Extreme responsiveness of the pupil of the dark-adapted mouse to steady retinal illumination

被引:0
|
作者
Pennesi, ME
Lyubarsky, AL
Pugh, EN
机构
[1] Univ Penn, Dept Psychol, Philadelphia, PA 19104 USA
[2] Univ Penn, Inst Neurol Sci, Philadelphia, PA 19104 USA
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. TO measure the dependence of the size of the pupils of mice on steady retinal illumination. METHODs. Anesthetized C57BL/6 mice aged 7 to 8 weeks were placed in a ganzfeld chamber in darkness, and in monochromatic (510 nm) and white light whose intensity was varied more than 6 log units. The pupils of the mice were photographed with an infrared video camera and recorded on videotape and the pupil areas determined by digital image analysis of the video recordings. RESULTS. Fully dark-adapted murine pupils had an area of 2.29 +/- 0.35 mm(2). The minimum pupil size at saturating intensity was 0.10 +/- 0.05 mm(2). The steady state pupil area declined to half its dark-adapted maximum when ganzfeld luminance was 10(-5) scotopic candela (scot. ed) per meter squared. Pupil area declined to 20% of the dark-adapted magnitude at approximately 10(-3) scot. cd/m(2). CONCLUSIONS. The mouse pupil can regulate retinal illumination by a factor exceeding 20. The neural circuitry that determines steady state murine pupil size is extremely sensitive to retinal illumination and under these experimental conditions is controlled almost exclusively by rod signals. This follows, because the ganzfeld illuminance (10(-5) scot, cd/m(2)) that causes the pupil to constrict to half its dark-adapted value corresponds to only approximately 0.01 photoisomerization per rod per second, whereas 80% reduction in pupil area occurs at approximately 1 photoisomerization per rod per sec. Based on this extreme responsiveness to steady illumination, the hypothesis is proposed that the murine pupil functions to protect a retinal circuit that can become saturated at extremely low photon capture rates. General principles of dark-adapted retinal circuitry support the identification of the first three neurons in the circuit as the rod, the rod bipolar, and the AII-amacrine. The rod and rod bipolar neurons do not approach saturation at the intensities at which the pupil constricts, however, and it seems unlikely that the AII-amacrine does. Thus the retinal neurons protected from saturation by the mouse pupil constrictions are probably ganglion cells with large receptive fields that have sustained responses.
引用
收藏
页码:2148 / 2156
页数:9
相关论文
共 50 条
  • [11] THE RETINAL ISOMER RATIO IN DARK-ADAPTED BACTERIORHODOPSIN REVISITED
    SCHERRER, P
    MATHEW, MK
    SPERLING, W
    STOECKENIUS, W
    BIOPHYSICAL JOURNAL, 1987, 51 (02) : A415 - A415
  • [12] Horizontal versus vertical dark-adapted pupil diameters in normal individuals
    Khanani, AM
    Archer, SM
    Brown, SM
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (12): : 2557 - 2558
  • [13] Dark-adapted Pupil Diameter as a Function of Age Measured With the NeurOptics Pupillometer
    Bradley, Jay C.
    Bentley, Karl C.
    Mughal, Aleem I.
    Bodhireddy, Hari
    Brown, Sandra M.
    JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (03) : 202 - 207
  • [14] The photovoltage of rods and cones in the dark-adapted mouse retina
    Cangiano, Lorenzo
    Asteriti, Sabrina
    Cervetto, Luigi
    Gargini, Claudia
    JOURNAL OF PHYSIOLOGY-LONDON, 2012, 590 (16): : 3841 - 3855
  • [15] The application of chromatic dark-adapted kinetic perimetry to retinal diseases
    Rotenstreich, Y
    Fishman, GA
    Lindeman, M
    Alexander, KR
    OPHTHALMOLOGY, 2004, 111 (06) : 1222 - 1227
  • [16] Simulation analysis of the retinal conformational equilibrium in dark-adapted bacteriorhodopsin
    Baudry, J
    Crouzy, S
    Roux, B
    Smith, JC
    BIOPHYSICAL JOURNAL, 1999, 76 (04) : 1909 - 1917
  • [17] The scotopic threshold response of the dark-adapted electroretinogram of the mouse
    Saszik, SM
    Robson, JG
    Frishman, LJ
    JOURNAL OF PHYSIOLOGY-LONDON, 2002, 543 (03): : 899 - 916
  • [18] The application of chromatic dark-adapted kinetic perimetry in retinal disease
    Rotenstreich, Y
    Fishman, GA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U48 - U48
  • [19] Comparison of 2 monocular pupillometers and an autorefractor for measurement of the dark-adapted pupil diameter
    Brown, Sandra M.
    Bradley, Jay C.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (04): : 660 - 664
  • [20] Dark-adapted pupil sizes in a prospective evaluation of laser in situ keratomileusis patients
    Schumer, DJ
    Bains, HS
    Brown, KL
    JOURNAL OF REFRACTIVE SURGERY, 2000, 16 (02) : S239 - S241