Extraction Induced by Emulsion Breaking for Ca, Cu, Fe, Mn, Ni, and Zn Determination in Chocolate by Flame Atomic Absorption Spectrometry

被引:8
|
作者
Bakircioglu, Dilek [1 ]
Kurtulus, Yasemin Bakircioglu [1 ]
Topraksever, Nukte [1 ]
机构
[1] Trakya Univ, Fac Sci, Dept Chem, Edirne, Turkey
关键词
LIQUID-LIQUID MICROEXTRACTION; EDIBLE OILS; CRUDE-OIL; SAMPLES; METALS; DIGESTION; ZINC; CD; MICROWAVE; NICKEL;
D O I
10.1093/jaoacint/qsac048
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background Chocolate is a rich source of essential and non-essential elements. A new liquid-liquid extraction (LLE) approach, extraction induced by emulsion breaking (EIEB), is proposed in which the analyzed elements are transferred from the organic phase to the aqueous phase before measurement by flame atomic absorption spectrometry (FAAS). Objective To compare EIEB to microwave digestion (MWD) for extraction of elements from chocolate prior to FAAS. Methods EIEB parameters were varied to optimize the procedure. EIEB-FAAS was then compared to MWD-FAAS for the analysis of Ca, Cu, Fe, Mn, Ni, and Zn in milk and dark chocolate samples. A certified reference material (NIST 2384, baking chocolate) was analyzed to determine the recoveries of Ca, Cu, Fe, Mn, and Zn by the two methods. Results The optimized EIEB extraction method involves dilution of tempered chocolate with toluene, ultrasonic emulsification with acidified Triton X-114, breaking the emulsion by heating, and centrifugation to produce two well-defined phases. Analysis of dark and milk chocolate samples showed similar repeatability by EIEB-FAAS (RSDr 0.3 to 6.6% in dark and 0.5 to 8.7% in milk) and MWD-FAAS (RSDr 0.5 to 5.4% in dark and 0.7 to 10.2% in milk), with no significant difference detected between the methods for analysis of Ca, Cu, Fe, Mn, Ni, and Zn based on Student's t-test. Analysis of NIST 2384 baking chocolate certified reference material for Ca, Cu, Fe, Mn, and Zn demonstrated recoveries of 98.6 to 99.5% for EIEB-FAAS compared to 95.8 to 98.6% for MWD-FAAS. Conclusion EIEB-FAAS was shown to provide high recovery and excellent repeatability for accurate determination of Ca, Cu, Fe, Mn, Ni, and Zn from dark and milk chocolates.
引用
下载
收藏
页码:1299 / 1308
页数:10
相关论文
共 50 条
  • [21] Continuous determination of Zn, Cu and Mn in tea by flame atomic absorption spectrophotometry
    Ma, G
    Zhang, JY
    Chen, WM
    Han, JX
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 1999, 19 (03) : 408 - 410
  • [22] Extraction method based on emulsion breaking for the determination of Cu, Fe and Pb in Brazilian automotive gasoline samples by high-resolution continuum source flame atomic absorption spectrometry
    Leite, Clarice C.
    de Jesus, Alexandre
    Kolling, Leandro
    Ferrao, Marco F.
    Samios, Dimitrios
    Silva, Marcia M.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 142 : 62 - 67
  • [23] DETERMINATION OF CD, CU, PB, ZN AND MN IN GRASSES BY FLAME ATOMIC-ABSORPTION SPECTROMETRY - MINERALIZATION EFFECTS
    HOENIG, M
    VANDERSTAPPEN, R
    ANALUSIS, 1978, 6 (07) : 312 - 316
  • [24] Extraction of Cu, Fe, Mn, and Ni from Margarine Samples Using Extraction Induced by Emulsion Breaking Procedure Prior to Graphite Furnace Atomic Absorption Spectrometry and Comparison of Results to Provisional Tolerable Daily Intake Values
    Kurtulus, Yasemin Bakircioglu
    Bakircioglu, Dilek
    Babac, Alper Can
    Yurtsever, Selcuk
    Topraksever, Nukte
    JOURNAL OF AOAC INTERNATIONAL, 2020, 103 (05) : 1256 - 1263
  • [25] Extraction of Cu, Fe, Mn, and Ni from margarine samples using extraction induced by emulsion breaking procedure prior to graphite furnace atomic absorption spectrometry and comparison of results to provisional tolerable daily intake values
    Kurtulus Y.B.
    Bakircioglu D.
    Babac A.C.
    Yurtsever S.
    Topraksever N.
    Journal of AOAC International, 2021, 103 (05) : 1256 - 1263
  • [26] EXTRACTION-FLAME ATOMIC-ABSORPTION DETERMINATION OF MICROTRACES OF AG, BI, CD, CO, CU, FE, MN, NI, PB AND ZN IN AMMONIUM-SULFATE
    IVANOVA, E
    HAVEZOV, I
    VRACHEVA, N
    JORDANOV, N
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1985, 320 (02): : 133 - 136
  • [27] Extraction induced by emulsion breaking as a tool for Ca and Mg determination in biodiesel by fast sequential flame atomic absorption spectrometry (FS-FAAS) using Co as internal standard
    Pereira, Fernanda M.
    Brum, Daniel M.
    Lepri, Fabio G.
    Cassella, Ricardo J.
    MICROCHEMICAL JOURNAL, 2014, 117 : 172 - 177
  • [28] Application of the extraction induced by emulsion breaking for the determination of chromium and manganese in edible oils by electrothermal atomic absorption spectrometry
    Robaina, Nicolle F.
    Brum, Daniel M.
    Cassella, Ricardo J.
    TALANTA, 2012, 99 : 104 - 112
  • [29] Determination of the Hydrophobic Fraction of Ca, Fe, Mg and Zn in Dark Color Honeys Using Solid Phase Extraction and Flame Atomic Absorption Spectrometry
    Pohl, Pawel
    Stecka, Helena
    Greda, Krzysztof
    Jamroz, Piotr
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2012, 23 (06) : 1098 - 1103
  • [30] Direct Determination of Cd, Co, Cu, Fe, Mn, Na, Ni, Pb, and Zn in Ethanol Fuel by High-Resolution Continuum Source Flame Atomic Absorption Spectrometry
    Leite, Clarice C.
    de Jesus, Alexandre
    Potes, Mariana L.
    Vieira, Mariana A.
    Samios, Dimitrios
    Silva, Marcia M.
    ENERGY & FUELS, 2015, 29 (11) : 7358 - 7363