Quantitative assessment of four-dimensional computed tomography image acquisition quality

被引:19
|
作者
Starkschall, George
Desai, Neil
Balter, Peter
Prado, Karl
Luo, Dershan
Cody, Dianna
Pan, Tinsu
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas, MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
来源
关键词
computed tomography; 4D imaging; image assessment; organ motion;
D O I
10.1120/jacmp.v8i3.2362
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of the present work was to describe the development and validation of a series of tests to assess the quality of four-dimensional ( 4D) computed-tomography ( CT) imaging as it is applied to radiation treatment planning. Using a commercial respiratory motion phantom and a programmable moving platform with a CT phantom, we acquired 4D CT datasets on two commercial multislice helical CT scanners that use different approaches to 4D CT image reconstruction. Datasets were obtained as the platform moved in various patterns designed to simulate breathing. Known inserts in the phantom were contoured, and statistics were generated to evaluate properties important to radiation therapy-namely, accuracy of phase-binning, shape, volume, and CT number. Phase-binning accuracy varied by as much as 5% for a 4D procedure in which images were reconstructed and then binned, but exhibited no variation for a 4D procedure in which projections were binned before reconstruction. The magnitude of geometric distortion was found to be small for both approaches, as was the magnitude of volume error. Partial-volume effects in the direction perpendicular to the transverse planes of reconstruction affected volume accuracy, however. Computed tomography numbers were reproduced accurately, but 4D images exhibited more variation in CT number than static CT images did. Characterization of such properties can be used to better understand and optimize the various parameters that affect 4D CT image quality.
引用
收藏
页码:1 / 20
页数:20
相关论文
共 50 条
  • [31] Both four-dimensional computed tomography and four-dimensional cone beam computed tomography under-predict lung target motion during radiotherapy
    Steiner, Elisabeth
    Shieh, Chun-Chien
    Caillet, Vincent
    Booth, Jeremy
    O'Brien, Ricky
    Briggs, Adam
    Hardcastle, Nicholas
    Jayamanne, Dasantha
    Szymura, Kathryn
    Eade, Thomas
    Keall, Paul
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 135 : 65 - 73
  • [32] Quantitative analysis of metacarpophalangeal joints during active flexion using four-dimensional computed tomography
    Ishii, Kazunori
    Oki, Satoshi
    Iwamoto, Takuji
    Jinzaki, Masahiro
    Nagura, Takeo
    Matsumoto, Morio
    Nakamura, Masaya
    [J]. CLINICAL BIOMECHANICS, 2020, 80
  • [33] Improved Cine Four-Dimensional Computed Tomography (4D CT) Acquisition and Processing Method
    Castillo, S.
    Castillo, R.
    Castillo, E.
    Pan, T.
    Ibbott, G.
    Balter, P.
    Hobbs, B.
    Dai, J.
    Guerrero, T.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 573 - 573
  • [34] Performance studies of four-dimensional cone beam computed tomography
    Qi, Zhihua
    Chen, Guang-Hong
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (20): : 6709 - 6721
  • [35] QUANTIFICATION OF ARTIFACT REDUCTION WITH REAL-TIME CINE FOUR-DIMENSIONAL COMPUTED TOMOGRAPHY ACQUISITION METHODS
    Langner, Ulrich W.
    Keall, Paul J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (04): : 1242 - 1250
  • [36] Parathyroid Imaging Four-dimensional Computed Tomography, Sestamibi, and Ultrasonography
    Strauss, Sara B.
    Roytman, Michelle
    Phillips, C. Douglas
    [J]. NEUROIMAGING CLINICS OF NORTH AMERICA, 2021, 31 (03) : 379 - 395
  • [37] Four-dimensional Computed Tomography for Preoperative Localization of Parathyroid Adenomas
    Zeina, Abdel-Rauf
    Nakar, Helit
    Reindorp, Nadir
    Nachtigal, Alicia
    Krausz, Michael M.
    Ashkenazi, Itamar
    Shapira-Rootman, Mika
    [J]. ISRAEL MEDICAL ASSOCIATION JOURNAL, 2017, 19 (04): : 216 - 220
  • [38] Four-dimensional computed tomography and detection of dynamic capitate subluxation
    Repse, Stephen E.
    Amis, Benjamin
    Troupis, John M.
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2015, 59 (03) : 331 - 335
  • [39] A Four-Dimensional Computed Tomography Analysis of Multiorgan Abdominal Motion
    Hallman, Joshua L.
    Mori, Shinichiro
    Sharp, Gregory C.
    Lu, Hsiao-Ming
    Hong, Theodore S.
    Chen, George T. Y.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (01): : 435 - 441
  • [40] Motion artifact detection in four-dimensional computed tomography images
    Bouilhol, G.
    Ayadi, M.
    Pinho, R.
    Rit, S.
    Sarrut, D.
    [J]. XVII INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY (ICCR 2013), 2014, 489