodratigohar, Mohammad [1 ]
Al Osman, Hussein [1 ]
机构
[1] Univ Ottawa, Ottawa, ON K1N 6N5, Canada
来源
IEEE ACCESS | 2018年 / 6卷
关键词
Blood volume pulse (BVP); independent component analysis (ICA); photoplethysmography (PPG); remote heart rate measurement; VITAL SIGNS; VIDEO;
D O I
10.1109/ACCESS.2018.2872756
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Recording and monitoring vital signs is an essential part of home-based healthcare. Using contact sensors to record physiological signals can cause discomfort to patients, especially after prolonged use. Hence, remote physiological measurement approaches have attracted considerable attention, as they do not require physical contact with the patient's skin. Several studies proposed techniques to measure heart rate (HR) and heart rate variability by detecting the blood volume pulse from human facial video recordings while the subject is in a resting condition. In this paper, we focus on the measurement of HR. We adopt an algorithm that uses the independent component analysis (ICA) to separate the source (physiological) signal from noise in the RGB channels of a facial video. We generalize existing methods to support subject movement during video recording. Furthermore, we improve the accuracy of existing methods by implementing a light equalization scheme to reduce the effect of shadows and unequal facial light on the HR estimation, a machine learning method to select the most accurate channel outputted by the ICA module, and a regression technique to adjust the initial HR estimate. With respect to the ECG measurement ground truth, the proposed method decreases the RMSE by 27% compared with the state of the art in the stationary condition. When the subject is in motion, our proposed method achieves an RMSE of 1.12 bpm.
引用
收藏
页码:57085 / 57094
页数:10
相关论文
共 50 条
  • [21] Non-contact monitoring of human respiration using infrared thermography and machine learning
    Jagadev, Preeti
    Giri, Lalat Indu
    INFRARED PHYSICS & TECHNOLOGY, 2020, 104
  • [22] Non-Contact Breathing Rate Estimation Using Machine Learning with an Optimized Architecture
    Brieva, Jorge
    Ponce, Hiram
    Moya-Albor, Ernesto
    MATHEMATICS, 2023, 11 (03)
  • [23] The Non-Contact Heart Rate Measurement System for Monitoring HRV
    Huang, Ji-Jer
    Yu, Sheng-, I
    Syu, Hao-Yi
    See, Aaron Raymond
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 3238 - 3241
  • [24] Uncertainty Measurements in Non-Contact Neonatal Heart Rate Monitoring
    Dosso, Yasmina Souley
    Greenwood, Kimberley J.
    Harrold, Joann
    Green, James R.
    IEEE ACCESS, 2023, 11 : 144168 - 144179
  • [25] Continuous non-contact respiratory rate and tidal volume monitoring using a Depth Sensing Camera
    Addison, Paul S.
    Smit, Philip
    Jacquel, Dominique
    Addison, Anthony P.
    Miller, Cyndy
    Kimm, Gardner
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (03) : 657 - 665
  • [26] Non-Contact HR Extraction from Different Color Spaces Using RGB Camera
    Panigrahi, Arpita
    Sharma, Hemant
    2022 NATIONAL CONFERENCE ON COMMUNICATIONS (NCC), 2022, : 332 - 337
  • [27] Non-Contact Oxygen Saturation Measurement Using YCgCr Color Space with an RGB Camera
    Kim, Na Hye
    Yu, Su-Gyeong
    Kim, So-Eui
    Lee, Eui Chul
    SENSORS, 2021, 21 (18)
  • [28] Non-Contact Monitoring of Breathing Pattern and Respiratory Rate via RGB Signal Measurement
    Massaroni, Carlo
    Lo Presti, Daniela
    Formica, Domenico
    Silvestri, Sergio
    Schena, Emiliano
    SENSORS, 2019, 19 (12)
  • [29] Non-Contact Heart Rate Estimation via Adaptive RGB/NIR Signal Fusion
    Kurihara, Kosuke
    Sugimura, Daisuke
    Hamamoto, Takayuki
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2021, 30 (30) : 6528 - 6543
  • [30] A Machine Learning Approach to Improve Contactless Heart Rate Monitoring Using a Webcam
    Monkaresi, Hamed
    Calvo, Rafael A.
    Yan, Hong
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2014, 18 (04) : 1153 - 1160