Estimation of resting blood pressure using facial thermal images by separating acute stress variations

被引:10
|
作者
Iwashita, Yuki [1 ]
Nagumo, Kent [1 ]
Oiwa, Kosuke [1 ]
Nozawa, Akio [1 ]
机构
[1] Aoyama Gakuin Univ, Chuo Ku, 5-10-1 Fuchinobe, Sagamihara, Kanagawa, Japan
关键词
Facial thermal image; Independent component analysis; Resting blood pressure; INDEPENDENT COMPONENT ANALYSIS; CIRCADIAN-RHYTHM; ALGORITHM;
D O I
10.1007/s10015-021-00705-y
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
The increasing number of people with hypertension worldwide has become a matter of grave concern. Blood pressure monitoring using a non-contact measurement technique is expected to detect and control this medical condition. Previous studies have estimated blood pressure variations following an acute stress response based on facial thermal images obtained from infrared thermography devices. However, a non-contact resting blood pressure estimation method is required because blood pressure is generally measured in the resting state without inducing acute stress. Day-long blood pressure variations include short-term variations due to acute stress and long-term variations in circadian rhythms. The aim of this study is to estimate resting blood pressure from facial thermal images by separating and excluding short-term variations related to acute stress. To achieve this, short-term blood pressure variations components related to acute stress on facial thermal images were separated using independent component analysis. Resting blood pressure was estimated with the extracted independent components excluding the short-term components using multiple regression analysis. The results show that the proposed approach can accurately estimate resting blood pressure from facial thermal images, with a 9.90 mmHg root mean square error. In addition, features related to resting blood pressure were represented in the nose, lip, and cheek regions.
引用
收藏
页码:473 / 480
页数:8
相关论文
共 50 条
  • [21] Ocular blood flow responses to an acute decrease in blood pressure in resting humans
    Ikemura, Tsukasa
    Miyaji, Akane
    Hayashi, Naoyuki
    JOURNAL OF PHYSIOLOGICAL SCIENCES, 2013, 63 : S266 - S266
  • [22] Stress Recognition using Face Images and Facial Landmarks
    Jeon, Taejae
    Bae, Hanbyeol
    Lee, Yongju
    Jang, Sungjun
    Lee, Sangyoun
    2020 INTERNATIONAL CONFERENCE ON ELECTRONICS, INFORMATION, AND COMMUNICATION (ICEIC), 2020,
  • [23] VARIATIONS IN BLOOD-PRESSURE UNDER CONDITIONS OF STRESS
    FRANZ, IW
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1987, 112 (05) : 199 - 199
  • [24] Reducing the effect of face orientation using FaceMesh landmarks in drowsiness estimation based on facial thermal images
    Nomura, Ayaka
    Yoshida, Atsushi
    Nagumo, Kent
    Nozawa, Akio
    ARTIFICIAL LIFE AND ROBOTICS, 2025,
  • [25] Established and emerging personality constructs in behavioral cardiology: Associations with resting blood pressure and cardiovascular responses to acute stress
    Habra, ME
    Linden, W
    Anderson, JC
    PSYCHOSOMATIC MEDICINE, 2001, 63 (01): : 119 - 119
  • [26] Estimation of Human Emotions Using Thermal Facial Information
    Hung Nguyen
    Kotani, Kazunori
    Chen, Fan
    Le, Bac
    FIFTH INTERNATIONAL CONFERENCE ON GRAPHIC AND IMAGE PROCESSING (ICGIP 2013), 2014, 9069
  • [27] Human Pose Estimation Using Thermal Images
    Smith, Javier
    Loncomilla, Patricio
    Ruiz-Del-Solar, Javier
    IEEE ACCESS, 2023, 11 : 35352 - 35370
  • [28] Emotional Intensity Estimation using Thermal Images
    Rooj, Suparna
    Antesh, U.
    Bhattacharya, Shubhobrata
    Routray, Aurobinda
    Mandal, Manas K.
    IECON 2020: THE 46TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2020, : 459 - 464
  • [29] Inner ocular blood flow responses to an acute decrease in blood pressure in resting humans
    Ikemura, Tsukasa
    Kashima, Hideaki
    Yamaguchi, Yuji
    Miyaji, Akane
    Hayashi, Naoyuki
    PHYSIOLOGICAL MEASUREMENT, 2015, 36 (02) : 219 - 230
  • [30] Methods for reliable estimation of pulse transit time and blood pressure variations using smartphone sensors
    Dias, Alair, Jr.
    Murali, Srinivasan
    Rincon, Francisco
    Atienza, David
    MICROPROCESSORS AND MICROSYSTEMS, 2016, 46 : 84 - 95