Accuracy of near infrared spectroscopy in relation to precision of calibration data

被引:0
|
作者
Sorensen, LK [1 ]
机构
[1] Steins Lab, DK-6650 Brorup, Denmark
来源
关键词
infrared spectroscopy (accuracy; calibration data);
D O I
暂无
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
To obtain a more precise estimate of the accuracy of near infrared (NIR) spectroscopy in determination of total solids and fat in cheese, the measured standard error of prediction (SEP) should be corrected for imprecision of the reference method. High precision of reference data obtained through replicate analyses may not be the optimal goal in practice for the development and maintenance of calibration equations. In a situation of limited resources, it may be better to accept an increase in imprecision by reducing the number of replicate analyses for each sample and instead introducing additional samples. In the case here reported, it was possible to increase the standard deviation related to precision of reference data from 0.08 to 0.14% for total solids and from 0.08 to 0.16% for fat without any pronounced effect on the accuracy of NIR transmission spectroscopy in the calibration range 50-63% for total solids and 23-29% for fat. The mean SEPs were 0.19% for total solids and 0.18% for fat. if the standard deviation was increased from 0.08 to 0.32% for total solids and from 0.08% to 0.28% for fat, the mean absolute increases in SEPs were 0.02% for total solids and 0.03% for fat.
引用
收藏
页码:190 / 193
页数:4
相关论文
共 50 条
  • [31] Classification of Imbalanced Near-infrared Spectroscopy Data
    Wang, Qibin
    Li, Lingqiao
    Pan, Xipeng
    Yang, Huihua
    2020 12TH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTATIONAL INTELLIGENCE (ICACI), 2020, : 577 - 584
  • [32] EVALUATION OF PRECISION AND ACCURACY IN CALIBRATION OF HYDROPHONES
    BLUE, JE
    REPORT OF NRL PROGRESS, 1973, (MAR): : 33 - 33
  • [33] Functional Data Analysis for the Development of a Calibration Model for Near-infrared Data
    Jiang, Cheng
    Martin, Elaine B.
    18TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING, 2008, 25 : 683 - 688
  • [34] The accuracy of near-infrared spectroscopy in detection of subdural and epidural hematomas
    Kahraman, Serdar
    Kayali, Hakan
    Atabey, Cem
    Acar, Feridun
    Gocmen, Selcuk
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 61 (06): : 1480 - 1483
  • [35] Accuracy of Noninvasive Glucose Sensing Based on Near-Infrared Spectroscopy
    Liu, Jin
    Liu, Rong
    Xu, Kexin
    APPLIED SPECTROSCOPY, 2015, 69 (11) : 1313 - 1318
  • [36] High precision intelligent calibration device of visible/near-infrared integral sphere
    Lin, Guanyu, 1600, Chinese Society of Astronautics (43):
  • [37] Functional data analysis view of functional near infrared spectroscopy data
    Barati, Zeinab
    Zakeri, Issa
    Pourrezaei, Kambiz
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (11)
  • [39] CLASSIFICATION OF BRAZILIAN COFFEE USING NEAR-INFRARED SPECTROSCOPY AND MULTIVARIATE CALIBRATION
    Santos, Klecia M.
    Moura, Maria F. V.
    Azevedo, Francisco G.
    Lima, Kassio M. G.
    Raimundo, Ivo M., Jr.
    Pasquini, C.
    ANALYTICAL LETTERS, 2012, 45 (07) : 774 - 781
  • [40] Study of quantitative calibration model suitability in near-infrared spectroscopy analysis
    Xu, GT
    Yuan, HF
    Lu, WZ
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2001, 21 (04) : 459 - 463