The Impact of Image Reconstruction Bias on PET/CT 90Y Dosimetry After Radioembolization

被引:3
|
作者
Walrand, Stephan [1 ]
Hesse, Michel [1 ]
Renaud, Lhommel [1 ]
Jamar, Francois [1 ]
机构
[1] Catholic Univ Louvain, B-1200 Brussels, Belgium
关键词
RADIOTHERAPY; PHANTOM;
D O I
10.2967/jnumed.114.152017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:494 / 495
页数:4
相关论文
共 50 条
  • [21] A multicentre comparison of quantitative 90Y PET/CT for dosimetric purposes after radioembolization with resin microspheres
    Willowson, Kathy P.
    Tapner, Michael
    Bailey, Dale L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (08) : 1202 - 1222
  • [22] PET versus CT to predict survival after the radioembolization of liver metastases with 90Y resin microspheres
    Guerriero, F.
    Cremonesi, M.
    Ferrari, M. E.
    Bonomo, G.
    Orsi, F.
    Colandrea, M.
    Marotta, G.
    De Cicco, C.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S380 - S381
  • [23] Impact of 90Y PET gradient-based tumor segmentation on voxel-level dosimetry in liver radioembolization
    Mikell, Justin K.
    Kaza, Ravi K.
    Roberson, Peter L.
    Younge, Kelly C.
    Srinivasa, Ravi N.
    Majdalany, Bill S.
    Cuneo, Kyle C.
    Owen, Dawn
    Devasia, Theresa
    Schipper, Matthew J.
    Dewaraja, Yuni K.
    EJNMMI PHYSICS, 2018, 5
  • [24] 90Y PET/CT quantitative accuracy and image quality
    Siman, Wendy
    Mawlawi, Osama
    Kappadath, Srinivas
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [25] Impact of image reconstruction method on dose distributions derived from 90Y PET images: phantom and liver radioembolization patient studies
    Hou, Xinchi
    Ma, Hillgan
    Esquinas, Pedro L.
    Uribe, Carlos
    Tolhurst, Stefano
    Benard, Francois
    Liu, David
    Rahmim, Arman
    Celler, Anna
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (21):
  • [26] Impact of 90Y PET gradient-based tumor segmentation on voxel-level dosimetry in liver radioembolization
    Justin K. Mikell
    Ravi K. Kaza
    Peter L. Roberson
    Kelly C. Younge
    Ravi N. Srinivasa
    Bill S. Majdalany
    Kyle C. Cuneo
    Dawn Owen
    Theresa Devasia
    Matthew J. Schipper
    Yuni K. Dewaraja
    EJNMMI Physics, 5
  • [27] A phantom and patient study of EUD in 90Y radioembolization: differences between 90Y PET/CT-based and true EUD, and sensitivity to reconstruction parameters.
    Mikell, Justin
    Dewaraja, Yuni
    Roberson, Peter
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [28] 90Y PET/CT quantitative accuracy and image quality
    Siman, Wendy
    Mawlawi, Osama
    Kappadath, Srinivas
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [29] High quality imaging and dosimetry for yttrium-90 (90Y) liver radioembolization using a SiPM-based PET/CT scanner
    Heying Duan
    Mohamed H. Khalaf
    Valentina Ferri
    Lucia Baratto
    Shyam M. Srinivas
    Daniel Y. Sze
    Andrei Iagaru
    European Journal of Nuclear Medicine and Molecular Imaging, 2021, 48 : 2426 - 2436
  • [30] High quality imaging and dosimetry for yttrium-90 (90Y) liver radioembolization using a SiPM-based PET/CT scanner
    Duan, Heying
    Khalaf, Mohamed H.
    Ferri, Valentina
    Baratto, Lucia
    Srinivas, Shyam M.
    Sze, Daniel Y.
    Iagaru, Andrei
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (08) : 2426 - 2436