Experimental investigation on concrete-filled corrugated steel tubular column under constant axial load and cyclic load

被引:24
|
作者
Fang, Yong [1 ,2 ]
Wang, Yuyin [1 ,2 ]
Elchalakani, Mohamed [3 ]
Yang, Hua [1 ,2 ]
机构
[1] Harbin Inst Technol, Key Lab Struct Dynam Behav & Control, Minist Educ, Harbin 150090, Peoples R China
[2] Harbin Inst Technol, Sch Civil Engn, Campus 2,Huanghe Rd 73, Harbin 150090, Heilongjiang, Peoples R China
[3] Univ Western Australia, Fac Engn Comp & Math Sci, Dept Civil Environm & Min Engn, Nedlands, WA, Australia
基金
中国国家自然科学基金;
关键词
Concrete-filled corrugated steel tube; Concrete-filled steel tube; Cyclic load; Confinement; Seismic behaviour; STRESS-STRAIN MODEL; FRP-CONFINED CONCRETE; HIGH-STRENGTH STEEL; RC BRIDGE COLUMNS; SEISMIC BEHAVIOR; STUB COLUMNS; DESIGN; COMPRESSION; TUBES; CAPACITY;
D O I
10.1016/j.engstruct.2021.113245
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Concrete-filled corrugated steel tubular (CFCST) structure is a novel composite member with significant potential serving as an offshore bridge pier or a sub-sea underground column. The anti-corrosive galvanized corrugated steel tube (CST) is versatilely utilized as a peripheral protecting shell, an external restraint material for the concrete, and a permanent formwork. A considerable body of preliminary experimental and numerical work has been conducted on the static performance of CFCST, however the investigations of its seismic behaviour are rather limited. This paper therefore presents experimental investigations on CFCST columns subjected to con-stant axial load and cyclic load. The designs and fabrications of the test setup are introduced in detail. With the discussion of failure modes, hysteretic curves, ductility, energy dissipation capacity, and stiffness degradation, the seismic behaviour of CFCST are studied comparatively. The test results indicate that the seismic behaviour of CFCST is more competitive than that of conventional RC columns while similar to those of TRC columns. With the increase of axial compression ratio, the lateral load was increased but the deformability was reduced. Both the strength and ductility of CFCST can be improved with the increase of confinement factor. The analysis of non-uniformly distributed strain of CST indicates that the loading paths do not affect the work mechanism of CST. The CST mainly provides transverse confinement and its contribution to flexural capacity was negligible. The modified equations can be roughly employed to predict the N -M interaction relationships of the CFCST columns. More experimental or numerical work should be conducted in the future to further evaluate the seismic behaviour of CFCST quantitatively.
引用
收藏
页数:23
相关论文
共 50 条
  • [31] Experimental Research on Static Behavior of Stiffened Square Concrete-filled Steel Tubular Columns Subjected to Axial Load
    Yang Yuanlong
    Zhang Jingshu
    Wang Yuyin
    APPLIED MECHANICS AND MATERIALS I, PTS 1-3, 2013, 275-277 : 1049 - +
  • [32] Experimental investigation on seismic behaviour of concrete-filled corrugated steel tubes under cyclic torsional loads
    Fang, Yong
    Yang, Hua
    Chan, Takming
    Wang, Yuyin
    ENGINEERING STRUCTURES, 2024, 309
  • [33] Stress concentration factor in concrete-filled steel tubular K-joints under balanced axial load
    Musa, Idris A.
    Mashiri, Fidelis R.
    THIN-WALLED STRUCTURES, 2019, 139 : 186 - 195
  • [34] Mechanical behavior of concrete-filled round-ended steel tubular stub columns under axial load
    Gu, Li-Xiong
    Ding, Fa-Xing
    Fu, Lei
    Li, Gang
    Zhongguo Gonglu Xuebao/China Journal of Highway and Transport, 2014, 27 (01): : 57 - 63
  • [35] Experimental research on concrete-filled RPC tubes under axial compression load
    Shan, Bo
    Lai, Da-De
    Xiao, Yan
    Luo, Xiao-Bing
    ENGINEERING STRUCTURES, 2018, 155 : 358 - 370
  • [36] Behavior of concrete-filled steel tubular column at large axial deformation
    Qi, Hong-Hui
    Li, Guo-Qiang
    Lou, Guo-Biao
    Structures, 2024, 70
  • [37] Axial load behavior of stiffened concrete-filled steel columns
    Huang, CS
    Yeh, YK
    Liu, GY
    Hu, HT
    Tsai, KC
    Weng, YT
    Wang, SH
    Wu, MH
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2002, 128 (09): : 1222 - 1230
  • [38] Experimental study on axial performance of concrete-filled steel tubular stub column under salt spray corrosion
    Gao S.
    Peng Z.
    Guo L.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2019, 40 : 214 - 219
  • [39] Experimental investigation into FRP-confined concrete-filled steel tubular columns under axial compression
    Ma, Lu
    Zhou, Changlin
    Zhang, Ji
    MAGAZINE OF CONCRETE RESEARCH, 2023, 75 (03) : 109 - 122
  • [40] EXPERIMENTAL STUDY OF CONCRETE-FILLED STEEL TUBULAR ARCHES WITH CORRUGATED STEEL WEBS
    Gao, Jing
    Su, Jiazhan
    Xia, Yong
    Chen, Baochun
    ADVANCED STEEL CONSTRUCTION, 2014, 10 (01): : 99 - 115