Electrochemical activation of peroxides for treatment of contaminated water with landfill leachate: Efficacy, toxicity and biodegradability evaluation

被引:114
|
作者
Ghanbari, Farshid [1 ]
Wang, Qilin [2 ]
Hassani, Aydin [3 ]
Waclawek, Stanislaw [4 ]
Rodriguez-Chueca, Jorge [5 ]
Lin, Kun-Yi Andrew [6 ,7 ,8 ]
机构
[1] Abadan Fac Med Sci, Dept Environm Hlth Engn, Abadan, Iran
[2] Univ Technol Sydney, Ctr Technol Water & Wastewater, Sch Civil & Environm Engn, Ultimo, NSW 2007, Australia
[3] Near East Univ, Fac Engn, Dept Mat Sci & Nanotechnol Engn, Mersin 10, TR-99138 Nicosia, Trnc, Turkey
[4] Tech Univ Liberec, Inst Nanomat Adv Technol & Innovat, Studentska 1402-2, Liberec 46117 1, Czech Republic
[5] Univ Politecn Madrid UPM, Dept Ingn Quim Ind & Medio Ambiente, ETS Ingenieros Ind, C Jose Gutierrez Abascal 2, Madrid 28006, Spain
[6] Natl Chung Hsing Univ, Dept Environm Engn, 250 Kuo Kuang Rd, Taichung, Taiwan
[7] Natl Chung Hsing Univ, Innovat & Dev Ctr Sustainable Agr, 250 Kuo Kuang Rd, Taichung, Taiwan
[8] Natl Chung Hsing Univ, Res Ctr Sustainable Energy & Nano Technol, 250 Kuo Kuang Rd, Taichung, Taiwan
关键词
Landfill leachate; Electrochemical oxidation; Persulfate; Percarbonate; Hydrogen peroxide; Detoxification; WASTE-WATER; 2,4,5-TRICHLOROPHENOXYACETIC ACID; ADVANCED OXIDATION; HYDROGEN-PEROXIDE; BISPHENOL-A; DEGRADATION; REMOVAL; FENTON; ELECTROCOAGULATION; PRETREATMENT;
D O I
10.1016/j.chemosphere.2021.130610
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Contaminated water with landfill leachate (CWLL) with high salinity and high organic content (total organic carbon (TOC) = 649 mg/L and Chemical Oxygen Demand (COD) = 1175 mg/L) is a toxic and non-biodegradable effluent. The present research aimed to assess the treatment effectiveness of CWLL by electrocoagulation (EC)/oxidant process. The ferrous ions generated during the process were employed as coagulant and catalyst for the activation of different oxidants such as peroxymonosulfate (PMS), peroxydisulfate (PDS), hydrogen peroxide (HP), and percarbonate (PC) to decrease TOC in CWLL. Removal of ammonia, color, phosphorous, and chemical oxygen demand (COD) from CWLL effluent was explored at various processes. EC/HP had the best performance (similar to 73%) in mineralization of organic pollutants compared to others under the condition of pH 6.8, applied current of 200 mA, oxidant dosage of 6 mM, and time of 80 min. The oxidation priority was to follow this order: EC/HP > EC/PMS > EC/PDS > EC/PC. These processes enhanced the biodegradability of CWLL based on the average oxidation state and biochemical oxygen demand (BOD)/COD ratio. SUVA(254) and E-2/E-3 indices were also investigated on obtained effluents. The phytotoxicity evaluation was carried out based on the germination index, indicating that the electro-activated oxidant was an effective system to reduce the toxicity of polluted waters. EC/HP showed supremacy compared to others in terms of efficiency, cost, and detoxification. Therefore, the electro-activated oxidant system is a good means for removing organic pollutants from real wastewater. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Evaluation of membrane microfiltration fouling in landfill leachate treatment
    Pertile, Carine
    Zanini, Marcia
    Baldasso, Camila
    Andrade, Mara Zeni
    CristinaTessaro, Isabel
    MATERIA-RIO DE JANEIRO, 2018, 23 (01):
  • [42] WASTEWATER AND LANDFILL LEACHATE TESTING: ACUTE TOXICITY BIOTEST RESULTS EVALUATION
    Cetkauskaite, Anolda
    Vosyliene, Milda Zita
    Kazlauskiene, Nijole
    Kalciene, Virginija
    JOURNAL OF ENVIRONMENTAL ENGINEERING AND LANDSCAPE MANAGEMENT, 2016, 24 (02) : 143 - 156
  • [43] Evaluation of landfill leachate biodegradability using IOT through geotracking sensor based drone surveying
    Gopikumar, S.
    ENVIRONMENTAL RESEARCH, 2023, 236
  • [44] Leachate characterization and performance evaluation of leachate treatment plant in Cipayung landfill, Indonesia
    Noerfitriyani, E.
    Hartono, D. M.
    Moersidik, S. S.
    Gusniani, I
    4TH INTERNATIONAL SEMINAR ON SUSTAINABLE URBAN DEVELOPMENT, 2018, 106
  • [45] Application of multiple toxicity tests in monitoring of landfill leachate treatment efficiency
    Kalcikova, Gabriela
    Zupancic, Marija
    Levei, Erika Andrea
    Miclean, Mirela
    Englande, Andrew J.
    Gotvajn, Andreja Zgajnar
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2015, 187 (08)
  • [46] Application of multiple toxicity tests in monitoring of landfill leachate treatment efficiency
    Gabriela Kalčíková
    Marija Zupančič
    Erika Andrea Levei
    Mirela Miclean
    Andrew J. Englande
    Andreja Žgajnar Gotvajn
    Environmental Monitoring and Assessment, 2015, 187
  • [47] Orthogonal Experimental Study on the Treatment of Landfill Leachate Contaminated Groundwater by PRB Technology
    Xu Guang-quan
    Shi Hong-wei
    PROCEEDINGS OF 2010 INTERNATIONAL WORKSHOP ON DIFFUSE POLLUTION-MANAGEMENT MEASURES AND CONTROL TECHNIQUE, 2010, : 107 - +
  • [48] Electrochemical treatment of concentrate from reverse osmosis of sanitary landfill leachate
    Labiadh, Lazhar
    Fernandes, Annabel
    Ciriaco, Lurdes
    Pacheco, Maria Jose
    Gadri, Abdellatif
    Ammar, Salah
    Lopes, Ana
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2016, 181 : 515 - 521
  • [49] Treatment of landfill leachate by two-stage electrochemical combination technology
    Liu, Cui
    Li, Dong
    Li, Jiahui
    Zhao, Chengqian
    Liu, Xiaojing
    Huang, Xiao
    Yin, Feng
    Shi, Wei
    Yu, Jianghua
    Wu, Jun
    Lu, Jian
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2025, 13 (02):
  • [50] Technique for Advanced Electrochemical Oxidation Treatment of Nanofiltration Concentrate of Landfill Leachate
    XIONG Changgui
    LI Guang
    ZHANG Zhiliang
    XIA Zhengwu
    LI Jian
    YE Hongji
    Wuhan University Journal of Natural Sciences, 2014, 19 (04) : 355 - 360