Advanced multiple beam equalization radiography: Receiver operating characteristic comparison with screen-film chest radiography

被引:0
|
作者
Swensen, SJ
Aughenbaugh, GL
Brown, LR
Harms, GF
Karsell, PR
Gray, JE
Ilstrup, DM
Hodge, DO
机构
[1] Mayo Clin & Mayo Fdn, Dept Diagnost Radiol, Rochester, MN 55905 USA
[2] Mayo Clin & Mayo Fdn, Biostat Sect, Rochester, MN 55905 USA
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To test the hypothesis that the advanced multiple beam equalization radiography (AMBER) imaging system is superior to conventional chest radiography in the demonstration of diffuse infiltrative lung disease, emphysema, pulmonary nodules, calcification within nodules, and mediastinal or hilar masses and lymphadenopathy. Material and Methods: The study involved 115 patients, each of whom underwent chest computed tomography (CT), AMBER, posteroanterior chest radiography, and conventional posteroanterior stereoscopic chest radiography (two films). All radiographs were obtained with the InSight Thoracic Imaging System. Four chest radiologists independently analyzed the 115 AMBER studies, 115 unpaired single conventional radiographs (a single film from a stereoscopic pair), and 115 stereoscopic conventional radiographs (2 films) for the presence of diffuse infiltrative lung disease, emphysema, pulmonary nodules, calcification within nodules, and mediastinal or hilar masses and lymphadenopathy, For each abnormality detected, the radiologists described their level of confidence based on a scale of 1 to 5, The 115 CT examinations were interpreted by consensus among 3 of the chest radiologists, The CT results were considered the standard. Receiver operating characteristic (ROC) techniques were used for statistical analysis. Results: No statistically significant differences were found with ROC techniques between the AMBER system and single or stereoscopic conventional screen-film radiography for the abnormalities studied. Conclusion: We noted no clinically significant difference between AMBER and either single or stereoscopic conventional screen-film radiography in this prospective study of 115 patients in which CT (performed within 1 week of both radiographic examinations) was the standard.
引用
收藏
页码:636 / 641
页数:6
相关论文
共 50 条
  • [1] OPTIMIZATION OF CHEST FILMS OF EQUALIZATION RADIOGRAPHY (ADVANCED MULTIPLE-BEAM EQUALIZATION RADIOGRAPHY) - COMPARISON BY MEANS OF A RECEIVER OPERATING CHARACTERISTIC STUDY OF SIMULATED NODULAR INTERSTITIAL DISEASE
    KOOL, LJS
    VANPROOSDIJ, M
    VANMETTER, R
    VROOMAN, HA
    AARTS, NJ
    SHAW, PMPC
    OBERMANN, WR
    HEIJBOER, RJJ
    MEMEL, DS
    OESTMANN, JW
    INVESTIGATIVE RADIOLOGY, 1994, 29 (12) : 1020 - 1025
  • [2] Mixture distribution and receiver operating characteristic analysis of bedside chest imaging with screen-film and computed radiography
    Kundel, HL
    Polansky, M
    ACADEMIC RADIOLOGY, 1997, 4 (01) : 1 - 7
  • [3] Thin-section computed radiography of the chest: Comparison with conventional screen-film and beam-equalization techniques
    Randall, PA
    Vaughn, CJ
    Scalzetti, EM
    Wojtowycz, AR
    Groskin, SA
    Heitzman, ER
    RADIOLOGY, 1996, 201 : 340 - 340
  • [4] Comparison of an asymmetric screen-film combination with a conventional screen-film combination for chest radiography in 51 patients
    Greaney, T
    McCoy, C
    Masterson, J
    BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (837): : 929 - 932
  • [5] Comparison of subjective and objective evaluation of screen-film systems for chest radiography
    Moeckli, R
    Verdun, FR
    Bochud, FO
    Valley, JF
    Hessler, C
    Schnyder, P
    RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) : 265 - 268
  • [6] THRESHOLD PERCEPTION PERFORMANCE WITH COMPUTED AND SCREEN-FILM RADIOGRAPHY - IMPLICATIONS FOR CHEST RADIOGRAPHY
    DOBBINS, JT
    RICE, JJ
    BEAM, CA
    RAVIN, CE
    RADIOLOGY, 1992, 183 (01) : 179 - 187
  • [7] EVALUATION OF AN ASYMMETRIC SCREEN-FILM SYSTEM FOR CHEST RADIOGRAPHY
    MORISHITA, J
    MACMAHON, H
    DOI, K
    CARLIN, M
    SUKENOBU, Y
    MEDICAL PHYSICS, 1994, 21 (11) : 1769 - 1775
  • [8] EVALUATION OF ASYMMETRIC SCREEN-FILM SYSTEM FOR CHEST RADIOGRAPHY
    MORISHITA, J
    MACMAHON, H
    DOI, K
    RADIOLOGY, 1992, 185 : 250 - 250
  • [9] ALVEOLAR CONSOLIDATION DETECTION - ADVANCED MULTIPLE BEAM EQUALIZATION RADIOGRAPHY VERSUS CONVENTIONAL CHEST RADIOGRAPHY
    NICHOLS, RD
    GURNEY, JW
    JONES, KK
    ROBBINS, RA
    RENNARD, SI
    RADIOLOGY, 1993, 187 (01) : 65 - 69
  • [10] Computed radiography versus screen-film techniques for the detection of microcalcifications: A receiver operating characteristic study based on phantom images
    Shaw, CC
    King, JL
    Wang, T
    Breitenstein, DS
    Chang, TS
    RADIOLOGY, 1996, 201 : 347 - 347