Lock-in technique for precise measurement of ion distribution functions

被引:1
|
作者
Stetzkamp, Christian Luetke [1 ]
Tsankov, Tsanko Vaskov [1 ]
Czarnetzki, Uwe [1 ]
机构
[1] Ruhr Univ Bochum, Inst Plasma & Atom Phys, D-44780 Bochum, Germany
关键词
ion distribution function; retarding field energy analyzer; AC modulation technique; transfer function; ENERGY-DISTRIBUTION-FUNCTIONS; RETARDING-FIELD ANALYZER; COLLECTOR ANALYSIS; LANGMUIR-PROBE; RADIOFREQUENCY;
D O I
10.1088/1361-6463/abf8f1
中图分类号
O59 [应用物理学];
学科分类号
摘要
Retarding field energy analyzers are commonly used for the experimental determination of the distribution of ions. Measurements require taking the first derivative of the measured current with respect to the retarding voltage, which limits the accuracy of the results. Here a commercial energy analyzer is combined with a lock-in detection and AC modulation technique to obtain ion distribution functions with an improved dynamic range. The technical realization of the method together with its theoretical motivation are presented. The various challenges for implementing the technique and ways to address them are given. The energy resolution of the method is discussed based on the concept of transfer functions, and the influence of the various adjustable parameters (grid bias voltages, frequency and amplitude of the modulation signal) on the obtained results are studied. The application of the method to an inductive discharge readily shows a dynamic range of more than three orders of magnitude. This dynamic range provides information on additional plasma parameters, such as the potential and the plasma density at the sheath edge and in the center of the discharge. Possibilities for further improvement of the technique are discussed.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Lock-in frequency measurement with high precision and efficiency
    Lu, Jun
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (07):
  • [22] Photorefractive optical lock-in vibration spectral measurement
    Hale, TC
    Telschow, KL
    Deason, VA
    APPLIED OPTICS, 1997, 36 (31): : 8248 - 8258
  • [23] Lock-in technique for measuring friction on a nanometer scale
    Colchero, J
    Luna, M
    Baro, AM
    APPLIED PHYSICS LETTERS, 1996, 68 (20) : 2896 - 2898
  • [24] PRINCIPLES OF THE OPTIMUM LOCK-IN AVERAGING IN DLTS MEASUREMENT
    FERENCZI, G
    KISS, J
    ACTA PHYSICA ACADEMIAE SCIENTIARUM HUNGARICAE, 1981, 50 (03): : 285 - 290
  • [25] Lock-in amplifier in NIR reflectance measurement system
    Corluka, V.
    Filic, M.
    Valter, Z.
    Annals of DAAAM for 2005 & Proceedings of the 16th International DAAAM Symposium: INTELLIGENT MANUFACTURING & AUTOMATION: FOCUS ON YOUNG RESEARCHES AND SCIENTISTS, 2005, : 75 - 76
  • [26] Lock-in measurement of bio-impedance variations
    Min, M
    Märtens, O
    Parve, T
    MEASUREMENT, 2000, 27 (01) : 21 - 28
  • [27] A PRECISE TECHNIQUE FOR MEASUREMENT OF ROOTS AND ROOT DISTRIBUTION IN SOILS
    MELHUISH, FM
    ANNALS OF BOTANY, 1968, 32 (125) : 15 - &
  • [28] Application of digital lock-in technique in FEM instrument DAS
    Jilin University, Changchun 130026, China
    Yi Qi Yi Biao Xue Bao, 2006, 11 (1395-1398):
  • [29] FREQUENCY-FOLLOWING POTENTIALS IN MAN BY LOCK-IN TECHNIQUE
    EULER, M
    KIESSLING, J
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1981, 52 (05): : 400 - 404
  • [30] TECHNIQUE WITH LOCK-IN AMPLIFIER FOR REAL-TIME MEASUREMENT OF TRICUSPID-VALVE ANNULUS AREA
    TAMIYA, K
    HIGASHIDATE, M
    KIKKAWA, S
    AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 251 (02): : H236 - H241