Advanced multiple beam equalization radiography: Receiver operating characteristic comparison with screen-film chest radiography

被引:0
|
作者
Swensen, SJ
Aughenbaugh, GL
Brown, LR
Harms, GF
Karsell, PR
Gray, JE
Ilstrup, DM
Hodge, DO
机构
[1] Mayo Clin & Mayo Fdn, Dept Diagnost Radiol, Rochester, MN 55905 USA
[2] Mayo Clin & Mayo Fdn, Biostat Sect, Rochester, MN 55905 USA
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To test the hypothesis that the advanced multiple beam equalization radiography (AMBER) imaging system is superior to conventional chest radiography in the demonstration of diffuse infiltrative lung disease, emphysema, pulmonary nodules, calcification within nodules, and mediastinal or hilar masses and lymphadenopathy. Material and Methods: The study involved 115 patients, each of whom underwent chest computed tomography (CT), AMBER, posteroanterior chest radiography, and conventional posteroanterior stereoscopic chest radiography (two films). All radiographs were obtained with the InSight Thoracic Imaging System. Four chest radiologists independently analyzed the 115 AMBER studies, 115 unpaired single conventional radiographs (a single film from a stereoscopic pair), and 115 stereoscopic conventional radiographs (2 films) for the presence of diffuse infiltrative lung disease, emphysema, pulmonary nodules, calcification within nodules, and mediastinal or hilar masses and lymphadenopathy, For each abnormality detected, the radiologists described their level of confidence based on a scale of 1 to 5, The 115 CT examinations were interpreted by consensus among 3 of the chest radiologists, The CT results were considered the standard. Receiver operating characteristic (ROC) techniques were used for statistical analysis. Results: No statistically significant differences were found with ROC techniques between the AMBER system and single or stereoscopic conventional screen-film radiography for the abnormalities studied. Conclusion: We noted no clinically significant difference between AMBER and either single or stereoscopic conventional screen-film radiography in this prospective study of 115 patients in which CT (performed within 1 week of both radiographic examinations) was the standard.
引用
收藏
页码:636 / 641
页数:6
相关论文
共 50 条
  • [21] FILM-BASED CHEST RADIOGRAPHY - AMBER VS ASYMMETRIC SCREEN-FILM SYSTEMS
    CHOTAS, HG
    FLOYD, CE
    RAVIN, CE
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (04) : 743 - 747
  • [22] FASTER SCREEN-FILM COMBINATIONS FOR CEPHALOMETRIC RADIOGRAPHY
    HURLBURT, CE
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1981, 52 (06): : 661 - 665
  • [23] SCREEN-FILM COMBINATIONS USED FOR CEPHALOMETRIC RADIOGRAPHY
    HURLBURT, C
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1978, 46 (05): : 721 - 724
  • [24] Chest radiography: Depiction of normal anatomy and pathologic structures with selenium-based digital radiography versus conventional screen-film radiography
    Woodard, PK
    Slone, RM
    Gierada, DS
    Reiker, GG
    Pilgram, TK
    Jost, RG
    RADIOLOGY, 1997, 203 (01) : 197 - 201
  • [25] COMPARISON OF STEREOSCOPICALLY ACQUIRED CHEST IMAGES BY USING STORAGE PHOSPHOR RADIOGRAPHY AND AN ASYMMETRIC SCREEN-FILM SYSTEM
    HARTMAN, TE
    AUGHENBAUGH, GL
    BROWN, LR
    HARMS, GF
    KARSELL, PR
    MILLER, WE
    RADIOLOGY, 1995, 197 : 341 - 341
  • [26] COMPARISON OF AN ULTRAVIOLET SCREEN-FILM SYSTEM WITH A RARE-EARTH SCREEN-FILM SYSTEM FOR USE IN PEDIATRIC RADIOGRAPHY
    CRUZ, BK
    YOUNGBLOOD, DD
    SWENSON, KN
    SHELTON, DK
    RADIOLOGY, 1992, 185 : 232 - 232
  • [27] COMPARISON OF STEREOSCOPICALLY ACQUIRED CHEST IMAGES WITH USE OF STORAGE PHOSPHOR RADIOGRAPHY AND AN ASYMMETRIC SCREEN-FILM SYSTEM
    HARTMAN, TE
    AUGHENBAUGH, GL
    BROWN, LR
    HARMS, GF
    KARSELL, PR
    MILLER, WE
    RADIOLOGY, 1995, 197 : 525 - 525
  • [28] Screen-film versus computed radiography imaging of the hand: A direct comparison
    Swee, RG
    Gray, JE
    Beabout, JE
    McLeod, RA
    Cooper, KL
    Bond, JR
    Wenger, DE
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (02) : 539 - 542
  • [29] DETECTION OF SUBTLE MICROCALCIFICATIONS - COMPARISON OF COMPUTED RADIOGRAPHY AND SCREEN-FILM MAMMOGRAPHY
    HIGASHIDA, Y
    MORIBE, N
    MORITA, K
    KATSUDA, N
    HATEMURA, M
    TAKADA, T
    TAKAHASHI, M
    YAMASHITA, J
    RADIOLOGY, 1992, 183 (02) : 483 - 486
  • [30] ADVANCED MULTIPLE-BEAM EQUALIZATION RADIOGRAPHY IN CHEST RADIOLOGY - A SIMULATED NODULE DETECTION STUDY
    KOOL, LJS
    BUSSCHER, DLT
    VLASBLOEM, H
    HERMANS, J
    VANDERMERWE, PC
    ALGRA, PR
    HERSTEL, W
    RADIOLOGY, 1988, 169 (01) : 35 - 39